130 related articles for article (PubMed ID: 3823415)
1. Selecting the best screen-film combination.
Stears JG; Gray JE; Frank ED
Radiol Technol; 1987; 58(3):239-42. PubMed ID: 3823415
[No Abstract] [Full Text] [Related]
2. [Measurement of objective parameters of image quality of film-screen combinations].
Angerstein W; Wolf M
Radiol Diagn (Berl); 1986; 27(1):69-76. PubMed ID: 3961142
[No Abstract] [Full Text] [Related]
3. [X-ray intensifying screens: their effect on the quality of the image and the degree of irradiation].
Tombak MI; Vlasov PV; Gurvich AM; Gurevich IA; Katomina RV
Vestn Rentgenol Radiol; 1984; (5):80-4. PubMed ID: 6528468
[No Abstract] [Full Text] [Related]
4. [Characteristics of screen-film systems for mammography in relation to a diverse modality of treatment].
Rosselli Del Turco M; Milano F; Giani M; Bravetti P
Radiol Med; 1988 Apr; 75(4):390-4. PubMed ID: 3375482
[No Abstract] [Full Text] [Related]
5. Evaluation of image blur (unsharpness) in medical imaging.
Haus AG
Med Radiogr Photogr; 1985 Jun; 61(1-2):42-53. PubMed ID: 3900624
[No Abstract] [Full Text] [Related]
6. [Image quality parameters of film-screen systems].
Hoeschen D
Rontgenblatter; 1987 Jun; 40(6):193-9. PubMed ID: 3616429
[TBL] [Abstract][Full Text] [Related]
7. [Sharpness of detail and density in film-screen systems].
Maurer HJ; Goos F
Rontgenblatter; 1986 Sep; 39(9):260-3. PubMed ID: 3775203
[TBL] [Abstract][Full Text] [Related]
8. [New imaging methods in thoracic diagnosis. A study to evaluate digital storage screen radiography, the slit technique ("AMBER"), asymmetric ("InSight") and conventional film-screen techniques].
Lehmann KJ; Busch HP; Drescher P; Loose R; Georgi M
Aktuelle Radiol; 1993 Jan; 3(1):14-9. PubMed ID: 8448224
[TBL] [Abstract][Full Text] [Related]
9. [Measurement of the modulation transfer function of film-screen combinations with a lead scanning pattern].
Hoeschen D; Mirandé W
Rofo; 1984 May; 140(5):600-4. PubMed ID: 6429767
[TBL] [Abstract][Full Text] [Related]
10. [Image enhancer-television equipment--image quality and dose].
Larwin K
Strahlenschutz Forsch Prax; 1986; 27():43-7. PubMed ID: 3705125
[No Abstract] [Full Text] [Related]
11. Reciprocity law failure for a film-screen combination: very long exposure times.
Hale J; Thomas JW
Health Phys; 1983 Sep; 45(3):780-2. PubMed ID: 6885487
[No Abstract] [Full Text] [Related]
12. [Modification of the quality of the roentgen image by screen and film--experimental studies].
Maurer HJ; Goos F
Rontgenblatter; 1985 Feb; 38(2):54-7. PubMed ID: 3983537
[No Abstract] [Full Text] [Related]
13. [Will the new highly intensifying film-screen combination of the Kodak T-MAT G/Lanex Regular meet the qualitative requirements of the lateral teleroentgenogram and orthopantomogram?].
Schulz D; Bührmann K; Plein-Jakobs E; Jakobs W
Fortschr Kieferorthop; 1988 Jun; 49(3):305-11. PubMed ID: 3165364
[No Abstract] [Full Text] [Related]
14. [Intensifying screens: speed, definition, afterglow and abrasion resistance (author's transl)].
de Moras Y; Lucas P; Bergeret B; Picard F; Fauduet A; Pelgas MF; Serrurot M
J Radiol; 1982 Mar; 63(3):189-96. PubMed ID: 7108845
[TBL] [Abstract][Full Text] [Related]
15. [Analysis of frequency-contrast characteristics of digital X-ray image detectors].
Zelikman MI; Kabanov SP; Kokuev AN; Kruchinin SA; Lobov DP
Med Tekh; 2006; (5):23-7. PubMed ID: 17133940
[TBL] [Abstract][Full Text] [Related]
16. [Digital roentgenographic systems based on photostimulated screens and their comparison with roentgenographic screen-film sets].
Gorelik FG; Stankevich NE
Med Tekh; 2006; (5):10-3. PubMed ID: 17133936
[TBL] [Abstract][Full Text] [Related]
17. Selection of optimal screen-film combination for use in the neonatal intensive care unit.
Smith WL; Franken EA; Frangi SM; Windsor C
AJR Am J Roentgenol; 1982 Dec; 139(6):1051-3. PubMed ID: 6756100
[TBL] [Abstract][Full Text] [Related]
18. [Image contrast in various cassette-screen-film combinations].
Barth HH; Grasser H
Dtsch Zahnarztl Z; 1985 Dec; 40(12):1230-4. PubMed ID: 3869536
[No Abstract] [Full Text] [Related]
19. [Basic parameters and testing methods for medical roentgen screens].
Gurvich AM; Il'ina MA; Katomina RV
Med Tekh; 1987; (6):38-44. PubMed ID: 3326993
[TBL] [Abstract][Full Text] [Related]
20. National survey with regard to preferred image characteristics of various types of intensifying screens.
van der Zwaag H
Diagn Imaging Clin Med; 1984; 53(4):215-20. PubMed ID: 6565544
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]