These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

117 related articles for article (PubMed ID: 38301768)

  • 21. Single side locking on the opposite of the modified Kessler tendon repair prevents gap formation and suture pull-out: a biomechanical evaluation in sheep tendons.
    Doğramaci Y; Kalaci A; Sevinç TT; Süner G; Emir A; Yanat AN
    Eklem Hastalik Cerrahisi; 2009; 20(2):102-6. PubMed ID: 19619114
    [TBL] [Abstract][Full Text] [Related]  

  • 22. The mechanical interaction between three geometric types of nylon core suture and a running epitenon suture in repair of porcine flexor tendons.
    de Wit T; Walbeehm ET; Hovius SE; McGrouther DA
    J Hand Surg Eur Vol; 2013 Sep; 38(7):788-94. PubMed ID: 23649010
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Causes of Flexor Tendon Repair Failures in Two Common Repair Techniques: A Cadaver Study.
    Mistry R; McCleave MJ; Codrington J
    J Hand Surg Asian Pac Vol; 2016 Oct; 21(3):333-8. PubMed ID: 27595950
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Flexor tendon repair with barbed suture: an experimental study.
    Sato M; Matsumura H; Gondo M; Shimada K; Watanabe K
    Eur J Orthop Surg Traumatol; 2014 Dec; 24(8):1421-4. PubMed ID: 24121796
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Biomechanical evaluation of flexor tendon repair techniques.
    Tang JB; Wang B; Chen F; Pan CZ; Xie RG
    Clin Orthop Relat Res; 2001 May; (386):252-9. PubMed ID: 11347844
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Effects of direction of tendon lacerations on strength of tendon repairs.
    Tan J; Wang B; Xu Y; Tang JB
    J Hand Surg Am; 2003 Mar; 28(2):237-42. PubMed ID: 12671854
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Flexor tendon repair with a knotless, bidirectional barbed suture: an in vivo biomechanical analysis.
    Maddox GE; Ludwig J; Craig ER; Woods D; Joiner A; Chaudhari N; Killingsworth C; Siegal GP; Eberhardt A; Ponce B
    J Hand Surg Am; 2015 May; 40(5):963-8. PubMed ID: 25747739
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Comparison of Flexor Tendon Suture Techniques Including 1 Using 10 Strands.
    Lee HI; Lee JS; Kim TH; Chang SH; Park MJ; Lee GJ
    J Hand Surg Am; 2015 Jul; 40(7):1369-76. PubMed ID: 26050206
    [TBL] [Abstract][Full Text] [Related]  

  • 29. An Exploratory Study Using Semi-Tabular Plate in Zone II Flexor Tendon Repair.
    Wong YR; Jais ISM; Chang MK; Lim BH; Tay SC
    J Hand Surg Asian Pac Vol; 2018 Dec; 23(4):547-553. PubMed ID: 30428798
    [TBL] [Abstract][Full Text] [Related]  

  • 30. [Effectiveness of microsurgical repair of flexor tendon rupture by non-knot Kessler suture method in anastomotic stoma].
    Tang Y; Li Y
    Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi; 2011 Oct; 25(10):1210-3. PubMed ID: 22069976
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Biomechanical Properties of a Novel Mesh Suture in a Cadaveric Flexor Tendon Repair Model.
    Wallace SJ; Mioton LM; Havey RM; Muriuki MG; Ko JH
    J Hand Surg Am; 2019 Mar; 44(3):208-215. PubMed ID: 30660397
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Increased suture embedment in tendons: an effective method to improve repair strength.
    Wang B; Tang JB
    J Hand Surg Br; 2002 Aug; 27(4):333-6. PubMed ID: 12162971
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Comparison of Barbed Sutures in Porcine Flexor Tenorrhaphy.
    Sull A; Inceoglu S; August A; Gregorius S; Wongworawat MD
    Hand (N Y); 2016 Dec; 11(4):475-478. PubMed ID: 28149217
    [No Abstract]   [Full Text] [Related]  

  • 34. Dynamic Tendon Grip (DTG™) novel knot array compared to traditional sutures for zone two flexor tendon injury - a biomechanical feasibility study.
    Kadar A; Fainzack A; Vigler M
    BMC Musculoskelet Disord; 2022 Apr; 23(1):320. PubMed ID: 35379221
    [TBL] [Abstract][Full Text] [Related]  

  • 35. The Effects of the TSOL Knot on the Repair Strength and Gliding Resistance Following Flexor Tendon Repair.
    Berry CE; Mazzucchelli L; Reisdorf RL; Moran SL; Zhao C
    J Bone Joint Surg Am; 2022 Nov; 104(22):2000-2007. PubMed ID: 36000752
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Comparison of 1- and 2-knot, 4-strand, double-modified kessler tendon repairs in a porcine model.
    Rees L; Matthews A; Masouros SD; Bull AM; Haywood R
    J Hand Surg Am; 2009 Apr; 34(4):705-9. PubMed ID: 19345874
    [TBL] [Abstract][Full Text] [Related]  

  • 37. The effect of epitendinous suture technique on gliding resistance during cyclic motion after flexor tendon repair: a cadaveric study.
    Moriya T; Zhao C; An KN; Amadio PC
    J Hand Surg Am; 2010 Apr; 35(4):552-8. PubMed ID: 20189323
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Influence of core suture geometry on tendon deformation and gap formation in porcine flexor tendons.
    Walbeehm ET; De Wit T; Hovius SE; McGrouther DA
    J Hand Surg Eur Vol; 2009 Apr; 34(2):190-5. PubMed ID: 19282412
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Flexor tendon repair: a comparative study between a knotless barbed suture repair and a traditional four-strand monofilament suture repair.
    Joyce CW; Whately KE; Chan JC; Murphy M; O'Brien FJ; Carroll SM
    J Hand Surg Eur Vol; 2014 Jan; 39(1):40-5. PubMed ID: 23695149
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Effect of the Optimal Asymmetry on the Strength of Six-Strand Tendon Repair: An Ex Vivo Biomechanical Study.
    Kozono N; Okada T; Takeuchi N; Shimoto T; Higaki H; Nakashima Y
    J Hand Surg Am; 2017 Apr; 42(4):250-256. PubMed ID: 28242243
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 6.