These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

233 related articles for article (PubMed ID: 38270670)

  • 1. Versatility of reverse transcriptase loop-mediated isothermal amplification (RT-LAMP) from diagnosis of early pathological infection to mutation detection in organisms.
    Sen S; Bhowmik P; Tiwari S; Peleg Y; Bandyopadhyay B
    Mol Biol Rep; 2024 Jan; 51(1):211. PubMed ID: 38270670
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Immunocapture-Reverse Transcriptase Loop-Mediated Isothermal Amplification Assay for Detection of Plant RNA Viruses.
    Hajeri S; Yokomi R
    Methods Mol Biol; 2022; 2400():245-252. PubMed ID: 34905207
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Detection of human Enterovirus 71 reverse transcription loop-mediated isothermal amplification (RT-LAMP).
    Yaqing H; Wenping Z; Zhiyi Y; Xionghu W; Shouyi Y; Hong Y; Yingchun D; Guifang H
    Lett Appl Microbiol; 2012 Mar; 54(3):233-9. PubMed ID: 22256968
    [TBL] [Abstract][Full Text] [Related]  

  • 4. A Multiplex and Colorimetric Reverse Transcription Loop-Mediated Isothermal Amplification Assay for Sensitive and Rapid Detection of Novel SARS-CoV-2.
    Juscamayta-López E; Valdivia F; Horna H; Tarazona D; Linares L; Rojas N; Huaringa M
    Front Cell Infect Microbiol; 2021; 11():653616. PubMed ID: 34268131
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Development and evaluation of reverse transcription-loop-mediated isothermal amplification assay for rapid detection of enterovirus 71.
    Shi W; Li K; Ji Y; Jiang Q; Shi M; Mi Z
    BMC Infect Dis; 2011 Jul; 11():197. PubMed ID: 21767352
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Capillary-based reverse transcriptase loop-mediated isothermal amplification for cost-effective and rapid point-of-care COVID-19 testing.
    John AJUK; He PJW; Katis IN; Galanis PP; Iles AH; Eason RW; Sones CL
    Anal Chim Acta; 2021 Nov; 1185():339002. PubMed ID: 34711332
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Reverse Transcriptase Loop Mediated Isothermal Amplification (RT-LAMP) for COVID-19 diagnosis: a systematic review and meta-analysis.
    Subali AD; Wiyono L
    Pathog Glob Health; 2021 Jul; 115(5):281-291. PubMed ID: 34086539
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Development and Clinical Application of a Rapid and Sensitive Loop-Mediated Isothermal Amplification Test for SARS-CoV-2 Infection.
    Hu X; Deng Q; Li J; Chen J; Wang Z; Zhang X; Fang Z; Li H; Zhao Y; Yu P; Li W; Wang X; Li S; Zhang L; Hou T
    mSphere; 2020 Aug; 5(4):. PubMed ID: 32848011
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Detection of SARS-CoV-2 and the L452R spike mutation using reverse transcription loop-mediated isothermal amplification plus bioluminescent assay in real-time (RT-LAMP-BART).
    Iijima T; Ando S; Kanamori D; Kuroda K; Nomura T; Tisi L; Kilgore PE; Percy N; Kohase H; Hayakawa S; Seki M; Hoshino T
    PLoS One; 2022; 17(3):e0265748. PubMed ID: 35312732
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Rapid and Visual Detection of SARS-CoV-2 Using Multiplex Reverse Transcription Loop-Mediated Isothermal Amplification Linked With Gold Nanoparticle-Based Lateral Flow Biosensor.
    Chen X; Zhou Q; Li S; Yan H; Chang B; Wang Y; Dong S
    Front Cell Infect Microbiol; 2021; 11():581239. PubMed ID: 34336708
    [TBL] [Abstract][Full Text] [Related]  

