BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

136 related articles for article (PubMed ID: 38202918)

  • 1. Assessment of the Smartpill, a Wireless Sensor, as a Measurement Tool for Intra-Abdominal Pressure (IAP).
    Soucasse A; Jourdan A; Edin L; Meunier E; Bege T; Masson C
    Sensors (Basel); 2023 Dec; 24(1):. PubMed ID: 38202918
    [No Abstract]   [Full Text] [Related]  

  • 2. A better understanding of daily life abdominal wall mechanical solicitation: Investigation of intra-abdominal pressure variations by intragastric wireless sensor in humans.
    Soucasse A; Jourdan A; Edin L; Gillion JF; Masson C; Bege T
    Med Eng Phys; 2022 Jun; 104():103813. PubMed ID: 35641077
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Optimizing working space in porcine laparoscopy: CT measurement of the effects of intra-abdominal pressure.
    Vlot J; Wijnen R; Stolker RJ; Bax K
    Surg Endosc; 2013 May; 27(5):1668-73. PubMed ID: 23239305
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Intra-abdominal pressure during endoscopic full-thickness resection comparing manual and automatic control insufflation: a block-randomized porcine study.
    Kamba S; Kobayashi M; Koizumi A; Ono S; Hara Y; Shimamoto N; Matsui H; Furuhashi H; Ohya TR; Tamai N; Nishikawa M; Nakajima K; Sumiyama K
    Surg Endosc; 2020 Apr; 34(4):1625-1633. PubMed ID: 31214802
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Optimizing working space in laparoscopy: CT measurement of the effect of pre-stretching of the abdominal wall in a porcine model.
    Vlot J; Wijnen R; Stolker RJ; Bax KN
    Surg Endosc; 2014 Mar; 28(3):841-6. PubMed ID: 24114517
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Evaluating intra-abdominal pressures in a porcine model of acute lung injury by using a wireless motility capsule.
    Rauch S; Johannes A; Zollhöfer B; Muellenbach RM
    Med Sci Monit; 2012 May; 18(5):BR163-6. PubMed ID: 22534697
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Noninvasive Assessment of Intra-Abdominal Pressure Using Ultrasound-Guided Tonometry: A Proof-of-Concept Study.
    Bloch A; Glas M; Kohler A; Baumann U; Jakob SM
    Shock; 2018 Dec; 50(6):684-688. PubMed ID: 29251669
    [TBL] [Abstract][Full Text] [Related]  

  • 8. [Visceral resorption of intra-abdominal insufflated carbon dioxide in swine].
    Blobner M; Bogdanski R; Jelen-Esselborn S; Henke J; Erhard W; Kochs E
    Anasthesiol Intensivmed Notfallmed Schmerzther; 1999 Feb; 34(2):94-9. PubMed ID: 10189522
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Safety and Suitability of the SmartPill® after Abdominal Surgery: Results of the Prospective, Two-Armed, Open-Label PIDuSA Trial.
    van Beekum CJ; Esmann A; Heinze F; von Websky MW; Stoffels B; Wehner S; Coenen M; Fimmers R; Randau TM; Kalff JC; Vilz TO
    Eur Surg Res; 2021; 62(2):88-96. PubMed ID: 33951660
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Effects of prolonged increased intra-abdominal pressure on gastrointestinal blood flow in pigs.
    Gudmundsson FF; Gislason HG; Dicko A; Horn A; Viste A; Grong K; Svanes K
    Surg Endosc; 2001 Aug; 15(8):854-60. PubMed ID: 11443466
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Optimizing working space in laparoscopy: CT measurement of the influence of small body size in a porcine model.
    Vlot J; Staals LM; Wijnen RM; Stolker RJ; Bax KN
    J Pediatr Surg; 2015 Mar; 50(3):465-71. PubMed ID: 25746709
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Wireless capsule motility: comparison of the SmartPill GI monitoring system with scintigraphy for measuring whole gut transit.
    Maqbool S; Parkman HP; Friedenberg FK
    Dig Dis Sci; 2009 Oct; 54(10):2167-74. PubMed ID: 19655250
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Modeling intra-abdominal volume and respiratory driving pressure during pneumoperitoneum insufflation-a patient-level data meta-analysis.
    Mazzinari G; Diaz-Cambronero O; Serpa Neto A; Martínez AC; Rovira L; Argente Navarro MP; Malbrain MLNG; Pelosi P; Gama de Abreu M; Hollmann MW; Schultz MJ
    J Appl Physiol (1985); 2021 Mar; 130(3):721-728. PubMed ID: 33357006
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Morpho-functional evaluation of small bowel using wireless motility capsule and video capsule endoscopy in patients with known or suspected Crohn's disease: pilot study.
    Yung D; Douglas S; Hobson AR; Giannakou A; Plevris JN; Koulaouzidis A
    Endosc Int Open; 2016 Apr; 4(4):E480-6. PubMed ID: 27092333
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Some cardiopulmonary effects of capnoperitoneum in anesthetized guinea pigs (Cavia porcellus): spontaneous ventilation versus intubation and mechanical ventilation.
    McCready JE; Sanchez A; Tisotti T; Beaufrère H
    Vet Anaesth Analg; 2023 Jan; 50(1):72-80. PubMed ID: 36435693
    [TBL] [Abstract][Full Text] [Related]  

  • 16. In Vitro Validation of a Novel Continuous Intra-Abdominal Pressure Measurement System (TraumaGuard).
    Tayebi S; Wise R; Zarghami A; Malbrain L; Khanna AK; Dabrowski W; Stiens J; Malbrain MLNG
    J Clin Med; 2023 Sep; 12(19):. PubMed ID: 37834904
    [No Abstract]   [Full Text] [Related]  

  • 17. Pressure Measurement Techniques for Abdominal Hypertension: Conclusions from an Experimental Model.
    Chopra SS; Wolf S; Rohde V; Freimann FB
    Crit Care Res Pract; 2015; 2015():278139. PubMed ID: 26113992
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Increased intra-abdominal pressure affects respiratory variations in arterial pressure in normovolaemic and hypovolaemic mechanically ventilated healthy pigs.
    Duperret S; Lhuillier F; Piriou V; Vivier E; Metton O; Branche P; Annat G; Bendjelid K; Viale JP
    Intensive Care Med; 2007 Jan; 33(1):163-71. PubMed ID: 17102964
    [TBL] [Abstract][Full Text] [Related]  

  • 19. SmartPill® as an objective parameter for determination of severity and duration of postoperative ileus: study protocol of a prospective, two-arm, open-label trial (the PIDuSA study).
    Vilz TO; Pantelis D; Lingohr P; Fimmers R; Esmann A; Randau T; Kalff JC; Coenen M; Wehner S
    BMJ Open; 2016 Jul; 6(7):e011014. PubMed ID: 27401360
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Modified extraperitoneal endoscopic separation of parts for abdominal compartment syndrome.
    Barnes GS; Papasavas PK; O'Mara MS; Urbandt J; Hayetian FD; Gagné DJ; Newton ED; Caushaj PF
    Surg Endosc; 2004 Nov; 18(11):1636-9. PubMed ID: 15931474
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.