BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

170 related articles for article (PubMed ID: 38217722)

  • 1. Outcome and complication rate of total hip arthroplasty in patients younger than twenty years: which bearing surface should be used?
    Kang SY; Ko YS; Kim HS; Yoo JJ
    Int Orthop; 2024 Jun; 48(6):1381-1390. PubMed ID: 38217722
    [TBL] [Abstract][Full Text] [Related]  

  • 2. What Is the Frequency of Fracture of Ceramic Components in THA? Results from the Norwegian Arthroplasty Register from 1997 to 2017.
    Hallan G; Fenstad AM; Furnes O
    Clin Orthop Relat Res; 2020 Jun; 478(6):1254-1261. PubMed ID: 32348085
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Do alumina matrix composite bearings decrease hip noises and bearing fractures at a minimum of 5 years after THA?
    Baek SH; Kim WK; Kim JY; Kim SY
    Clin Orthop Relat Res; 2015 Dec; 473(12):3796-802. PubMed ID: 26126991
    [TBL] [Abstract][Full Text] [Related]  

  • 4. High Risk of Neck-liner Impingement and Notching Observed with Thick Femoral Neck Implants in Ceramic-on-ceramic THA.
    Kim HS; Park JW; Lee SJ; Lee YK; Ha YC; Koo KH
    Clin Orthop Relat Res; 2022 Apr; 480(4):690-699. PubMed ID: 34699410
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Ceramic-on-ceramic THA associated with fewer dislocations and less muscle degeneration by preserving muscle progenitors.
    Hernigou P; Roussignol X; Delambre J; Poignard A; Flouzat-Lachaniette CH
    Clin Orthop Relat Res; 2015 Dec; 473(12):3762-9. PubMed ID: 26054482
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Ceramic-on-ceramic THA Implants in Patients Younger Than 20 Years.
    Hannouche D; Devriese F; Delambre J; Zadegan F; Tourabaly I; Sedel L; Chevret S; Nizard R
    Clin Orthop Relat Res; 2016 Feb; 474(2):520-7. PubMed ID: 26341897
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Mid-term Results of Revision Total Hip Arthroplasty Using Delta Ceramic-on-Ceramic Bearing.
    Lee YK; Ha YC; Won SJ; Kim JH; Park JW; Koo KH
    Clin Orthop Surg; 2023 Feb; 15(1):20-26. PubMed ID: 36778987
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Do the Reasons for Ceramic-on-ceramic Revisions Differ From Other Bearings in Total Hip Arthroplasty?
    Migaud H; Putman S; Kern G; Isida R; Girard J; Ramdane N; Delaunay CP; Hamadouche M;
    Clin Orthop Relat Res; 2016 Oct; 474(10):2190-9. PubMed ID: 27255729
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Fourth-Generation Ceramic-on-Ceramic THA in Patients with Ankylosing Spondylitis: A Minimum 10-Year Follow-Up.
    Li L; Fu J; Xu C; Ni M; Chai W; Hao L; Zhou Y; Chen J
    Orthop Surg; 2022 May; 14(5):860-867. PubMed ID: 35434922
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Same survival but higher rate of osteolysis for metal-on-metal Ultamet versus ceramic-on-ceramic in patients undergoing primary total hip arthroplasty after 8 years of follow-up.
    Higuchi Y; Seki T; Takegami Y; Komatsu D; Morita D; Ishiguro N
    Orthop Traumatol Surg Res; 2018 Dec; 104(8):1155-1161. PubMed ID: 30269967
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Comparison of cementless total hip arthroplasty survivorship between metal-on-highly cross-linked polyethylene and ceramic on ceramic bearings: A case control study with a 5-9-year follow-up.
    Higuchi Y; Seki T; Hasegawa Y; Morita D; Komatsu D; Takegami Y; Ishiguro N
    Orthop Traumatol Surg Res; 2018 Sep; 104(5):663-669. PubMed ID: 29902637
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Is the Survivorship of Birmingham Hip Resurfacing Better Than Selected Conventional Hip Arthroplasties in Men Younger Than 65 Years of Age? A Study from the Australian Orthopaedic Association National Joint Replacement Registry.
    Stoney J; Graves SE; de Steiger RN; Rainbird S; Kelly TL; Hatton A
    Clin Orthop Relat Res; 2020 Nov; 478(11):2625-2636. PubMed ID: 32898048
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Pigmented villonodular synovitis does not influence the outcome following cementless total hip arthroplasty using ceramic-on-ceramic articulation: a case-control study with middle-term follow-up.
    Xu C; Guo H; Bell KL; Kuo FC; Chen JY
    J Orthop Surg Res; 2018 Nov; 13(1):294. PubMed ID: 30458820
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Fourth-generation ceramic-on-ceramic THA results in improvements in midterm outcomes compared to third-generation THA but does not resolve noise problems: a cohort study of a single-hip system.
    Kim SC; Lim YW; Jo WL; Park HW; Han SB; Kwon SY; Kim YS
    BMC Musculoskelet Disord; 2019 May; 20(1):263. PubMed ID: 31142296
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Squeaking Is Common and Increases Over Time Among Patients With Long-term Follow-up After Ceramic-on-ceramic THA.
    Taniguchi K; Quacinella M; Barlow B
    Clin Orthop Relat Res; 2021 Apr; 479(4):736-744. PubMed ID: 33724977
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Mid-term results of the BIOLOX delta ceramic-on-ceramic total hip arthroplasty.
    Lee YK; Ha YC; Yoo JI; Jo WL; Kim KC; Koo KH
    Bone Joint J; 2017 Jun; 99-B(6):741-748. PubMed ID: 28566392
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Primary ceramic-on-ceramic total hip arthroplasty using a 32-mm ceramic head with a titanium-alloy sleeve.
    Lim SJ; Jang SP; Kim DW; Moon YW; Park YS
    Clin Orthop Relat Res; 2015 Dec; 473(12):3781-7. PubMed ID: 26024582
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Cementless metaphyseal fitting anatomic total hip arthroplasty with a ceramic-on-ceramic bearing in patients thirty years of age or younger.
    Kim YH; Park JW; Kim JS
    J Bone Joint Surg Am; 2012 Sep; 94(17):1570-5. PubMed ID: 22992847
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Could larger diameter of 4th generation ceramic bearing decrease the rate of dislocation after THA?
    Lee YK; Ha YC; Jo WL; Kim TY; Jung WH; Koo KH
    J Orthop Sci; 2016 May; 21(3):327-31. PubMed ID: 26876620
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Using Ceramic-on-Ceramic Bearings in Total Hip Arthroplasty Necessitating 44- or 46-mm Metal Shells.
    Park CH; Ha YC; Lee YK; Koo KH
    Orthopedics; 2018 May; 41(3):e354-e359. PubMed ID: 29570759
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.