These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

115 related articles for article (PubMed ID: 38220161)

  • 21. Influence of block-out on retentive force of thermoplastic resin clasps: an in vitro experimental and finite element analysis.
    Yamazaki T; Murakami N; Suzuki S; Handa K; Yatabe M; Takahashi H; Wakabayashi N
    J Prosthodont Res; 2019 Jul; 63(3):303-308. PubMed ID: 30704930
    [TBL] [Abstract][Full Text] [Related]  

  • 22. An in vitro comparison of retentive force and deformation of acetal resin and cobalt-chromium clasps.
    Arda T; Arikan A
    J Prosthet Dent; 2005 Sep; 94(3):267-74. PubMed ID: 16126079
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Effects of repetitive insertion/removal cycles and simulated occlusal loads on retention of denture retainers.
    Kato Y; Tasaka A; Kato M; Wadachi J; Takemoto S; Yamashita S
    Dent Mater J; 2021 Sep; 40(5):1277-1283. PubMed ID: 33883331
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Comparative study of circumferential clasp retention force for titanium and cobalt-chromium removable partial dentures.
    Rodrigues RC; Ribeiro RF; de Mattos Mda G; Bezzon OL
    J Prosthet Dent; 2002 Sep; 88(3):290-6. PubMed ID: 12426499
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Deformation and retentive forces variations of the additively manufactured cobalt-chromium and titanium alloys dental clasps.
    El-Tamimi KM; Bayoumi DA; Alshenaiber R; Aljulayfi I; Ahmed MMZ; El-Sayed ME
    Saudi Dent J; 2024 Jun; 36(6):947-953. PubMed ID: 38883903
    [TBL] [Abstract][Full Text] [Related]  

  • 26. New Clasp Assembly for Distal Extension Removable Partial Dentures: The Reverse RPA Clasp.
    Hakkoum MA
    J Prosthodont; 2016 Jul; 25(5):411-3. PubMed ID: 26102601
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Comparison of the retentive characteristics of cobalt-chromium and commercially pure titanium clasps using a novel method.
    Tse ET; Cheng LY; Luk HW; Chu FC; Chai J; Chow TW
    Int J Prosthodont; 2006; 19(4):371-2. PubMed ID: 16900820
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Different Undercut Depths Influence on Fatigue Behavior and Retentive Force of Removable Partial Denture Clasp Materials: A Systematic Review.
    Zheng J; Aarts JM; Ma S; Waddell JN; Choi JJE
    J Prosthodont; 2023 Feb; 32(2):108-115. PubMed ID: 35405767
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Retentive forces and fatigue resistance of thermoplastic resin clasps.
    Tannous F; Steiner M; Shahin R; Kern M
    Dent Mater; 2012 Mar; 28(3):273-8. PubMed ID: 22130464
    [TBL] [Abstract][Full Text] [Related]  

  • 30. The effect of thermo-mechanical fatigue on the retentive force and dimensional changes in polyetheretherketone clasps with different thickness and undercut.
    Güleryüz A; Korkmaz C; Şener A; Taş MO
    J Adv Prosthodont; 2021 Oct; 13(5):304-315. PubMed ID: 34777720
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Analytical model of I-bar clasps for removable partial dentures.
    Richert R; Alsheghri AA; Alageel O; Caron E; Song J; Ducret M; Tamimi F
    Dent Mater; 2021 Jun; 37(6):1066-1072. PubMed ID: 33867171
    [TBL] [Abstract][Full Text] [Related]  

  • 32. A new design for partial denture circumferential clasp arms.
    Brockhurst PJ
    Aust Dent J; 1996 Oct; 41(5):317-23. PubMed ID: 8961605
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Retentive Forces and Deformation of Fitting Surface in RPD Clasp Made of Polyether-Ether-Ketone (PEEK).
    Vaddamanu SK; Alhamoudi FH; Chaturvedi S; Alqahtani NM; Addas MK; Alfarsi MA; Vyas R; Kanji MA; Zarbah MA; Alqahtani WMS; Alqahtani SM; Abdelmonem AM; Elmahdi AE
    Polymers (Basel); 2023 Feb; 15(4):. PubMed ID: 36850239
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Dynamic retentive force of a mandibular unilateral removable partial denture framework with a back-action clasp.
    Park I; Eto M; Wakabayashi N; Hideshima M; Ohyama T
    J Med Dent Sci; 2001 Dec; 48(4):105-11. PubMed ID: 12160247
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Performance of Graphene-Based and Polyether-Ether-Ketone Polymers as Removable Partial Denture Esthetic Clasp Materials after Cyclic Fatigue.
    Hussein MO
    Polymers (Basel); 2022 Jul; 14(15):. PubMed ID: 35893952
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Titanium clasp fabricated by selective laser melting, CNC milling, and conventional casting: a comparative in vitro study.
    Tan FB; Song JL; Wang C; Fan YB; Dai HW
    J Prosthodont Res; 2019 Jan; 63(1):58-65. PubMed ID: 30309743
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Finite element analysis in defining the optimal shape and safety factor of retentive clasp arms of a removable partial denture.
    Sćepanović M; Tihacek-Sojić L; Tasić M; Mitrović R; Todorović A; Trifković B
    Vojnosanit Pregl; 2013 Nov; 70(11):999-1005. PubMed ID: 24397193
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Fatigue resistance and retentive force of cast clasps treated by shot peening.
    Tokue A; Hayakawa T; Ohkubo C
    J Prosthodont Res; 2013 Jul; 57(3):186-94. PubMed ID: 23809297
    [TBL] [Abstract][Full Text] [Related]  

  • 39. [Cyclic fatigue test of cobalt-chromium alloy cast clasps].
    Xu MR; Cheng H; Zheng M; Li XR; Wu WQ; Chen D
    Zhonghua Kou Qiang Yi Xue Za Zhi; 2010 Jan; 45(1):36-8. PubMed ID: 20368039
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Retention for a removable partial denture.
    Johnson DL
    J Prosthodont; 1992 Sep; 1(1):11-7. PubMed ID: 1308213
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 6.