These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

128 related articles for article (PubMed ID: 38309739)

  • 21. Preoperative Risk Factors Associated With Poor Outcomes of Revision Surgery for "Pseudotumors" in Patients With Metal-on-Metal Hip Arthroplasty.
    Liow MH; Dimitriou D; Tsai TY; Kwon YM
    J Arthroplasty; 2016 Dec; 31(12):2835-2842. PubMed ID: 27387480
    [TBL] [Abstract][Full Text] [Related]  

  • 22. [Metal on metal bearing surfaces in total hip arthroplasty: a survey of material incidents].
    Passuti N; Terver S
    Rev Chir Orthop Reparatrice Appar Mot; 2007 May; 93(3):288-312. PubMed ID: 17534213
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Early Outcomes of Revision Surgery for Taper Corrosion of Dual Taper Total Hip Arthroplasty in 187 Patients.
    Dimitriou D; Liow MH; Tsai TY; Leone WA; Li G; Kwon YM
    J Arthroplasty; 2016 Jul; 31(7):1549-54. PubMed ID: 26895822
    [TBL] [Abstract][Full Text] [Related]  

  • 24. What Is the Frequency of Fracture of Ceramic Components in THA? Results from the Norwegian Arthroplasty Register from 1997 to 2017.
    Hallan G; Fenstad AM; Furnes O
    Clin Orthop Relat Res; 2020 Jun; 478(6):1254-1261. PubMed ID: 32348085
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Sensitivity and Specificity of Metal Ion Level in Predicting Adverse Local Tissue Reactions Due to Head-Neck Taper Corrosion in Primary Metal-on-Polyethylene Total Hip Arthroplasty.
    Kwon YM; MacAuliffe J; Arauz PG; Peng Y
    J Arthroplasty; 2018 Sep; 33(9):3025-3029. PubMed ID: 29748069
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Bearing Change to Metal-On-Polyethylene for Ceramic Bearing Fracture in Total Hip Arthroplasty; Does It Work?
    Lee SJ; Kwak HS; Yoo JJ; Kim HJ
    J Arthroplasty; 2016 Jan; 31(1):204-8. PubMed ID: 26404851
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Risk Factors Associated With Early Complications of Revision Surgery for Head-Neck Taper Corrosion in Metal-on-Polyethylene Total Hip Arthroplasty.
    Kwon YM; Rossi D; MacAuliffe J; Peng Y; Arauz P
    J Arthroplasty; 2018 Oct; 33(10):3231-3237. PubMed ID: 29958755
    [TBL] [Abstract][Full Text] [Related]  

  • 28. [Our Experience with ICON Hip Resurfacing System].
    Trč T; Šťastný E; Kopečný Z; Kos P; Přidal J; Havlas V
    Acta Chir Orthop Traumatol Cech; 2022; 89(5):323-331. PubMed ID: 36322031
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Ceramic-on-Ceramic or Metal-on-Polyethylene: The Bearing of Choice after Ceramic Component Fracture in Total Hip Arthroplasty along with Concise Follow-Up of the Previous Cohort.
    Kim HS; Lee HJ; Lee SJ; Yoo JJ
    Orthop Surg; 2023 Nov; 15(11):2864-2871. PubMed ID: 37749775
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Course of Metal Ions after a Revision of Malfunctioning Metal-on-Metal Total Hip Prostheses.
    Nicolli A; Bortoletti I; Maso S; Trevisan A
    Medicina (Kaunas); 2021 Jan; 57(2):. PubMed ID: 33525335
    [TBL] [Abstract][Full Text] [Related]  

  • 31. What Are Normal Metal Ion Levels After Total Hip Arthroplasty? A Serologic Analysis of Four Bearing Surfaces.
    Barlow BT; Ortiz PA; Boles JW; Lee YY; Padgett DE; Westrich GH
    J Arthroplasty; 2017 May; 32(5):1535-1542. PubMed ID: 28190644
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Revision of ceramic fracture with ceramic-on-polyethylene in total hip arthroplasty: Medium-term results.
    Zagra L; Bianchi L; Giacometti Ceroni R
    Injury; 2016 Oct; 47 Suppl 4():S116-S120. PubMed ID: 27507545
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Revision total hip arthroplasty due to pain from hypersensitivity to cobalt-chromium in total hip arthroplasty.
    Kosukegawa I; Nagoya S; Kaya M; Sasaki K; Sasaki M; Yamashita T
    J Arthroplasty; 2011 Sep; 26(6):978.e1-3. PubMed ID: 21130600
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Neuropsychiatric symptoms following metal-on-metal implant failure with cobalt and chromium toxicity.
    Green B; Griffiths E; Almond S
    BMC Psychiatry; 2017 Jan; 17(1):33. PubMed ID: 28114963
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Do cobalt and chromium blood metal ion levels normalize after revision of failed metal-on-metal total hip replacements?
    Jungwirth-Weinberger A; Hanreich C; Kasparek MF; Renner L; Waldstein W; Boettner F
    Arch Orthop Trauma Surg; 2023 Mar; 143(3):1217-1221. PubMed ID: 34724103
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Adverse Local Tissue Reactions are Common in Asymptomatic Individuals After Hip Resurfacing Arthroplasty: Interim Report from a Prospective Longitudinal Study.
    Koff MF; Gao MA; Neri JP; Chiu YF; Lin BQ; Burge AJ; Su E; Padgett DE; Potter HG
    Clin Orthop Relat Res; 2021 Dec; 479(12):2633-2650. PubMed ID: 34232144
    [TBL] [Abstract][Full Text] [Related]  

  • 37. A Comparison of Blood Metal Ions in Total Hip Arthroplasty Using Metal and Ceramic Heads.
    White PB; Meftah M; Ranawat AS; Ranawat CS
    J Arthroplasty; 2016 Oct; 31(10):2215-20. PubMed ID: 27108055
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Hard-on-Hard Bearings Are Associated With Increased Noise Generation in Young Patients Undergoing Hip Arthroplasty.
    Nam D; Barrack T; Johnson SR; Nunley RM; Barrack RL
    Clin Orthop Relat Res; 2016 Oct; 474(10):2115-22. PubMed ID: 26911973
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Acetabular cup malalignment after total hip resurfacing arthroplasty: a case for elective revision?
    Mai MC; Milbrandt JC; Hulsen J; Allan DG
    Orthopedics; 2009 Nov; 32(11):853. PubMed ID: 19902880
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Stainless Steel Femoral Heads Reduce Rate of Revision When Compared to Ion-Implanted Chromium-Cobalt Heads With a Single Cemented Femoral Design: An Analysis of 40,468 Total Hip Replacements From the Australian Orthopedic Association National Joint Replacement Registry.
    Babazadeh S; de Steiger RN; Peng Y; van Bavel D
    J Arthroplasty; 2021 Dec; 36(12):3945-3949. PubMed ID: 34521567
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 7.