These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

137 related articles for article (PubMed ID: 38284629)

  • 41. Preanalytical phase in coagulation testing: state of the art in the laboratories of the Piedmont region, Italy.
    Moraglio D; Banfi G
    Scand J Clin Lab Invest; 1996 Dec; 56(8):735-42. PubMed ID: 9034355
    [TBL] [Abstract][Full Text] [Related]  

  • 42. Quality Control of Preanalytical Handling of Blood Samples for Future Research: A National Survey.
    Gils C; Nybo M
    J Appl Lab Med; 2020 Jan; 5(1):83-90. PubMed ID: 31811074
    [TBL] [Abstract][Full Text] [Related]  

  • 43. [Pneumatic tube system for transport of laboratory samples: preanalytical aspects].
    Tóth J; Lenkey Á; V Oláh A; Köteles J; Kissné Sziráki V; Kerényi A; Kappelmayer J
    Orv Hetil; 2014 Jul; 155(28):1113-20. PubMed ID: 25002315
    [TBL] [Abstract][Full Text] [Related]  

  • 44. Influence of exogenous and endogenous factors on the quality of the preanalytical stage of laboratory tests (review of literature).
    Piskunov DP; Danilova LA; Pushkin AS; Rukavishnikova SA
    Klin Lab Diagn; 2020 Dec; 65(12):778-784. PubMed ID: 33373510
    [TBL] [Abstract][Full Text] [Related]  

  • 45. Common laboratory artifacts caused by inappropriate sample collection and transport: how to get the most out of a sample.
    Gilor S; Gilor C
    Top Companion Anim Med; 2011 May; 26(2):109-18. PubMed ID: 21596350
    [TBL] [Abstract][Full Text] [Related]  

  • 46. Preanalytical Errors in a Hematology Laboratory: An Experience from a Tertiary Care Center.
    Iqbal MS; Tabassum A; Arbaeen AF; Qasem AH; Elshemi AG; Almasmoum H
    Diagnostics (Basel); 2023 Feb; 13(4):. PubMed ID: 36832079
    [TBL] [Abstract][Full Text] [Related]  

  • 47. Increased Patient Satisfaction and a Reduction in Pre-Analytical Errors Following Implementation of an Electronic Specimen Collection Module in Outpatient Phlebotomy.
    Kantartjis M; Melanson SEF; Petrides AK; Landman AB; Bates DW; Rosner BA; Goonan E; Bixho I; Tanasijevic MJ
    Lab Med; 2017 Aug; 48(3):282-289. PubMed ID: 28934512
    [TBL] [Abstract][Full Text] [Related]  

  • 48. [Pitfalls and challenges of the preanalytical phase in hematology].
    Méndez A; Bargetzi M; Huber A; Cantoni N
    Ther Umsch; 2013 Aug; 70(8):449-55. PubMed ID: 23876751
    [TBL] [Abstract][Full Text] [Related]  

  • 49. [The effect of tailored training courses in preanalytical procedures on the quality of laboratory results].
    Mäder-Porombka C; Homberg A; Hörster F; Brune M; Kilian S; Buckel B; Goldwasser R
    Z Evid Fortbild Qual Gesundhwes; 2020 Apr; 150-152():38-44. PubMed ID: 32291158
    [TBL] [Abstract][Full Text] [Related]  

  • 50. Impact of evacuated collection tube fill volume and mixing on routine coagulation testing using 2.5-ml (pediatric) tubes.
    Chuang J; Sadler MA; Witt DM
    Chest; 2004 Oct; 126(4):1262-6. PubMed ID: 15486391
    [TBL] [Abstract][Full Text] [Related]  

  • 51. Quality Indicators for Evaluating Errors in the Preanalytical Phase.
    Mehndiratta M; Pasha EH; Chandra N; Almeida EA
    J Lab Physicians; 2021 Jun; 13(2):169-174. PubMed ID: 34483565
    [No Abstract]   [Full Text] [Related]  

  • 52. Blood collection tubes as medical devices: The potential to affect assays and proposed verification and validation processes for the clinical laboratory.
    Bowen RA; Adcock DM
    Clin Biochem; 2016 Dec; 49(18):1321-1330. PubMed ID: 27765677
    [TBL] [Abstract][Full Text] [Related]  

  • 53. Stability of ribavirin concentrations depending on the type of blood collection tube and preanalytical conditions.
    Marquet P; Sauvage FL; Loustaud-Ratti V; Babany G; Rousseau A; Lachâtre G
    Ther Drug Monit; 2010 Apr; 32(2):237-41. PubMed ID: 20216114
    [TBL] [Abstract][Full Text] [Related]  

  • 54. [Quality assessment for preanalytical phase in clinical laboratory: a multicentric study].
    Salinas M; López-Garrigós M; Yago M; Ortuño M; Carratala A; Aguado C; Díaz J; Rodriguez-Borja E; Chinchilla V; Esteban A; Laíz B; Lorente MÁ; Uris J
    Rev Calid Asist; 2011; 26(4):264-8. PubMed ID: 21621440
    [TBL] [Abstract][Full Text] [Related]  

  • 55. Preanalytical error occurrence rate in clinical chemistry laboratory of a public hospital in India.
    Singla P; Parkash AA; Bhattacharjee J
    Clin Lab; 2011; 57(9-10):749-52. PubMed ID: 22029191
    [TBL] [Abstract][Full Text] [Related]  

  • 56. The cost of poor blood specimen quality and errors in preanalytical processes.
    Green SF
    Clin Biochem; 2013 Sep; 46(13-14):1175-9. PubMed ID: 23769816
    [TBL] [Abstract][Full Text] [Related]  

  • 57. Undefilled blood tube containing EDTA: Is it an inappropriate sample for HbA1c assay?
    Guven B; Benice I; Can M
    Biochem Med (Zagreb); 2023 Feb; 33(1):010901. PubMed ID: 36817854
    [TBL] [Abstract][Full Text] [Related]  

  • 58. Reduction of preanalytical errors in clinical laboratory through multiple aspects and whole course intervention measures.
    Li HY; Huang XN; Yang YC; Huang WF; Chen L; Song P; Zhang WY
    J Evid Based Med; 2014 Aug; 7(3):172-7. PubMed ID: 25154748
    [TBL] [Abstract][Full Text] [Related]  

  • 59. The Cost of Pre-Analytical Errors in INR Testing at a Tertiary-Care Hospital Laboratory: Potential for Significant Cost Savings.
    Kulkarni S; Piraino D; Strauss R; Proctor E; Waldman S; King J; Selby R
    Lab Med; 2020 May; 51(3):320-324. PubMed ID: 31586388
    [TBL] [Abstract][Full Text] [Related]  

  • 60. An abrupt rise of coagulation error messages on ACL TOP automated analysers.
    Calcoen B; Desmet K; Vermeersch P
    Biochem Med (Zagreb); 2019 Jun; 29(2):021002. PubMed ID: 31223268
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 7.