BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

128 related articles for article (PubMed ID: 38241727)

  • 1. Pencil beam kernel-based dose calculations on CT data for a mixed neutron-gamma fission field applying tissue correction factors.
    Sommer LB; Kampfer S; Chemnitz T; Breitkreutz H; Combs SE; Wilkens JJ
    Phys Med Biol; 2024 Feb; 69(4):. PubMed ID: 38241727
    [No Abstract]   [Full Text] [Related]  

  • 2. Monte Carlo evaluation of a photon pencil kernel algorithm applied to fast neutron therapy treatment planning.
    Söderberg J; Alm Carlsson G; Ahnesjö A
    Phys Med Biol; 2003 Oct; 48(20):3327-44. PubMed ID: 14620061
    [TBL] [Abstract][Full Text] [Related]  

  • 3. A dose voxel kernel method for rapid reconstruction of out-of-field neutron dose of patients in pencil beam scanning (PBS) proton therapy.
    Yeom YS; Griffin K; Mille M; Jung JW; Lee C; Lee C
    Phys Med Biol; 2020 Aug; 65(17):175015. PubMed ID: 32726766
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Dose-response relationship of dicentric chromosomes in human lymphocytes obtained for the fission neutron therapy facility MEDAPP at the research reactor FRM II.
    Schmid E; Wagner FM; Romm H; Walsh L; Roos H
    Radiat Environ Biophys; 2009 Feb; 48(1):67-75. PubMed ID: 18979115
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Empirical description and Monte Carlo simulation of fast neutron pencil beams as basis of a treatment planning system.
    Bourhis-Martin E; Meissner P; Rassow J; Baumhoer W; Schmidt R; Sauerwein W
    Med Phys; 2002 Aug; 29(8):1670-7. PubMed ID: 12201412
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Quantitative assessment of the accuracy of dose calculation using pencil beam and Monte Carlo algorithms and requirements for clinical quality assurance.
    Ali I; Ahmad S
    Med Dosim; 2013; 38(3):255-61. PubMed ID: 23558145
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Validation of a pencil beam model-based treatment planning system for fast neutron therapy.
    Bourhis-Martin E; Meissner P; Rassow J; Baumhoer W; Schmidt R; Sauerwein W
    Med Phys; 2003 Jan; 30(1):21-6. PubMed ID: 12557974
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Are neutrons responsible for the dose discrepancies between Monte Carlo calculations and measurements in the build-up region for a high-energy photon beam?
    Ding GX; Duzenli C; Kalach NI
    Phys Med Biol; 2002 Sep; 47(17):3251-61. PubMed ID: 12361221
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Clinical implementation of full Monte Carlo dose calculation in proton beam therapy.
    Paganetti H; Jiang H; Parodi K; Slopsema R; Engelsman M
    Phys Med Biol; 2008 Sep; 53(17):4825-53. PubMed ID: 18701772
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Monte Carlo-based treatment planning for boron neutron capture therapy using custom designed models automatically generated from CT data.
    Zamenhof R; Redmond E; Solares G; Katz D; Riley K; Kiger S; Harling O
    Int J Radiat Oncol Biol Phys; 1996 May; 35(2):383-97. PubMed ID: 8635948
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Advanced kernel methods vs. Monte Carlo-based dose calculation for high energy photon beams.
    Fotina I; Winkler P; Künzler T; Reiterer J; Simmat I; Georg D
    Radiother Oncol; 2009 Dec; 93(3):645-53. PubMed ID: 19926153
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Validation of dose planning calculations for boron neutron capture therapy using cylindrical and anthropomorphic phantoms.
    Koivunoro H; Seppälä T; Uusi-Simola J; Merimaa K; Kotiluoto P; Serén T; Kortesniemi M; Auterinen I; Savolainen S
    Phys Med Biol; 2010 Jun; 55(12):3515-33. PubMed ID: 20508317
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Very high-energy electron dose calculation using the Fermi-Eyges theory of multiple scattering and a simplified pencil beam model.
    Ronga MG; Deut U; Bonfrate A; De Marzi L
    Med Phys; 2023 Dec; 50(12):8009-8022. PubMed ID: 37730956
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Development of a dual phantom technique for measuring the fast neutron component of dose in boron neutron capture therapy.
    Sakurai Y; Tanaka H; Kondo N; Kinashi Y; Suzuki M; Masunaga S; Ono K; Maruhashi A
    Med Phys; 2015 Nov; 42(11):6651-7. PubMed ID: 26520755
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Effects of tissue heterogeneity and comparisons of collapsed cone and Monte Carlo fast neutron patient dosimetry using the University of Washington clinical neutron therapy system (CNTS).
    Moffitt GB; Sandison GA; Argento DC; Emery R; Wootton LS; Parvathaneni U; Liao JJ; Laramore GE; Stewart RD
    Phys Med Biol; 2023 Dec; 68(24):. PubMed ID: 37983905
    [TBL] [Abstract][Full Text] [Related]  

  • 16. SU-E-T-541: Dose Calculation Algorithm for External Neutron Radiotherapy Based on Pencil Beam Method.
    Moiseev A; Klimanov V
    Med Phys; 2012 Jun; 39(6Part18):3830. PubMed ID: 28518510
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Two-dimensional pencil beam scaling: an improved proton dose algorithm for heterogeneous media.
    Szymanowski H; Oelfke U
    Phys Med Biol; 2002 Sep; 47(18):3313-30. PubMed ID: 12375823
    [TBL] [Abstract][Full Text] [Related]  

  • 18. The Munich Fission Neutron Therapy Facility MEDAPP at the research reactor FRM II.
    Wagner FM; Kneschaurek P; Kastenmüller A; Loeper-Kabasakal B; Kampfer S; Breitkreutz H; Waschkowski W; Molls M; Petry W
    Strahlenther Onkol; 2008 Dec; 184(12):643-6. PubMed ID: 19107344
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Monte Carlo evaluation of tissue inhomogeneity effects in the treatment of the head and neck.
    Wang L; Yorke E; Chui CS
    Int J Radiat Oncol Biol Phys; 2001 Aug; 50(5):1339-49. PubMed ID: 11483347
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Use of the CT images for BNCT calculation: development of BNCT treatment planning system and its applications to dose calculation for voxel phantoms.
    Park SH; Han CY; Kim SY; Kim JK
    Radiat Prot Dosimetry; 2004; 110(1-4):661-7. PubMed ID: 15353727
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.