These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

136 related articles for article (PubMed ID: 38257515)

  • 1. Sensor-to-Bone Calibration with the Fusion of IMU and Bi-Plane X-rays.
    Gasparutto X; Rose-Dulcina K; Grouvel G; DiGiovanni P; Carcreff L; Hannouche D; Armand S
    Sensors (Basel); 2024 Jan; 24(2):. PubMed ID: 38257515
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Three-Dimensional Lower-Limb Kinematics from Accelerometers and Gyroscopes with Simple and Minimal Functional Calibration Tasks: Validation on Asymptomatic Participants.
    Carcreff L; Payen G; Grouvel G; Massé F; Armand S
    Sensors (Basel); 2022 Jul; 22(15):. PubMed ID: 35957218
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Gait kinematics based on inertial measurement units with the sensor-to-segment calibration and multibody optimization adapted to the patient's motor capacities, a pilot study.
    Pacher L; Carcreff L; Armand S; Chatellier C; Vauzelle R; Fradet L
    Gait Posture; 2024 Feb; 108():275-281. PubMed ID: 38171183
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Concurrent validity and within-session reliability of gait kinematics measured using an inertial motion capture system with repeated calibration.
    Berner K; Cockcroft J; Morris LD; Louw Q
    J Bodyw Mov Ther; 2020 Oct; 24(4):251-260. PubMed ID: 33218520
    [TBL] [Abstract][Full Text] [Related]  

  • 5. IMU-based sensor-to-segment multiple calibration for upper limb joint angle measurement-a proof of concept.
    Zabat M; Ababou A; Ababou N; Dumas R
    Med Biol Eng Comput; 2019 Nov; 57(11):2449-2460. PubMed ID: 31471784
    [TBL] [Abstract][Full Text] [Related]  

  • 6. In-vitro validation of inertial-sensor-to-bone alignment.
    Weygers I; Kok M; Seel T; Shah D; Taylan O; Scheys L; Hallez H; Claeys K
    J Biomech; 2021 Nov; 128():110781. PubMed ID: 34628197
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Validity of inertial sensor based 3D joint kinematics of static and dynamic sport and physiotherapy specific movements.
    Teufl W; Miezal M; Taetz B; Fröhlich M; Bleser G
    PLoS One; 2019; 14(2):e0213064. PubMed ID: 30817787
    [TBL] [Abstract][Full Text] [Related]  

  • 8. An IMU-to-Body Alignment Method Applied to Human Gait Analysis.
    Vargas-Valencia LS; Elias A; Rocon E; Bastos-Filho T; Frizera A
    Sensors (Basel); 2016 Dec; 16(12):. PubMed ID: 27973406
    [TBL] [Abstract][Full Text] [Related]  

  • 9. On Inertial Body Tracking in the Presence of Model Calibration Errors.
    Miezal M; Taetz B; Bleser G
    Sensors (Basel); 2016 Jul; 16(7):. PubMed ID: 27455266
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Reliability in measurement of three-dimensional anterior pelvic plane orientation by registration with an inertial measurement unit.
    Kim K; Wei R; Kim YH
    Front Surg; 2022; 9():1011432. PubMed ID: 36532128
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Inertial Measurement Unit Sensor-to-Segment Calibration Comparison for Sport-Specific Motion Analysis.
    Ekdahl M; Loewen A; Erdman A; Sahin S; Ulman S
    Sensors (Basel); 2023 Sep; 23(18):. PubMed ID: 37766040
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Optimization of IMU Sensor Placement for the Measurement of Lower Limb Joint Kinematics.
    Niswander W; Wang W; Kontson K
    Sensors (Basel); 2020 Oct; 20(21):. PubMed ID: 33105876
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Does IMU redundancy improve multi-body optimization results to obtain lower-body kinematics? A preliminary study says no.
    Couvertier M; Pacher L; Fradet L
    J Biomech; 2024 May; 168():112091. PubMed ID: 38640829
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Validity of Inertial Measurement Units to Measure Lower-Limb Kinematics and Pelvic Orientation at Submaximal and Maximal Effort Running Speeds.
    Lin YC; Price K; Carmichael DS; Maniar N; Hickey JT; Timmins RG; Heiderscheit BC; Blemker SS; Opar DA
    Sensors (Basel); 2023 Dec; 23(23):. PubMed ID: 38067972
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Lower Limb Kinematics Using Inertial Sensors during Locomotion: Accuracy and Reproducibility of Joint Angle Calculations with Different Sensor-to-Segment Calibrations.
    Lebleu J; Gosseye T; Detrembleur C; Mahaudens P; Cartiaux O; Penta M
    Sensors (Basel); 2020 Jan; 20(3):. PubMed ID: 32012906
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Inertial Sensor-to-Segment Calibration for Accurate 3D Joint Angle Calculation for Use in OpenSim.
    Di Raimondo G; Vanwanseele B; van der Have A; Emmerzaal J; Willems M; Killen BA; Jonkers I
    Sensors (Basel); 2022 Apr; 22(9):. PubMed ID: 35590949
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Validation of inertial measurement units with optical tracking system in patients operated with Total hip arthroplasty.
    Zügner R; Tranberg R; Timperley J; Hodgins D; Mohaddes M; Kärrholm J
    BMC Musculoskelet Disord; 2019 Feb; 20(1):52. PubMed ID: 30727979
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Validation of Novel Relative Orientation and Inertial Sensor-to-Segment Alignment Algorithms for Estimating 3D Hip Joint Angles.
    Adamowicz L; Gurchiek RD; Ferri J; Ursiny AT; Fiorentino N; McGinnis RS
    Sensors (Basel); 2019 Nov; 19(23):. PubMed ID: 31771263
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Using Inertial Measurement Unit Sensor Single Axis Rotation Angles for Knee and Hip Flexion Angle Calculations During Gait.
    Oliveira N; Park J; Barrance P
    IEEE J Transl Eng Health Med; 2023; 11():80-86. PubMed ID: 36704243
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Fetlock Joint Angle Pattern and Range of Motion Quantification Using Two Synchronized Wearable Inertial Sensors per Limb in Sound Horses and Horses with Single Limb Naturally Occurring Lameness.
    Pagliara E; Marenchino M; Antenucci L; Costantini M; Zoppi G; Giacobini MDL; Bullone M; Riccio B; Bertuglia A
    Vet Sci; 2022 Aug; 9(9):. PubMed ID: 36136672
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.