151 related articles for article (PubMed ID: 38222270)
1. Impact of potassium test sample rejections on routine laboratory service, South Africa.
McAlpine S; Chale-Matsau B
Afr J Lab Med; 2023; 12(1):2239. PubMed ID: 38222270
[TBL] [Abstract][Full Text] [Related]
2. Chemistry and haematology sample rejection and clinical impact in a tertiary laboratory in Cape Town.
Jacobsz LA; Zemlin AE; Roos MJ; Erasmus RT
Clin Chem Lab Med; 2011 Oct; 49(12):2047-50. PubMed ID: 21995606
[TBL] [Abstract][Full Text] [Related]
3. Assessing CD4 rejections across a national laboratory service for 2018 in South Africa: highlighting the importance of adherence to national handbook guidelines.
Cassim N; Buthelezi EP; Coetzee LM; Glencross DK
J Public Health Afr; 2022 May; 13(1):1278. PubMed ID: 35720799
[TBL] [Abstract][Full Text] [Related]
4. Assessment of Pre-analytical Errors and Fostering Strategies to Enhance Accurate Results and Efficient Turnaround Times in the Cytology Laboratory of a Tertiary Care Hospital.
Kani V; K K; Sonti S
Cureus; 2024 Mar; 16(3):e56592. PubMed ID: 38646273
[TBL] [Abstract][Full Text] [Related]
5. Delays in HIV-1 infant polymerase chain reaction testing may leave children without confirmed diagnoses in the Western Cape province, South Africa.
Mahlakwane KL; Preiser W; Nkosi N; Naidoo N; van Zyl G
Afr J Lab Med; 2022; 11(1):1485. PubMed ID: 35811753
[TBL] [Abstract][Full Text] [Related]
6. Factors influencing the high rejection rates of HIV 1/2 serology samples at Charlotte Maxeke Johannesburg Academic Hospital and the cost implications.
Reddy B; Cassim N; Treurnicht F; Makatini Z
South Afr J HIV Med; 2022; 23(1):1326. PubMed ID: 35169497
[TBL] [Abstract][Full Text] [Related]
7. Causes and impact of specimen rejection in a clinical chemistry laboratory.
Cao L; Chen M; Phipps RA; Del Guidice RE; Handy BC; Wagar EA; Meng QH
Clin Chim Acta; 2016 Jul; 458():154-8. PubMed ID: 27166198
[TBL] [Abstract][Full Text] [Related]
8. Determining the rate and reasons for specimen rejection among specimens referred for HIV viral load determination through referral linkage to Debre Tabor Comprehensive Specialized Hospital, north-central, Ethiopia,2023: Retrospective study.
Berhan A; Almaw A; Damtie S; Solomon Y; Legese B; Getie B; Erkihun M
Heliyon; 2024 Jun; 10(11):e31736. PubMed ID: 38845923
[TBL] [Abstract][Full Text] [Related]
9. Analysis of laboratory sample rejections in the pre-analytical stage at an oncology center.
Bhat V; Tiwari M; Chavan P; Kelkar R
Clin Chim Acta; 2012 Aug; 413(15-16):1203-6. PubMed ID: 22507083
[TBL] [Abstract][Full Text] [Related]
10. Preanalytical Errors in Clinical Biochemistry Laboratory and Relationship With Hospital Departments and Staff: A Record-Based Study.
Dundar C; Bahadir O
J Patient Saf; 2023 Jun; 19(4):239-242. PubMed ID: 36849433
[TBL] [Abstract][Full Text] [Related]
11. Reducing sample rejection in Durban, South Africa.
Magwai T; Warasally Z; Naidoo N; Gounden V
Clin Chem Lab Med; 2021 Mar; 59(4):687-692. PubMed ID: 33079694
[TBL] [Abstract][Full Text] [Related]
12. Specimen rejection in laboratory medicine: Necessary for patient safety?
Dikmen ZG; Pinar A; Akbiyik F
Biochem Med (Zagreb); 2015; 25(3):377-85. PubMed ID: 26527231
[TBL] [Abstract][Full Text] [Related]
13. Analyzing clinical laboratory specimen rejection rates at a specialized hospital in Ethiopia: A 2-year document review.
Deress T; Abebaw Y; Esayas Y; Nebertu S; Kinidie M; Abebe G; Bayleyegn B
Am J Clin Pathol; 2024 Mar; ():. PubMed ID: 38459898
[TBL] [Abstract][Full Text] [Related]
14. Rates and Reasons of Laboratory Sample Rejection due to Pre-analytical Errors in Clinical Settings.
Jafari E; Malekpour Afshar R; Aminzade R
Arch Iran Med; 2022 Mar; 25(3):166-170. PubMed ID: 35429958
[TBL] [Abstract][Full Text] [Related]
15. [Evaluation of Pre-analytical Process with Quality Indicators and Six Sigma Methodology in the Parasitology Laboratory of a Tertiary Healthcare Center].
Zorbozan O; Zorbozan N; Turgay N
Mikrobiyol Bul; 2019 Jul; 53(3):319-329. PubMed ID: 31414633
[TBL] [Abstract][Full Text] [Related]
16. Classification of reasons for rejection of biological specimens based on pre-preanalytical processes to identify quality indicators at a university hospital clinical laboratory in Turkey.
Sinici Lay I; Pınar A; Akbıyık F
Clin Biochem; 2014 Aug; 47(12):1002-5. PubMed ID: 24794787
[TBL] [Abstract][Full Text] [Related]
17. The prevalence of pre-analytical errors in the laboratory of the Cantonal Hospital Zenica in Bosnia and Herzegovina.
Kadić D; Avdagić Ismić A; Hasić S
Med Glas (Zenica); 2019 Feb; 16(1):1-6. PubMed ID: 30680978
[TBL] [Abstract][Full Text] [Related]
18. Implications of differences between point-of-care blood gas analyser and laboratory analyser potassium results on hyperkalaemia diagnosis & treatment.
Pradhan J; Harding AM; Taylor SE; Lam Q
Intern Med J; 2023 Nov; 53(11):2035-2041. PubMed ID: 36645311
[TBL] [Abstract][Full Text] [Related]
19. Challenges in Preanalytical Phase of Laboratory Medicine: Rate of Blood Sample Nonconformity in a Tertiary Care Hospital.
Alavi N; Khan SH; Saadia A; Naeem T
EJIFCC; 2020 Mar; 31(1):21-27. PubMed ID: 32256286
[TBL] [Abstract][Full Text] [Related]
20. Dried blood spot specimen quality and validation of a new pre-analytical processing method for qualitative HIV-1 PCR, KwaZulu-Natal, South Africa.
Govender K; Parboosing R; Siyaca N; Moodley P
Afr J Lab Med; 2016; 5(1):349. PubMed ID: 28879108
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]