120 related articles for article (PubMed ID: 38237522)
21. Improving image quality with super-resolution deep-learning-based reconstruction in coronary CT angiography.
Nagayama Y; Emoto T; Kato Y; Kidoh M; Oda S; Sakabe D; Funama Y; Nakaura T; Hayashi H; Takada S; Uchimura R; Hatemura M; Tsujita K; Hirai T
Eur Radiol; 2023 Dec; 33(12):8488-8500. PubMed ID: 37432405
[TBL] [Abstract][Full Text] [Related]
22. Assessment of a model-based, iterative reconstruction algorithm (MBIR) regarding image quality and dose reduction in liver computed tomography.
Chang W; Lee JM; Lee K; Yoon JH; Yu MH; Han JK; Choi BI
Invest Radiol; 2013 Aug; 48(8):598-606. PubMed ID: 23511193
[TBL] [Abstract][Full Text] [Related]
23. Comparison of iterative model, hybrid iterative, and filtered back projection reconstruction techniques in low-dose brain CT: impact of thin-slice imaging.
Nakaura T; Iyama Y; Kidoh M; Yokoyama K; Oda S; Tokuyasu S; Harada K; Yamashita Y
Neuroradiology; 2016 Mar; 58(3):245-51. PubMed ID: 26715558
[TBL] [Abstract][Full Text] [Related]
24. Reduced-dose abdominopelvic CT using hybrid iterative reconstruction in suspected left-sided colonic diverticulitis.
Laqmani A; Veldhoen S; Dulz S; Derlin T; Behzadi C; Schmidt-Holtz J; Wassenberg F; Sehner S; Nagel HD; Adam G; Regier M
Eur Radiol; 2016 Jan; 26(1):216-24. PubMed ID: 26070499
[TBL] [Abstract][Full Text] [Related]
25. Deep learning-based iodine contrast-augmenting algorithm for low-contrast-dose liver CT to assess hypovascular hepatic metastasis.
Lee T; Yoon JH; Park JY; Lee J; Choi JW; Ahn C; Lee JM
Abdom Radiol (NY); 2023 Nov; 48(11):3430-3440. PubMed ID: 37704805
[TBL] [Abstract][Full Text] [Related]
26. Value of deep learning reconstruction at ultra-low-dose CT for evaluation of urolithiasis.
Zhang G; Zhang X; Xu L; Bai X; Jin R; Xu M; Yan J; Jin Z; Sun H
Eur Radiol; 2022 Sep; 32(9):5954-5963. PubMed ID: 35357541
[TBL] [Abstract][Full Text] [Related]
27. Hybrid iterative reconstruction technique for liver CT scans for image noise reduction and image quality improvement: evaluation of the optimal iterative reconstruction strengths.
Song JS; Lee JM; Sohn JY; Yoon JH; Han JK; Choi BI
Radiol Med; 2015 Mar; 120(3):259-67. PubMed ID: 25168773
[TBL] [Abstract][Full Text] [Related]
28. Cardiac CT for planning redo cardiac surgery: effect of knowledge-based iterative model reconstruction on image quality.
Oda S; Weissman G; Vembar M; Weigold WG
Eur Radiol; 2015 Jan; 25(1):58-64. PubMed ID: 25182629
[TBL] [Abstract][Full Text] [Related]
29. Diagnostic performance of reduced-dose CT with a hybrid iterative reconstruction algorithm for the detection of hypervascular liver lesions: a phantom study.
Nakamoto A; Tanaka Y; Juri H; Nakai G; Yoshikawa S; Narumi Y
Eur Radiol; 2017 Jul; 27(7):2995-3003. PubMed ID: 27957640
[TBL] [Abstract][Full Text] [Related]
30. Abdominopelvic CT Image Quality: Evaluation of Thin (0.5-mm) Slices Using Deep Learning Reconstruction.
Oostveen LJ; Smit EJ; Dekker HM; Buckens CF; Pegge SAH; de Lange F; Sechopoulos I; Prokop M
AJR Am J Roentgenol; 2023 Mar; 220(3):381-388. PubMed ID: 36259592
[No Abstract] [Full Text] [Related]
31. Assessment of low-dose paranasal sinus CT imaging using a new deep learning image reconstruction technique in children compared to adaptive statistical iterative reconstruction V (ASiR-V).
