BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

143 related articles for article (PubMed ID: 38245617)

  • 1. The application of inverted lateral clavicle locking compression plate for medial clavicle fractures: biomechanical study and clinical implementation.
    Kritsaneephaiboon A; Jitprapaikulsarn S; Chantarapanich N; Klabklay P; Gromprasit A; Patamamongkonchai C; Dissaneewate P
    Eur J Orthop Surg Traumatol; 2024 Apr; 34(3):1465-1478. PubMed ID: 38245617
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Numerical simulation and biomechanical analysis of locking screw caps on clavicle locking plates.
    Kim DG; Min Kim S; Kim Y
    Medicine (Baltimore); 2022 Jul; 101(30):e29319. PubMed ID: 35905263
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Finite element analysis comparison between superior clavicle locking plate with and without screw holes above fracture zone in midshaft clavicular fracture.
    Pengrung N; Lakdee N; Puncreobutr C; Lohwongwatana B; Sa-Ngasoongsong P
    BMC Musculoskelet Disord; 2019 Oct; 20(1):465. PubMed ID: 31640668
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Comparative study of mechanical performance of various fixation constructs in multifragmentary distal humeral shaft fracture: a finite element analysis.
    Jitprapaikulsarn S; Chantarapanich N; Apivatthakakul T; Gromprasit A; Lertvilai P; Sukha K; Wanchat S; Mahaisavariya C
    Eur J Orthop Surg Traumatol; 2024 Apr; 34(3):1287-1296. PubMed ID: 38071686
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Finite element analysis of dual small plate fixation and single plate fixation for treatment of midshaft clavicle fractures.
    Zhang F; Chen F; Qi Y; Qian Z; Ni S; Zhong Z; Zhang X; Li D; Yu B
    J Orthop Surg Res; 2020 Apr; 15(1):148. PubMed ID: 32295608
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Two reconstruction plates provide superior stability of displaced midshaft clavicle fractures in comparison to single plating - A biomechanical study.
    Yanev P; Zderic I; Pukalski Y; Enchev D; Rashkov M; Varga P; Gehweiler D; Richards G; Gueorguiev B; Baltov A
    Clin Biomech (Bristol, Avon); 2020 Dec; 80():105199. PubMed ID: 33129563
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Biomechanical comparison of the Locking Compression superior anterior clavicle plate with seven and ten hole reconstruction plates in midshaft clavicle fracture stabilisation.
    Eden L; Doht S; Frey SP; Ziegler D; Stoyhe J; Fehske K; Blunk T; Meffert RH
    Int Orthop; 2012 Dec; 36(12):2537-43. PubMed ID: 23073924
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Modified pin and plate fixation for low intercondylar fractures of the humerus: biomechanical study corroborated with a case series.
    Jitprapaikulsarn S; Chantarapanich N; Gromprasit A; Mahaisavariya C; Patamamongkonchai C
    Musculoskelet Surg; 2023 Jun; 107(2):207-221. PubMed ID: 35362865
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Biomechanical analysis of plating techniques for unstable lateral clavicle fractures with coracoclavicular ligament disruption (Neer type IIB).
    Jo OI; Almond M; Rupansinghe HS; Ackland DC; Ernstbrunner L; Ek ET
    J Shoulder Elbow Surg; 2023 Apr; 32(4):695-702. PubMed ID: 36535559
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Dual mini-fragment plate fixation of midshaft clavicle fractures is biomechanically equivalent to anatomic pre-contoured plating.
    Ferguson DP; Baker HP; Dillman D; Theriault P; Trask K; MacDonald S; Trenholm A
    Eur J Orthop Surg Traumatol; 2023 May; 33(4):1109-1116. PubMed ID: 35412150
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Low-Profile Dual Small Plate Fixation Is Biomechanically Similar to Larger Superior or Anteroinferior Single Plate Fixation of Midshaft Clavicle Fractures.
    Ziegler CG; Aman ZS; Storaci HW; Finch H; Dornan GJ; Kennedy MI; Provencher MT; Hackett TR
    Am J Sports Med; 2019 Sep; 47(11):2678-2685. PubMed ID: 31381363
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Biomechanical Analysis of Superior and Anterior Precontoured Plate Fixation Techniques for Neer Type II-A Clavicle Fractures.
    Worhacz K; Nayak AN; Boudreaux RL; Pavan B; Wipf Dipl-Ing F; Jacofsky MC; Araghi A
    J Orthop Trauma; 2018 Dec; 32(12):e462-e468. PubMed ID: 30252778
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Dual mini-fragment plating for midshaft clavicle fractures: a clinical and biomechanical investigation.
    Prasarn ML; Meyers KN; Wilkin G; Wellman DS; Chan DB; Ahn J; Lorich DG; Helfet DL
    Arch Orthop Trauma Surg; 2015 Dec; 135(12):1655-62. PubMed ID: 26377733
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Do Transcortical Screws in a Locking Plate Construct Improve the Stiffness in the Fixation of Vancouver B1 Periprosthetic Femur Fractures? A Biomechanical Analysis of 2 Different Plating Constructs.
    Lochab J; Carrothers A; Wong E; McLachlin S; Aldebeyan W; Jenkinson R; Whyne C; Nousiainen MT
    J Orthop Trauma; 2017 Jan; 31(1):15-20. PubMed ID: 28002219
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Comparison of a novel hybrid hook locking plate fixation method with the conventional AO hook plate fixation method for Neer type V distal clavicle fractures.
    Seo J; Heo K; Kim SJ; Kim JK; Ham HJ; Yoo J
    Orthop Traumatol Surg Res; 2020 Feb; 106(1):67-75. PubMed ID: 31826826
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Biomechanical and clinical evaluation of minimal invasive plate osteosynthesis for two-part clavicle shaft fractures.
    Schlüßler A; Fehrenbacher M; Richter RF; Tille E; Biewener A; Nowotny J
    BMC Musculoskelet Disord; 2023 Jul; 24(1):612. PubMed ID: 37491249
    [TBL] [Abstract][Full Text] [Related]  

  • 17. New generation of superior single plating vs. low-profile dual minifragment plating in diaphyseal clavicle fractures: a biomechanical comparative study.
    Pastor T; Zderic I; Berk T; Souleiman F; Vögelin E; Beeres FJP; Gueorguiev B; Pastor T
    J Shoulder Elbow Surg; 2024 Feb; 33(2):409-416. PubMed ID: 37748530
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Dual plating for fixation failure of the distal femur: Finite element analysis and a clinical series.
    Jitprapaikulsarn S; Chantarapanich N; Gromprasit A; Mahaisavariya C; Sukha K; Chiawchan S
    Med Eng Phys; 2023 Jan; 111():103926. PubMed ID: 36792233
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Canceling Notch Improves the Mechanical Safety of Clavicle Locking Plate: A 3D Finite Element Study.
    Han Z; Luo Q; Deng G; Bi C; Yin G; Lin H; Wu J; Wu X
    Orthop Surg; 2023 Aug; 15(8):2152-2156. PubMed ID: 36349872
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Femoral periprosthetic fracture treatment using the Ortho-Bridge System: a biomechanical study.
    Long Y; Qi Y; Zuo G; Zhang Q; Liu Z; Wang W
    J Orthop Surg Res; 2022 Jun; 17(1):301. PubMed ID: 35659004
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.