BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

122 related articles for article (PubMed ID: 38243604)

  • 1. Evaluating AAPM-TG-218 recommendations: Gamma index tolerance and action limits in IMRT and VMAT quality assurance using SunCHECK.
    Deng J; Liu S; Huang Y; Li X; Wu X
    J Appl Clin Med Phys; 2024 Jan; ():e14277. PubMed ID: 38243604
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Implementation of TG-218 for patient-specific quality assurance tolerance and action limits determination: Gamma passing rate evaluation using 3DVH software.
    Stasinou D; Patatoukas G; Kollaros N; Diamantopoulos S; Kypraiou E; Kougioumtzopoulou A; Kouloulias V; Efstathopoulos E; Platoni K
    Med Phys; 2022 Jul; 49(7):4322-4334. PubMed ID: 35560362
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Volumetric-modulated arc therapy for the treatment of a large planning target volume in thoracic esophageal cancer.
    Abbas AS; Moseley D; Kassam Z; Kim SM; Cho C
    J Appl Clin Med Phys; 2013 May; 14(3):4269. PubMed ID: 23652258
    [TBL] [Abstract][Full Text] [Related]  

  • 4. [Preliminary study on monitoring patient-specific volumetric modulated arc therapy quality assurance process with statistical process control methodology on the basis of TG-218 report].
    Xiao Q; Li G; Li Z; Zhang X; Dai G; Bai S
    Sheng Wu Yi Xue Gong Cheng Xue Za Zhi; 2020 Oct; 37(5):842-847. PubMed ID: 33140608
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Evaluation of fixed-jaw IMRT and tangential partial-VMAT radiotherapy plans for synchronous bilateral breast cancer irradiation based on a dosimetric study.
    Huang JH; Wu XX; Lin X; Shi JT; Ma YJ; Duan S; Huang XB
    J Appl Clin Med Phys; 2019 Sep; 20(9):31-41. PubMed ID: 31483573
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Individual volume-based 3D gamma indices for pretreatment VMAT QA.
    Yi J; Han C; Zheng X; Zhou Y; Deng Z; Xie C; Jin X; Jin F
    J Appl Clin Med Phys; 2017 May; 18(3):28-36. PubMed ID: 28318101
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Validation and IMRT/VMAT delivery quality of a preconfigured fast-rotating O-ring linac system.
    De Roover R; Crijns W; Poels K; Michiels S; Nulens A; Vanstraelen B; Petillion S; De Brabandere M; Haustermans K; Depuydt T
    Med Phys; 2019 Jan; 46(1):328-339. PubMed ID: 30417523
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Efficient dose-volume histogram-based pretreatment patient-specific quality assurance methodology with combined deep learning and machine learning models for volumetric modulated arc radiotherapy.
    Gong C; Zhu K; Lin C; Han C; Lu Z; Chen Y; Yu C; Hou L; Zhou Y; Yi J; Ai Y; Xiang X; Xie C; Jin X
    Med Phys; 2022 Dec; 49(12):7779-7790. PubMed ID: 36190117
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Evaluation of an automated template-based treatment planning system for radiotherapy of anal, rectal and prostate cancer.
    Calmels L; Sibolt P; Åström LM; Serup-Hansen E; Lindberg H; Fromm AL; Persson G; Sjöström D; Geertsen P; Behrens CP
    Tech Innov Patient Support Radiat Oncol; 2022 Jun; 22():30-36. PubMed ID: 35464888
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Is volumetric modulated arc therapy with constant dose rate a valid option in radiation therapy for head and neck cancer patients?
    Didona A; Lancellotta V; Zucchetti C; Panizza BM; Frattegiani A; Iacco M; Di Pilato AC; Saldi S; Aristei C
    Rep Pract Oncol Radiother; 2018; 23(3):175-182. PubMed ID: 29765265
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Comprehensive validation of halcyon 2.0 plans and the implementation of patient specific QA with multiple detector platforms.
    Laugeman E; Heermann A; Hilliard J; Watts M; Roberson M; Morris R; Goddu S; Sethi A; Zoberi I; Kim H; Mutic S; Hugo G; Cai B
    J Appl Clin Med Phys; 2020 Jul; 21(7):39-48. PubMed ID: 32368862
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Comparative analysis of SmartArc-based dual arc volumetric-modulated arc radiotherapy (VMAT) versus intensity-modulated radiotherapy (IMRT) for nasopharyngeal carcinoma.
    Lee TF; Chao PJ; Ting HM; Lo SH; Wang YW; Tuan CC; Fang FM; Su TJ
    J Appl Clin Med Phys; 2011 Nov; 12(4):3587. PubMed ID: 22089015
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Local confidence limits for IMRT and VMAT techniques: a study based on TG119 test suite.
    Thomas M; Chandroth M
    Australas Phys Eng Sci Med; 2014 Mar; 37(1):59-74. PubMed ID: 24414337
    [TBL] [Abstract][Full Text] [Related]  

  • 14. IMRT QA and gamma comparisons: The impact of detector geometry, spatial sampling, and delivery technique on gamma comparison sensitivity.
    Steers JM; Fraass BA
    Med Phys; 2021 Sep; 48(9):5367-5381. PubMed ID: 34036596
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Dosimetric Evaluation of Volumetric Modulated Arc Therapy (VMAT) and Intensity Modulated Radiotherapy (IMRT) Using AAPM TG 119 Protocol.
    A N; S A P
    J Biomed Phys Eng; 2019 Aug; 9(4):395-408. PubMed ID: 31531292
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Analyzation of the local confidence limits for IMRT and VMAT based on AAPM TG119 report.
    Zhang J; Jiang D; Liu H; Shen J; Wang D; Chen C; Xie C; Cao Z
    Med Dosim; 2020 Spring; 45(1):66-72. PubMed ID: 31296358
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Study on the transferability of the knowledge-based VMAT model to predict IMRT plans in prostate cancer radiotherapy.
    Bi S; Sun X; Sohaimi WFBW; Yusoff ALB
    Eur J Med Res; 2023 Aug; 28(1):309. PubMed ID: 37653551
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Advancing Precision in Post-mastectomy Chest Wall Radiotherapy: A Comparative Dosimetric Analysis of Volumetric-Modulated Arc Therapy (VMAT) and Intensity-Modulated Radiotherapy (IMRT) Based on Institutional Experience.
    Mishra SS; Nanda S; Ahirwar MK; Simran ; Rath SM
    Cureus; 2023 May; 15(5):e38464. PubMed ID: 37276065
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Volumetric arc therapy: A viable option for right-sided breast with comprehensive regional nodal irradiation in conjunction with deep inspiration breath hold.
    Holt E; Mantel A; Cokelek M; Tacey M; Jassal S; Law M; Zantuck N; Yong C; Cheng M; Viotto A; Foroudi F; Chao M
    J Med Imaging Radiat Sci; 2021 Jun; 52(2):223-237. PubMed ID: 33771509
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Dosimetric comparison of TomoDirect, helical tomotherapy, VMAT, and ff-IMRT for upper thoracic esophageal carcinoma.
    Zhang Y; Wang H; Huang X; Zhang Q; Ren R; Sun R; Zheng Z; Dong S; Zheng A
    Med Dosim; 2019 Summer; 44(2):167-172. PubMed ID: 29950277
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.