Li Y; Liu X; Zhuang XH; Wang MJ; Song XF
BMC Med Imaging; 2022 Jun; 22(1):106. PubMed ID: 35658908
[TBL] [Abstract][Full Text] [Related]
32. Deep learning image reconstruction for improvement of image quality of abdominal computed tomography: comparison with hybrid iterative reconstruction.
Ichikawa Y; Kanii Y; Yamazaki A; Nagasawa N; Nagata M; Ishida M; Kitagawa K; Sakuma H
Jpn J Radiol; 2021 Jun; 39(6):598-604. PubMed ID: 33449305
[TBL] [Abstract][Full Text] [Related]
33. Model-based iterative reconstruction and adaptive statistical iterative reconstruction techniques in abdominal CT: comparison of image quality in the detection of colorectal liver metastases.
Volders D; Bols A; Haspeslagh M; Coenegrachts K
Radiology; 2013 Nov; 269(2):469-74. PubMed ID: 23847252
[TBL] [Abstract][Full Text] [Related]
34. Lung-Optimized Deep-Learning-Based Reconstruction for Ultralow-Dose CT.
Goto M; Nagayama Y; Sakabe D; Emoto T; Kidoh M; Oda S; Nakaura T; Taguchi N; Funama Y; Takada S; Uchimura R; Hayashi H; Hatemura M; Kawanaka K; Hirai T
Acad Radiol; 2023 Mar; 30(3):431-440. PubMed ID: 35738988
[TBL] [Abstract][Full Text] [Related]
35. Deep learning trained algorithm maintains the quality of half-dose contrast-enhanced liver computed tomography images: Comparison with hybrid iterative reconstruction: Study for the application of deep learning noise reduction technology in low dose.
Zeng L; Xu X; Zeng W; Peng W; Zhang J; Sixian H; Liu K; Xia C; Li Z
Eur J Radiol; 2021 Feb; 135():109487. PubMed ID: 33418383
[TBL] [Abstract][Full Text] [Related]
36. Potential value of the PixelShine deep learning algorithm for increasing quality of 70 kVp+ASiR-V reconstruction pelvic arterial phase CT images.
Tian SF; Liu AL; Liu JH; Liu YJ; Pan JD
Jpn J Radiol; 2019 Feb; 37(2):186-190. PubMed ID: 30523499
[TBL] [Abstract][Full Text] [Related]
37. Value of deep learning reconstruction of chest low-dose CT for image quality improvement and lung parenchyma assessment on lung window.
Wang J; Sui X; Zhao R; Du H; Wang J; Wang Y; Qin R; Lu X; Ma Z; Xu Y; Jin Z; Song L; Song W
Eur Radiol; 2024 Feb; 34(2):1053-1064. PubMed ID: 37581663
[TBL] [Abstract][Full Text] [Related]
38. Deep learning reconstruction improves image quality of abdominal ultra-high-resolution CT.
Akagi M; Nakamura Y; Higaki T; Narita K; Honda Y; Zhou J; Yu Z; Akino N; Awai K
Eur Radiol; 2019 Nov; 29(11):6163-6171. PubMed ID: 30976831
[TBL] [Abstract][Full Text] [Related]
39. Deep learning image reconstruction for improving image quality of contrast-enhanced dual-energy CT in abdomen.
Sato M; Ichikawa Y; Domae K; Yoshikawa K; Kanii Y; Yamazaki A; Nagasawa N; Nagata M; Ishida M; Sakuma H
Eur Radiol; 2022 Aug; 32(8):5499-5507. PubMed ID: 35238970
[TBL] [Abstract][Full Text] [Related]
40. Thin-slice brain CT with iterative model reconstruction algorithm for small lacunar lesions detection: Image quality and diagnostic accuracy evaluation.
Liu X; Chen L; Qi W; Jiang Y; Liu Y; Zhang M; Hong N
Medicine (Baltimore); 2017 Dec; 96(51):e9412. PubMed ID: 29390563
[TBL] [Abstract][Full Text] [Related]
[Previous] [Next] [New Search]