176 related articles for article (PubMed ID: 38270168)
1. Intracochlear Trauma and Local Ossification Patterns Differ Between Straight and Precurved Cochlear Implant Electrodes.
Geerardyn A; Zhu M; Verhaert N; Quesnel AM
Otol Neurotol; 2024 Mar; 45(3):245-255. PubMed ID: 38270168
[TBL] [Abstract][Full Text] [Related]
2. Human Histology after Structure Preservation Cochlear Implantation via Round Window Insertion.
Geerardyn A; Zhu M; Klabbers T; Huinck W; Mylanus E; Nadol JB; Verhaert N; Quesnel AM
Laryngoscope; 2024 Feb; 134(2):945-953. PubMed ID: 37493203
[TBL] [Abstract][Full Text] [Related]
3. Surgical trauma after sequential insertion of intracochlear catheters and electrode arrays (a histologic study).
Ibrahim HN; Helbig S; Bossard D; Truy E
Otol Neurotol; 2011 Dec; 32(9):1448-54. PubMed ID: 22072260
[TBL] [Abstract][Full Text] [Related]
4. Assessment of intracochlear trauma caused by the insertion of a new straight research array.
Mukherjee P; Uzun-Coruhlu H; Wong CC; Curthoys IS; Jones AS; Gibson WP
Cochlear Implants Int; 2012 Aug; 13(3):156-62. PubMed ID: 22333934
[TBL] [Abstract][Full Text] [Related]
5. A temporal bone study of insertion trauma and intracochlear position of cochlear implant electrodes. II: Comparison of Spiral Clarion and HiFocus II electrodes.
Wardrop P; Whinney D; Rebscher SJ; Luxford W; Leake P
Hear Res; 2005 May; 203(1-2):68-79. PubMed ID: 15855031
[TBL] [Abstract][Full Text] [Related]
6. Factors associated with incomplete insertion of electrodes in cochlear implant surgery: a histopathologic study.
Lee J; Nadol JB; Eddington DK
Audiol Neurootol; 2011; 16(2):69-81. PubMed ID: 20571258
[TBL] [Abstract][Full Text] [Related]
7. A temporal bone study of insertion trauma and intracochlear position of cochlear implant electrodes. I: Comparison of Nucleus banded and Nucleus Contour electrodes.
Wardrop P; Whinney D; Rebscher SJ; Roland JT; Luxford W; Leake PA
Hear Res; 2005 May; 203(1-2):54-67. PubMed ID: 15855030
[TBL] [Abstract][Full Text] [Related]
8. Insertion forces and intracochlear trauma in temporal bone specimens implanted with a straight atraumatic electrode array.
Mirsalehi M; Rau TS; Harbach L; Hügl S; Mohebbi S; Lenarz T; Majdani O
Eur Arch Otorhinolaryngol; 2017 May; 274(5):2131-2140. PubMed ID: 28238160
[TBL] [Abstract][Full Text] [Related]
9. Correlation between word recognition score and intracochlear new bone and fibrous tissue after cochlear implantation in the human.
Kamakura T; Nadol JB
Hear Res; 2016 Sep; 339():132-41. PubMed ID: 27371868
[TBL] [Abstract][Full Text] [Related]
10. [Evaluation of the insertion-trauma of the Nucleus Contour Advance electrode-array in a human temporal bone model].
Klenzner T; Richter B; Nagursky H; Schipper J; Laszig R; Aschendorff A
Laryngorhinootologie; 2004 Dec; 83(12):840-4. PubMed ID: 15611904
[TBL] [Abstract][Full Text] [Related]
11. [Intracochlear position of cochlear implant electrodes].
Gstoettner W; Hamzavi J; Franz P; Plenk H; Czerny C; Susani M; Adunka O; Baumgartner WD
Wien Klin Wochenschr; 2000 Jun; 112(11):477-80. PubMed ID: 10890124
[TBL] [Abstract][Full Text] [Related]
12. Three-dimensional quantification of fibrosis and ossification after cochlear implantation via virtual re-sectioning: Potential implications for residual hearing.
Geerardyn A; Zhu M; Wu P; O'Malley J; Nadol JB; Liberman MC; Nakajima HH; Verhaert N; Quesnel AM
Hear Res; 2023 Feb; 428():108681. PubMed ID: 36584546
[TBL] [Abstract][Full Text] [Related]
13. Cochlear implant explantation: An in vitro model to evaluate electrode explant force and trauma.
Asfour L; Risi F; Miah H; Roland JT
Cochlear Implants Int; 2022 Jul; 23(4):189-194. PubMed ID: 35236258
[TBL] [Abstract][Full Text] [Related]
14. Three-Dimensional Force Profile During Cochlear Implantation Depends on Individual Geometry and Insertion Trauma.
Avci E; Nauwelaers T; Hamacher V; Kral A
Ear Hear; 2017; 38(3):e168-e179. PubMed ID: 28045786
[TBL] [Abstract][Full Text] [Related]
15. Validation of minimally invasive, image-guided cochlear implantation using Advanced Bionics, Cochlear, and Medel electrodes in a cadaver model.
McRackan TR; Balachandran R; Blachon GS; Mitchell JE; Noble JH; Wright CG; Fitzpatrick JM; Dawant BM; Labadie RF
Int J Comput Assist Radiol Surg; 2013 Nov; 8(6):989-95. PubMed ID: 23633113
[TBL] [Abstract][Full Text] [Related]
16. The internal dimensions of the cochlear scalae with special reference to cochlear electrode insertion trauma.
Biedron S; Prescher A; Ilgner J; Westhofen M
Otol Neurotol; 2010 Jul; 31(5):731-7. PubMed ID: 20142798
[TBL] [Abstract][Full Text] [Related]
17. Insertion trauma of a new cochlear implant electrode: evaluated by histology in fresh human temporal bone specimens.
Du Q; Wang C; He G; Sun Z
Acta Otolaryngol; 2021 May; 141(5):490-494. PubMed ID: 33784954
[TBL] [Abstract][Full Text] [Related]
18. Round window insertion of precurved electrodes is traumatic.
Jeyakumar A; Peña SF; Brickman TM
Otol Neurotol; 2014 Jan; 35(1):52-7. PubMed ID: 24270713
[TBL] [Abstract][Full Text] [Related]
19. Does cochleostomy location influence electrode trajectory and intracochlear trauma?
Zhou L; Friedmann DR; Treaba C; Peng R; Roland JT
Laryngoscope; 2015 Apr; 125(4):966-71. PubMed ID: 25345671
[TBL] [Abstract][Full Text] [Related]
20. Evaluating Intracochlear Trauma after Cochlear Implant Electrode Insertion through Middle Fossa Approach in Temporal Bones.
Cisneros Lesser JC; de Brito R; Queiroz Martins GS; Gebrim EMMS; Bento RF
Otolaryngol Head Neck Surg; 2018 Feb; 158(2):350-357. PubMed ID: 29088548
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]