These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
118 related articles for article (PubMed ID: 38229451)
1. Socio-economic disparities in hospital care among Dutch patients with diabetes mellitus. de Vries SAG; Sas TCJ; Bak JCG; Mul D; Nieuwdorp M; Wouters MWJM; Verheugt CL Diabetes Obes Metab; 2024 Apr; 26(4):1386-1394. PubMed ID: 38229451 [TBL] [Abstract][Full Text] [Related]
2. Mediating Effects of Technology-Based Therapy on the Relationship Between Socioeconomic Status and Glycemic Management in Pediatric Type 1 Diabetes. Stanley JR; Clarke ABM; Shulman R; Mahmud FH Diabetes Technol Ther; 2023 Mar; 25(3):186-193. PubMed ID: 36409503 [No Abstract] [Full Text] [Related]
3. Glycemic Outcomes in Adults With T1D Are Impacted More by Continuous Glucose Monitoring Than by Insulin Delivery Method: 3 Years of Follow-Up From the COMISAIR Study. Šoupal J; Petruželková L; Grunberger G; Hásková A; Flekač M; Matoulek M; Mikeš O; Pelcl T; Škrha J; Horová E; Škrha J; Parkin CG; Svačina Š; Prázný M Diabetes Care; 2020 Jan; 43(1):37-43. PubMed ID: 31530663 [TBL] [Abstract][Full Text] [Related]
4. Comparison of flash glucose monitoring with real time continuous glucose monitoring in children and adolescents with type 1 diabetes treated with continuous subcutaneous insulin infusion. Massa GG; Gys I; Bevilacqua E; Wijnands A; Zeevaert R Diabetes Res Clin Pract; 2019 Jun; 152():111-118. PubMed ID: 31121275 [TBL] [Abstract][Full Text] [Related]
5. Continuous subcutaneous insulin infusion versus multiple daily injections in children and young people at diagnosis of type 1 diabetes: the SCIPI RCT. Blair J; McKay A; Ridyard C; Thornborough K; Bedson E; Peak M; Didi M; Annan F; Gregory JW; Hughes D; Gamble C Health Technol Assess; 2018 Aug; 22(42):1-112. PubMed ID: 30109847 [TBL] [Abstract][Full Text] [Related]
6. Cutaneous Reactions to Continuous Glucose Monitoring and Continuous Subcutaneous Insulin Infusion Devices in Type 1 Diabetes Mellitus. Rigo RS; Levin LE; Belsito DV; Garzon MC; Gandica R; Williams KM J Diabetes Sci Technol; 2021 Jul; 15(4):786-791. PubMed ID: 32389062 [TBL] [Abstract][Full Text] [Related]
7. Integrated sensor-augmented pump therapy systems [the MiniMed® Paradigm™ Veo system and the Vibe™ and G4® PLATINUM CGM (continuous glucose monitoring) system] for managing blood glucose levels in type 1 diabetes: a systematic review and economic evaluation. Riemsma R; Corro Ramos I; Birnie R; Büyükkaramikli N; Armstrong N; Ryder S; Duffy S; Worthy G; Al M; Severens J; Kleijnen J Health Technol Assess; 2016 Feb; 20(17):v-xxxi, 1-251. PubMed ID: 26933827 [TBL] [Abstract][Full Text] [Related]
8. Comparing the effectiveness of continuous subcutaneous insulin infusion with multiple daily insulin injection for patients with type 1 diabetes mellitus evaluated by retrospective continuous glucose monitoring: A real-world data analysis. Keyu G; Jiaqi L; Liyin Z; Jianan Y; Li F; Zhiyi D; Qin Z; Xia L; Lin Y; Zhiguang Z Front Public Health; 2022; 10():990281. PubMed ID: 36091534 [TBL] [Abstract][Full Text] [Related]
9. Epidemiological characterization of diabetic patients on therapy with continuous subcutaneous insulin infusion and continuous glucose monitoring in real time. Aristizábal N; Ramírez A; Hincapié-García J; Laiton E; Aristizábal C; Cuesta D; Monsalve C; Hincapié G; Zapata E; Abad V; Delgado MR; Torres JL; Palacio A; Botero J; Endocrinol Nutr; 2015 Nov; 62(9):451-7. PubMed ID: 26521154 [TBL] [Abstract][Full Text] [Related]
