These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

157 related articles for article (PubMed ID: 38264680)

  • 1. Influence of Abutment Screw-Tightening Methods on the Screw Joint: Immediate and Long-Term Stability.
    Sun M; Shui Y; Zhang Y; Ma R; Zhao Y; Chen H; Yu P; Li Z; Wu T; Yu H
    Int J Dent; 2024; 2024():5768318. PubMed ID: 38264680
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Loosening torque of Universal Abutment screws after cyclic loading: influence of tightening technique and screw coating.
    Bacchi A; Regalin A; Bhering CL; Alessandretti R; Spazzin AO
    J Adv Prosthodont; 2015 Oct; 7(5):375-9. PubMed ID: 26576253
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Effect of Repeated Screw Joint Closing and Opening Cycles and Cyclic Loading on Abutment Screw Removal Torque and Screw Thread Morphology: Scanning Electron Microscopy Evaluation.
    Arshad M; Mahgoli H; Payaminia L
    Int J Oral Maxillofac Implants; 2018; 33(1):31–40. PubMed ID: 28938027
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Screw joint stability after the application of retorque in implant-supported dentures under simulated masticatory conditions.
    Farina AP; Spazzin AO; Consani RL; Mesquita MF
    J Prosthet Dent; 2014 Jun; 111(6):499-504. PubMed ID: 24423456
    [TBL] [Abstract][Full Text] [Related]  

  • 5. In Vitro Study of Preload Loss in Different Implant Abutment Connection Designs.
    Vinhas AS; Aroso C; Salazar F; Relvas M; Braga AC; Ríos-Carrasco B; Gil J; Rios-Santos JV; Fernández-Palacín A; Herrero-Climent M
    Materials (Basel); 2022 Feb; 15(4):. PubMed ID: 35207933
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Clinical Assessment of Preload Maintenance in the Abutment Screws of Single Posterior Implants After 1 Month of Use.
    Xu Y; Li W; Su M
    Int J Oral Maxillofac Implants; 2021; 36(1):177-181. PubMed ID: 33600539
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Dynamic fatigue performance of implant-abutment assemblies with different tightening torque values.
    Xia D; Lin H; Yuan S; Bai W; Zheng G
    Biomed Mater Eng; 2014; 24(6):2143-9. PubMed ID: 25226912
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Preloads generated with repeated tightening in three types of screws used in dental implant assemblies.
    Byrne D; Jacobs S; O'Connell B; Houston F; Claffey N
    J Prosthodont; 2006; 15(3):164-71. PubMed ID: 16681498
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Effect of implant abutment connection designs, and implant diameters on screw loosening before and after cyclic loading: In-vitro study.
    Sammour SR; Maamoun El-Sheikh M; Aly El-Gendy A
    Dent Mater; 2019 Nov; 35(11):e265-e271. PubMed ID: 31427043
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Comparison of the Effect of Four Different Abutment Screw Torques on Screw Loosening in Single Implant-Supported Prosthesis after the Application of Mechanical Loading.
    Ebadian B; Fathi A; Khodadad S
    Int J Dent; 2021; 2021():3595064. PubMed ID: 34335769
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Finite element analysis to determine implant preload.
    Lang LA; Kang B; Wang RF; Lang BR
    J Prosthet Dent; 2003 Dec; 90(6):539-46. PubMed ID: 14668754
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Effect of Different Retightening Procedures on Screw Stability in External-Hex and Internal Trichannel Connections: An In Vitro Study.
    Sun J; Yoda N; Matsudate Y; Hong G; Kawata T; Sasaki K
    Int J Prosthodont; 2023 May; 36(2):181-188. PubMed ID: 33662065
    [TBL] [Abstract][Full Text] [Related]  

  • 13. The Effect of Torque Application Technique on Screw Preload of Implant-Supported Prostheses.
    Al-Otaibi HN; Almutairi A; Alfarraj J; Algesadi W
    Int J Oral Maxillofac Implants; 2017; 32(2):259–263. PubMed ID: 27632154
    [TBL] [Abstract][Full Text] [Related]  

  • 14. The Relationship Between Time of Retightening and Preload Loss of Abutment Screws for Two Different Implant Designs: An In Vitro Study.
    Varvara G; Sinjari B; Caputi S; Scarano A; Piattelli M
    J Oral Implantol; 2020 Feb; 46(1):13-17. PubMed ID: 31580759
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Critical bending moment of implant-abutment screw joint interfaces: effect of torque levels and implant diameter.
    Tan BF; Tan KB; Nicholls JI
    Int J Oral Maxillofac Implants; 2004; 19(5):648-58. PubMed ID: 15508980
    [TBL] [Abstract][Full Text] [Related]  

  • 16. In vitro evaluation of reverse torque value of abutment screw and marginal opening in a screw- and cement-retained implant fixed partial denture design.
    Kim SG; Park JU; Jeong JH; Bae C; Bae TS; Chee W
    Int J Oral Maxillofac Implants; 2009; 24(6):1061-7. PubMed ID: 20162110
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Evaluation of implant abutment screw tightening protocols on reverse tightening values: An in vitro study.
    Alnasser AH; Wadhwani CPK; Schoenbaum TR; Kattadiyil MT
    J Prosthet Dent; 2021 Mar; 125(3):486-490. PubMed ID: 32416983
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Wave analysis of implant screw loosening using an air cylindrical cyclic loading device.
    Lee J; Kim YS; Kim CW; Han JS
    J Prosthet Dent; 2002 Oct; 88(4):402-8. PubMed ID: 12447217
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Influence of Anodizing Stages on the Preload Force of Implant-Abutment Screws and Their Benefits Regarding the Concept of Immediate Implant Placement-An In Vitro Study.
    Rathe F; Weigl P; Wasiak J; Ratka C; Zipprich H
    Materials (Basel); 2022 Jan; 15(3):. PubMed ID: 35160721
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Loss of preload in screwed implant joints as a function of time and tightening/untightening sequences.
    Bernardes SR; da Gloria Chiarello de Mattos M; Hobkirk J; Ribeiro RF
    Int J Oral Maxillofac Implants; 2014; 29(1):89-96. PubMed ID: 24451858
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.