These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

138 related articles for article (PubMed ID: 38195144)

  • 1. Evaluation of Optimal Esophageal Catheter Balloon Inflation Volume in Mechanically Ventilated Children.
    Rudolph MW; Koopman AA; Blokpoel RGT; Kneyber MCJ
    Respir Care; 2024 Feb; 69(3):325-332. PubMed ID: 38195144
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Measurements Obtained From Esophageal Balloon Catheters Are Affected by the Esophageal Balloon Filling Volume in Children With ARDS.
    Hotz JC; Sodetani CT; Van Steenbergen J; Khemani RG; Deakers TW; Newth CJ
    Respir Care; 2018 Feb; 63(2):177-186. PubMed ID: 29089460
    [TBL] [Abstract][Full Text] [Related]  

  • 3. The calibration of esophageal pressure by proper esophageal balloon filling volume: A clinical study.
    Jiang J; Su L; Cheng W; Wang C; Rui X; Tang B; Zhang H; He H; Long Y
    Front Med (Lausanne); 2022; 9():986982. PubMed ID: 36606053
    [TBL] [Abstract][Full Text] [Related]  

  • 4. In vivo calibration of esophageal pressure in the mechanically ventilated patient makes measurements reliable.
    Mojoli F; Iotti GA; Torriglia F; Pozzi M; Volta CA; Bianzina S; Braschi A; Brochard L
    Crit Care; 2016 Apr; 20():98. PubMed ID: 27063290
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Use of esophageal balloon pressure-volume curve analysis to determine esophageal wall elastance and calibrate raw esophageal pressure: a bench experiment and clinical study.
    Sun XM; Chen GQ; Huang HW; He X; Yang YL; Shi ZH; Xu M; Zhou JX
    BMC Anesthesiol; 2018 Feb; 18(1):21. PubMed ID: 29444644
    [TBL] [Abstract][Full Text] [Related]  

  • 6. [Feasibility of using esophageal balloon pressure-volume curve to calibrate esophageal pressure during assisted mechanical ventilation].
    Sun X; Chen G; Yang Y; Zhou J
    Zhonghua Wei Zhong Bing Ji Jiu Yi Xue; 2020 Jul; 32(7):808-813. PubMed ID: 32788014
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Liquid- and air-filled catheters without balloon as an alternative to the air-filled balloon catheter for measurement of esophageal pressure.
    Beda A; Güldner A; Carvalho AR; Zin WA; Carvalho NC; Huhle R; Giannella-Neto A; Koch T; de Abreu MG
    PLoS One; 2014; 9(9):e103057. PubMed ID: 25247308
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Esophageal and transpulmonary pressures in acute respiratory failure.
    Talmor D; Sarge T; O'Donnell CR; Ritz R; Malhotra A; Lisbon A; Loring SH
    Crit Care Med; 2006 May; 34(5):1389-94. PubMed ID: 16540960
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Mechanical Ventilation Guided by Uncalibrated Esophageal Pressure May Be Potentially Harmful.
    Cammarota G; Lauro G; Santangelo E; Sguazzotti I; Perucca R; Verdina F; Boniolo E; Tarquini R; Bignami E; Mongodi S; Arisi E; Orlando A; Della Corte F; Vaschetto R; Mojoli F
    Anesthesiology; 2020 Jul; 133(1):145-153. PubMed ID: 32349074
    [TBL] [Abstract][Full Text] [Related]  

  • 10. The occlusion tests and end-expiratory esophageal pressure: measurements and comparison in controlled and assisted ventilation.
    Chiumello D; Consonni D; Coppola S; Froio S; Crimella F; Colombo A
    Ann Intensive Care; 2016 Dec; 6(1):13. PubMed ID: 26868503
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Inspiratory capacity at inflation hold in ventilated newborns: a surrogate measure for static compliance of the respiratory system.
    Hentschel R; Semar N; Guttmann J
    Pediatr Crit Care Med; 2012 Sep; 13(5):560-7. PubMed ID: 22460774
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Oesophageal balloon calibration during pressure support ventilation: a proof of concept study.
    Cammarota G; Verdina F; Santangelo E; Lauro G; Boniolo E; Tarquini R; Spinelli E; Zanoni M; Garofalo E; Bruni A; Pesenti A; Della Corte F; Navalesi P; Vaschetto R; Mauri T
    J Clin Monit Comput; 2020 Dec; 34(6):1223-1231. PubMed ID: 31792760
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Detailed measurements of oesophageal pressure during mechanical ventilation with an advanced high-resolution manometry catheter.
    Persson P; Ahlstrand R; Gudmundsson M; de Leon A; Lundin S
    Crit Care; 2019 Jun; 23(1):217. PubMed ID: 31196203
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Esophageal Manometry and Regional Transpulmonary Pressure in Lung Injury.
    Yoshida T; Amato MBP; Grieco DL; Chen L; Lima CAS; Roldan R; Morais CCA; Gomes S; Costa ELV; Cardoso PFG; Charbonney E; Richard JM; Brochard L; Kavanagh BP
    Am J Respir Crit Care Med; 2018 Apr; 197(8):1018-1026. PubMed ID: 29323931
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Assessing respiratory function depends on mechanical characteristics of balloon catheters.
    Walterspacher S; Isaak L; Guttmann J; Kabitz HJ; Schumann S
    Respir Care; 2014 Sep; 59(9):1345-52. PubMed ID: 24381189
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Use of Cardiac Cycle Locating to Minimize the Influence of Cardiac Artifacts on Esophageal Pressure Measurement During Dynamic Occlusion Test.
    He X; Sun XM; Chen GQ; Yang YL; Shi ZH; Xu M; Zhou JX
    Respir Care; 2018 Feb; 63(2):169-176. PubMed ID: 29066585
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Estimation of transpulmonary driving pressure during synchronized mechanical ventilation using a single lower assist maneuver (LAM) in rabbits: a comparison to measurements made with an esophageal balloon.
    Liu L; Li HL; Lu C; Patel P; Wang D; Beck J; Sinderby C
    Crit Care; 2023 Aug; 27(1):325. PubMed ID: 37626372
    [TBL] [Abstract][Full Text] [Related]  

  • 18. The application of esophageal pressure measurement in patients with respiratory failure.
    Akoumianaki E; Maggiore SM; Valenza F; Bellani G; Jubran A; Loring SH; Pelosi P; Talmor D; Grasso S; Chiumello D; Guérin C; Patroniti N; Ranieri VM; Gattinoni L; Nava S; Terragni PP; Pesenti A; Tobin M; Mancebo J; Brochard L;
    Am J Respir Crit Care Med; 2014 Mar; 189(5):520-31. PubMed ID: 24467647
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Esophageal balloon calibration during Sigh: A physiologic, randomized, cross-over study.
    Cammarota G; Santangelo E; Lauro G; Verdina F; Boniolo E; De Vita N; Tarquini R; Spinelli E; Garofalo E; Bruni A; Zanoni M; Messina A; Pesenti A; Corte FD; Navalesi P; Vaschetto R; Mauri T
    J Crit Care; 2021 Feb; 61():125-132. PubMed ID: 33157308
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Optimal esophageal balloon volume for accurate estimation of pleural pressure at end-expiration and end-inspiration: an in vitro bench experiment.
    Yang YL; He X; Sun XM; Chen H; Shi ZH; Xu M; Chen GQ; Zhou JX
    Intensive Care Med Exp; 2017 Dec; 5(1):35. PubMed ID: 28770541
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.