10. Methods for insulin delivery and glucose monitoring in diabetes: summary of a comparative effectiveness review. Golden SH; Sapir T J Manag Care Pharm; 2012 Aug; 18(6 Suppl):S1-17. PubMed ID: 22984955 [TBL] [Abstract][Full Text] [Related]
11. Diabetes technology and treatments in the paediatric age group. Shalitin S; Peter Chase H Int J Clin Pract Suppl; 2011 Feb; (170):76-82. PubMed ID: 21323816 [TBL] [Abstract][Full Text] [Related]
12. Comparative effectiveness and safety of methods of insulin delivery and glucose monitoring for diabetes mellitus: a systematic review and meta-analysis. Yeh HC; Brown TT; Maruthur N; Ranasinghe P; Berger Z; Suh YD; Wilson LM; Haberl EB; Brick J; Bass EB; Golden SH Ann Intern Med; 2012 Sep; 157(5):336-47. PubMed ID: 22777524 [TBL] [Abstract][Full Text] [Related]
13. Treatment satisfaction and quality of life for an integrated continuous glucose monitoring/insulin pump system compared to self-monitoring plus an insulin pump. Rubin RR; Peyrot M J Diabetes Sci Technol; 2009 Nov; 3(6):1402-10. PubMed ID: 20144395 [TBL] [Abstract][Full Text] [Related]
14. Continuous Glucose Monitoring Use in Type 1 Diabetes: Longitudinal Analysis Demonstrates Meaningful Improvements in HbA1c and Reductions in Health Care Utilization. Parkin CG; Graham C; Smolskis J J Diabetes Sci Technol; 2017 May; 11(3):522-528. PubMed ID: 28745091 [TBL] [Abstract][Full Text] [Related]
15. Optimizing type 1 diabetes after multiple daily injections and capillary blood monitoring: Pump or sensor first? A meta-analysis using pooled differences in outcome measures. Thomas MG; Avari P; Godsland IF; Lett AM; Reddy M; Oliver N Diabetes Obes Metab; 2021 Nov; 23(11):2521-2528. PubMed ID: 34286892 [TBL] [Abstract][Full Text] [Related]
16. Continuous Glucose Monitoring in Adults with Type 1 Diabetes: Real-World Data from the German/Austrian Prospective Diabetes Follow-Up Registry. Sandig D; Grimsmann J; Reinauer C; Melmer A; Zimny S; Müller-Korbsch M; Forestier N; Zeyfang A; Bramlage P; Danne T; Meissner T; Holl RW Diabetes Technol Ther; 2020 Aug; 22(8):602-612. PubMed ID: 32522039 [No Abstract] [Full Text] [Related]
17. Effect of initiating use of an insulin pump in adults with type 1 diabetes using multiple daily insulin injections and continuous glucose monitoring (DIAMOND): a multicentre, randomised controlled trial. Beck RW; Riddlesworth TD; Ruedy KJ; Kollman C; Ahmann AJ; Bergenstal RM; Bhargava A; Bode BW; Haller S; Kruger DF; McGill JB; Polonsky W; Price D; Toschi E; Lancet Diabetes Endocrinol; 2017 Sep; 5(9):700-708. PubMed ID: 28711468 [TBL] [Abstract][Full Text] [Related]
18. Continuous Subcutaneous Insulin Infusion in Adult Type 1 Diabetes Mellitus Patients: Results from a Public Health System. Moreno-Fernandez J; Gomez FJ; Pinés P; González J; López J; López LM; Blanco B; Roa C; Herranz S; Muñoz-Rodríguez JR Diabetes Technol Ther; 2019 Aug; 21(8):440-447. PubMed ID: 31199682 [No Abstract] [Full Text] [Related]
19. Skin Problems Associated with Insulin Pumps and Sensors in Adults with Type 1 Diabetes: A Cross-Sectional Study. Berg AK; Nørgaard K; Thyssen JP; Zachariae C; Hommel E; Rytter K; Svensson J Diabetes Technol Ther; 2018 Jul; 20(7):475-482. PubMed ID: 29893593 [TBL] [Abstract][Full Text] [Related]
20. Impact of technology on glycaemic control in type 2 diabetes: A meta-analysis of randomized trials on continuous glucose monitoring and continuous subcutaneous insulin infusion. Dicembrini I; Mannucci E; Monami M; Pala L Diabetes Obes Metab; 2019 Dec; 21(12):2619-2625. PubMed ID: 31368658 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]