These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

114 related articles for article (PubMed ID: 3826325)

  • 41. Identification of low-effort patients through dynamometry.
    Stokes HM; Landrieu KW; Domangue B; Kunen S
    J Hand Surg Am; 1995 Nov; 20(6):1047-56. PubMed ID: 8583056
    [TBL] [Abstract][Full Text] [Related]  

  • 42. Measurement of grip strength: validity and reliability of the sphygmomanometer and jamar grip dynamometer.
    Hamilton GF; McDonald C; Chenier TC
    J Orthop Sports Phys Ther; 1992; 16(5):215-9. PubMed ID: 18796752
    [TBL] [Abstract][Full Text] [Related]  

  • 43. Age trajectories of grip strength: cross-sectional and longitudinal data among 8,342 Danes aged 46 to 102.
    Frederiksen H; Hjelmborg J; Mortensen J; McGue M; Vaupel JW; Christensen K
    Ann Epidemiol; 2006 Jul; 16(7):554-62. PubMed ID: 16406245
    [TBL] [Abstract][Full Text] [Related]  

  • 44. The injured upper extremity and the JAMAR five-handle position grip test.
    Goldman S; Cahalan TD; An KN
    Am J Phys Med Rehabil; 1991 Dec; 70(6):306-8. PubMed ID: 1742000
    [TBL] [Abstract][Full Text] [Related]  

  • 45. Hand span influences optimal grip span in male and female teenagers.
    Ruiz JR; España-Romero V; Ortega FB; Sjöström M; Castillo MJ; Gutierrez A
    J Hand Surg Am; 2006 Oct; 31(8):1367-72. PubMed ID: 17027801
    [TBL] [Abstract][Full Text] [Related]  

  • 46. Relationship between grip strength and hand bone mineral density in healthy adults.
    Kaya A; Ozgocmen S; Ardicoglu O; Kamanli A; Gudul H
    Arch Med Res; 2005; 36(5):603-6. PubMed ID: 16099346
    [TBL] [Abstract][Full Text] [Related]  

  • 47. Grip strength as measured by the Jamar dynamometer.
    Schmidt RT; Toews JV
    Arch Phys Med Rehabil; 1970 Jun; 51(6):321-7. PubMed ID: 5423802
    [No Abstract]   [Full Text] [Related]  

  • 48. A practical posture for hand grip dynamometry in the clinical setting.
    Hillman TE; Nunes QM; Hornby ST; Stanga Z; Neal KR; Rowlands BJ; Allison SP; Lobo DN
    Clin Nutr; 2005 Apr; 24(2):224-8. PubMed ID: 15784482
    [TBL] [Abstract][Full Text] [Related]  

  • 49. Strength measurements of the intrinsic hand muscles: a review of the development and evaluation of the Rotterdam intrinsic hand myometer.
    Schreuders TA; Selles RW; Roebroeck ME; Stam HJ
    J Hand Ther; 2006; 19(4):393-401; quiz 402. PubMed ID: 17056399
    [TBL] [Abstract][Full Text] [Related]  

  • 50. Grip and pinch strength in relation to function in denervated hands.
    Rajkumar P; Premkumar R; Richard J
    Indian J Lepr; 2002; 74(4):319-28. PubMed ID: 12624980
    [TBL] [Abstract][Full Text] [Related]  

  • 51. Assessing sincerity of effort in maximal grip strength tests.
    Chengalur SN; Smith GA; Nelson RC; Sadoff AM
    Am J Phys Med Rehabil; 1990 Jun; 69(3):148-53. PubMed ID: 2363907
    [TBL] [Abstract][Full Text] [Related]  

  • 52. Hand span influences optimal grip span in boys and girls aged 6 to 12 years.
    España-Romero V; Artero EG; Santaliestra-Pasias AM; Gutierrez A; Castillo MJ; Ruiz JR
    J Hand Surg Am; 2008 Mar; 33(3):378-84. PubMed ID: 18343294
    [TBL] [Abstract][Full Text] [Related]  

  • 53. Identifying sincerity of effort by grip strength ratio of three wrist positions in individuals with upper extremity musculoskeletal disorders.
    Nanta P; Bhuanantanondh P
    J Occup Health; 2021 Jan; 63(1):e12295. PubMed ID: 34780083
    [TBL] [Abstract][Full Text] [Related]  

  • 54. Effectiveness of the five-handle position grip strength test in detecting sincerity of effort in men and women.
    Gutierrez Z; Shechtman O
    Am J Phys Med Rehabil; 2003 Nov; 82(11):847-55. PubMed ID: 14566152
    [TBL] [Abstract][Full Text] [Related]  

  • 55. Using the "visual target grip test" to identify sincerity of effort during grip strength testing.
    Shechtman O; Sindhu BS; Davenport PW
    J Hand Ther; 2012; 25(3):320-8; quiz 329. PubMed ID: 22483342
    [TBL] [Abstract][Full Text] [Related]  

  • 56. Grip strength and hand position of the dynamometer in 204 Finnish adults.
    Härkönen R; Piirtomaa M; Alaranta H
    J Hand Surg Br; 1993 Feb; 18(1):129-32. PubMed ID: 8436850
    [TBL] [Abstract][Full Text] [Related]  

  • 57. Grip strength testing reliability.
    Hamilton A; Balnave R; Adams R
    J Hand Ther; 1994; 7(3):163-70. PubMed ID: 7951708
    [TBL] [Abstract][Full Text] [Related]  

  • 58. Using the force-time curve to determine sincerity of effort in people with upper extremity injuries.
    Sindhu BS; Shechtman O
    J Hand Ther; 2011; 24(1):22-9; quiz 30. PubMed ID: 21050713
    [TBL] [Abstract][Full Text] [Related]  

  • 59. Determining Sincerity of Effort Based on Grip Strength Test in Three Wrist Positions.
    Bhuanantanondh P; Nanta P; Mekhora K
    Saf Health Work; 2018 Mar; 9(1):59-62. PubMed ID: 30363064
    [TBL] [Abstract][Full Text] [Related]  

  • 60. Detection of submaximal effort by use of the rapid exchange grip.
    Hildreth DH; Breidenbach WC; Lister GD; Hodges AD
    J Hand Surg Am; 1989 Jul; 14(4):742-5. PubMed ID: 2526835
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 6.