  • 11. A New Method to Detect Variants of SARS-CoV-2 Using Reverse Transcription Loop-Mediated Isothermal Amplification Combined with a Bioluminescent Assay in Real Time (RT-LAMP-BART).
    Iijima T; Sakai J; Kanamori D; Ando S; Nomura T; Tisi L; Kilgore PE; Percy N; Kohase H; Hayakawa S; Maesaki S; Hoshino T; Seki M
    Int J Mol Sci; 2023 Jun; 24(13):. PubMed ID: 37445876
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Loop mediated isothermal amplification (LAMP) assays as a rapid diagnostic for COVID-19.
    Kashir J; Yaqinuddin A
    Med Hypotheses; 2020 Aug; 141():109786. PubMed ID: 32361529
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Rapid detection of duck hepatitis A virus genotype C using reverse transcription loop-mediated isothermal amplification.
    Li C; Chen Z; Meng C; Liu G
    J Virol Methods; 2014 Feb; 196():193-8. PubMed ID: 24291148
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Elimination of Carryover Contamination in Real-Time Reverse Transcriptase Loop-Mediated Isothermal Amplification for Rapid Detection of the SARS-CoV-2 Virus in Point-of-Care Testing.
    Quyen TL; Vinayaka AC; Golabi M; Ngoc HV; Bang DD; Wolff A
    Front Cell Infect Microbiol; 2022; 12():856553. PubMed ID: 35521217
    [TBL] [Abstract][Full Text] [Related]  

  • 15. [Detecting human respiratory syncytial virus in respiratory samples collected from children with acute respiratory infections by reverse transcription-loop mediated isothermal amplification].
    Li F; Zhao LQ; Qian Y; Deng J; Zhu RN; Sun Y; Liu LY
    Zhonghua Er Ke Za Zhi; 2013 Apr; 51(4):270-5. PubMed ID: 23927800
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Clinical evaluation of the isothermal amplification assays for the detection of four common respiratory viruses in children with pneumonia.
    Zhou H; Zhao M; Li X; Zhang D; Zhou S; Chen C; Feng Z; Ma X
    Arch Virol; 2017 May; 162(5):1311-1318. PubMed ID: 28155195
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Rapid point-of-care detection of SARS-CoV-2 using reverse transcription loop-mediated isothermal amplification (RT-LAMP).
    Mautner L; Baillie CK; Herold HM; Volkwein W; Guertler P; Eberle U; Ackermann N; Sing A; Pavlovic M; Goerlich O; Busch U; Wassill L; Huber I; Baiker A
    Virol J; 2020 Oct; 17(1):160. PubMed ID: 33087160
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Multisite Clinical Validation of Isothermal Amplification-Based SARS-CoV-2 Detection Assays Using Different Sampling Strategies.
    Desai KT; Alfaro K; Mendoza L; Faron M; Mesich B; Maza M; Dominguez R; Valenzuela A; Acosta CD; Martínez M; Felix JC; Masch R; Smith JS; Gabrilovich S; Wu T; Plump M; Novetsky AP; Einstein MH; Douglas NC; Cremer M; Wentzensen N
    Microbiol Spectr; 2021 Oct; 9(2):e0084621. PubMed ID: 34668736
    [TBL] [Abstract][Full Text] [Related]  

  • 19. A reverse transcription loop-mediated isothermal amplification for broad coverage detection of Asian and African Zika virus lineages.
    Teoh BT; Chin KL; Samsudin NI; Loong SK; Sam SS; Tan KK; Khor CS; Abd-Jamil J; Zainal N; Wilder-Smith A; Zandi K; AbuBakar S
    BMC Infect Dis; 2020 Dec; 20(1):947. PubMed ID: 33308203
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Simple and field amenable loop-mediated isothermal amplification-lateral flow dipstick assay for detection of west Nile virus in human clinical samples.
    Tomar PS; Patel S; Dash PK; Kumar JS
    J Appl Microbiol; 2022 Dec; 133(6):3512-3522. PubMed ID: 36007965
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 12.