These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

242 related articles for article (PubMed ID: 3827191)

  • 1. Investigations into negative interference by jaundiced plasma in kinetic Jaffé methods for plasma creatinine determination.
    Knapp ML; Hadid O
    Ann Clin Biochem; 1987 Jan; 24 ( Pt 1)():85-97. PubMed ID: 3827191
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Deproteinization of serum: another best approach to eliminate all forms of bilirubin interference on serum creatinine by the kinetic Jaffe reaction.
    Lolekha PH; Jaruthunyaluck S; Srisawasdi P
    J Clin Lab Anal; 2001; 15(3):116-21. PubMed ID: 11344525
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Oxidation markedly reduces bilirubin interference in the Jaffé creatinine assay.
    Rajs G; Mayer M
    Clin Chem; 1992 Dec; 38(12):2411-3. PubMed ID: 1333917
    [TBL] [Abstract][Full Text] [Related]  

  • 4. A solution to the problem of bilirubin interference with the kinetic Jaffé method for serum creatinine.
    Osberg IM; Hammond KB
    Clin Chem; 1978 Jul; 24(7):1196-7. PubMed ID: 657504
    [TBL] [Abstract][Full Text] [Related]  

  • 5. The effect of neonatal hyperbilirubinemia on the measurement of plasma creatinine.
    Feld LG; Langford DJ; Schwartz GJ
    Clin Pediatr (Phila); 1984 Mar; 23(3):154-6. PubMed ID: 6697621
    [TBL] [Abstract][Full Text] [Related]  

  • 6. [The value of pretreatment of jaundiced blood or plasma with peroxidase and hydrogen peroxide on the kinetic level of creatinine using the Jaffé technic. Use of the IL 508 analyzer].
    Nguyen Dai D; Cherruau B; Jaffray P; Yonger J
    Ann Biol Clin (Paris); 1988; 46(8):702-3. PubMed ID: 3218792
    [No Abstract]   [Full Text] [Related]  

  • 7. Comparison of techniques for minimizing interference of bilirubin on serum creatinine determined by the kinetic Jaffé reaction.
    Lolekha PH; Sritong N
    J Clin Lab Anal; 1994; 8(6):391-9. PubMed ID: 7869178
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Kinetic study of the Jaffé reaction for quantifying creatinine in serum: 1. Alkalinity controlled with NaOH.
    Pardue HL; Bacon BL; Nevius MG; Skoug JW
    Clin Chem; 1987 Feb; 33(2 Pt 1):278-85. PubMed ID: 3802512
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Development of an automated kinetic Jaffé method designed to minimise bilirubin interference in plasma creatinine assays.
    Knapp ML; Mayne PD
    Clin Chim Acta; 1987 Sep; 168(2):239-46. PubMed ID: 3677419
    [No Abstract]   [Full Text] [Related]  

  • 10. Comparison between ADVIA Chemistry systems Enzymatic Creatinine_2 method and ADVIA Chemistry systems Creatinine method (kinetic Jaffe method) for determining creatinine.
    Hermida FJ; Lorenzo MJ; Pérez A; Fernández M; Sagastagoia O; Magadán C
    Scand J Clin Lab Invest; 2014 Oct; 74(7):629-36. PubMed ID: 24988313
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Effect of ultraviolet light on creatinine measurement in jaundiced specimens.
    Nisbet JA; D'Souza R
    Clin Chim Acta; 1986 Mar; 155(3):335-9. PubMed ID: 3708860
    [No Abstract]   [Full Text] [Related]  

  • 12. Bilirubin interference in kinetic creatinine determination.
    Dorwart WV
    Clin Chem; 1979 Jan; 25(1):196-7. PubMed ID: 761368
    [No Abstract]   [Full Text] [Related]  

  • 13. Negative interference in a kinetic Jaffé method for serum creatinine determination.
    Cruickshank AM; Ballantyne FC; Shenkin A
    Ann Clin Biochem; 1988 Jan; 25 ( Pt 1)():112-3. PubMed ID: 3355083
    [No Abstract]   [Full Text] [Related]  

  • 14. [Elimination of bilirubin interference on creatinine determination (kinetic Jaffé method) using bilirubin oxidase].
    Matsushita M; Maehata E; Aoki Y
    Rinsho Byori; 1986 Jun; 34(6):694-8. PubMed ID: 3747210
    [No Abstract]   [Full Text] [Related]  

  • 15. Reevaluating the Icterus Index Cutoff of a Jaffé Creatinine Method.
    Alvarez YF; Kelliher MT; Hubbard JA; Nerenz RD; Cervinski MA
    J Appl Lab Med; 2022 Sep; 7(5):1151-1157. PubMed ID: 35899580
    [TBL] [Abstract][Full Text] [Related]  

  • 16. [A negative interference effect of pathologic levels of bilirubin on the determination of serum creatinine].
    Smrcková I; Charvát J; Malá D; Lácha J
    Cas Lek Cesk; 1999 Jun; 138(13):406-8. PubMed ID: 10566211
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Nitromethane interferes in assay of creatinine by the Jaffé reaction.
    De Leacy EA; Brown NN; Clague AE
    Clin Chem; 1989 Aug; 35(8):1772-4. PubMed ID: 2758650
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Interference by IgG paraproteins in the Jaffe method for creatinine determination.
    Datta P; Graham GA; Schoen I
    Am J Clin Pathol; 1986 Apr; 85(4):463-8. PubMed ID: 2420168
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Exogenous interferences with Jaffe creatinine assays: addition of sodium dodecyl sulfate to reagent eliminates bilirubin and total protein interference with Jaffe methods.
    Srisawasdi P; Chaichanajarernkul U; Teerakanjana N; Vanavanan S; Kroll MH
    J Clin Lab Anal; 2010; 24(3):123-33. PubMed ID: 20486190
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Complex analyte-dependent and analyte-independent interferences with conjugated bilirubin in the enzymatic phenol-aminophenazone peroxidase (PAP) method for creatinine determination.
    Eng CD; Delgado R; Kroll MH
    Eur J Clin Chem Clin Biochem; 1993 Dec; 31(12):839-50. PubMed ID: 8136416
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 13.