These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

127 related articles for article (PubMed ID: 38251647)

  • 1. Comparison of Pre- and Post-DMEK Keratometry and Total Keratometry Values for IOL Power Calculations in Eyes Undergoing Triple DMEK.
    Rangu N; Cooke DL; Mittal A; Reinhard T; Wacker K; Langenbucher A; Wendelstein JA; Riaz KM
    Curr Eye Res; 2024 May; 49(5):477-486. PubMed ID: 38251647
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Standard vs total keratometry for intraocular lens power calculation in cataract surgery combined with DMEK.
    Khan A; Rangu N; Murphy DA; Cooke DL; Siatkowski RL; Mittal A; Wendelstein JA; Riaz KM
    J Cataract Refract Surg; 2023 Mar; 49(3):239-245. PubMed ID: 36804866
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Lower refractive prediction accuracy of total keratometry using intraocular lens formulas loaded onto a swept-source optical biometer.
    Danjo Y; Ohji R; Maeno S
    Graefes Arch Clin Exp Ophthalmol; 2023 Jan; 261(1):137-146. PubMed ID: 35881200
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Intraocular Lens Power Calculations in Keratoconus Eyes Comparing Keratometry, Total Keratometry, and Newer Formulae.
    Heath MT; Mulpuri L; Kimiagarov E; Patel RP; Murphy DA; Levine H; Tonk RS; Cooke DL; Riaz KM
    Am J Ophthalmol; 2023 Sep; 253():206-214. PubMed ID: 37044197
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Comparison of refractive outcomes using conventional keratometry or total keratometry for IOL power calculation in cataract surgery.
    Srivannaboon S; Chirapapaisan C
    Graefes Arch Clin Exp Ophthalmol; 2019 Dec; 257(12):2677-2682. PubMed ID: 31486917
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Accuracy of refractive outcomes using standard or total keratometry for intraocular lens power formulas in conventional cataract surgery.
    Zhao H; Chen X; Liu B; Liu X; Liu Y
    BMC Ophthalmol; 2023 Aug; 23(1):346. PubMed ID: 37544987
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Effect of Posterior Keratometry on the Accuracy of 10 Intraocular Lens Calculation Formulas: Standard Keratometry versus Total Keratometry.
    Jin A; Zhang J; Tan X; Jin K; Zhang Y; Han X; Chen X; Jin G; Luo L; Liu Y
    Graefes Arch Clin Exp Ophthalmol; 2024 Jun; 262(6):1829-1838. PubMed ID: 38197993
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Accuracy of intraocular lens formulas using total keratometry in eyes with previous myopic laser refractive surgery.
    Yeo TK; Heng WJ; Pek D; Wong J; Fam HB
    Eye (Lond); 2021 Jun; 35(6):1705-1711. PubMed ID: 32868880
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Total keratometry in intraocular lens power calculations in eyes with previous laser refractive surgery.
    Lawless M; Jiang JY; Hodge C; Sutton G; Roberts TV; Barrett G
    Clin Exp Ophthalmol; 2020 Aug; 48(6):749-756. PubMed ID: 32279436
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Evaluation of total keratometry and its accuracy for intraocular lens power calculation in eyes after corneal refractive surgery.
    Wang L; Spektor T; de Souza RG; Koch DD
    J Cataract Refract Surg; 2019 Oct; 45(10):1416-1421. PubMed ID: 31399324
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Accuracy of Intraocular Lens Power Calculation Based on Total Keratometry in Patients With Flat and Steep Corneas.
    Qin Y; Liu L; Mao Y; Ding Y; Ye S; Sun A; Wu M
    Am J Ophthalmol; 2023 Mar; 247():103-110. PubMed ID: 36375590
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Optimizing intraocular lens power calculation using adjusted conventional keratometry for cataract surgery combined with Descemet membrane endothelial keratoplasty.
    Diener R; Treder M; Lauermann JL; Eter N; Alnawaiseh M
    Graefes Arch Clin Exp Ophthalmol; 2022 Sep; 260(9):3087-3093. PubMed ID: 35258717
    [TBL] [Abstract][Full Text] [Related]  

  • 13. [Accuracy comparison of total keratometry and standard keratometry in intraocular lens power calculations for post-corneal refractive surgery cataract patients].
    Wang XC; Su WJ; Ge JJ; Huang YS
    Zhonghua Yan Ke Za Zhi; 2024 Aug; 60(8):689-694. PubMed ID: 39085159
    [No Abstract]   [Full Text] [Related]  

  • 14. Refractive accuracy in eyes undergoing combined cataract extraction and Descemet membrane endothelial keratoplasty.
    Campbell JA; Ladas JG; Wang K; Woreta F; Srikumaran D
    Br J Ophthalmol; 2022 May; 106(5):623-627. PubMed ID: 33414244
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Comparison of intraocular lens power calculation formulas with and without total keratometry and ray tracing in patients with previous myopic SMILE.
    Meziane Elotmani A; Messerschmidt-Roth A; Nehme A; Müller HH; Sekundo W
    J Cataract Refract Surg; 2023 May; 49(5):467-473. PubMed ID: 36700932
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Prediction Accuracy of Total Keratometry Compared to Standard Keratometry Using Different Intraocular Lens Power Formulas.
    Fabian E; Wehner W
    J Refract Surg; 2019 Jun; 35(6):362-368. PubMed ID: 31185101
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Comparison of the Barrett Universal II formula to previous generation formulae for paediatric cataract surgery.
    Elbaz U; Khalili S; Sella R; Reitblat O; Vega Y; Achiron A; Tuuminen R; Ali A; Mireskandari K
    Acta Ophthalmol; 2022 Sep; 100(6):682-689. PubMed ID: 34766439
    [TBL] [Abstract][Full Text] [Related]  

  • 18. The effect of corneal power on the accuracy of 14 IOL power formulas.
    Xu J; Zhang L; Mo E; Zhu K; Zhu Y; Feng K; Wu Z; Zheng Y; Huang F; Gong X; Li J
    BMC Ophthalmol; 2024 Mar; 24(1):126. PubMed ID: 38504225
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Accuracy of 12 Intraocular Lens Power Formulas After Corneal Myopic Refractive Surgery.
    Rong X; Liu J; Jiang L; Wang X; Feng T; Lu Z; Fan Z; Yan H
    J Refract Surg; 2024 May; 40(6):e354-e361. PubMed ID: 38848053
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Prediction accuracy of conventional and total keratometry for intraocular lens power calculation in femtosecond laser-assisted cataract surgery.
    Ryu S; Jun I; Kim TI; Seo KY; Kim EK
    Sci Rep; 2021 Jun; 11(1):12869. PubMed ID: 34145357
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.