BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

124 related articles for article (PubMed ID: 38323783)

  • 1. Consistency of Monoenergetic Attenuation Measurements for a Clinical Dual-Source Photon-Counting Detector CT System Across Scanning Paradigms: A Phantom Study.
    Yang Y; Qin L; Lin H; Xu Z; Schmidt B; Leidecker C; Yang W; Wen N; Yan F
    AJR Am J Roentgenol; 2024 May; 222(5):e2330631. PubMed ID: 38323783
    [No Abstract]   [Full Text] [Related]  

  • 2. Metal Artifact Reduction in Photon-Counting Detector CT: Quantitative Evaluation of Artifact Reduction Techniques.
    Skornitzke S; Mergen V; Biederer J; Alkadhi H; Do TD; Stiller W; Frauenfelder T; Kauczor HU; Euler A
    Invest Radiol; 2024 Jun; 59(6):442-449. PubMed ID: 37812482
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Epicardial Adipose Tissue Attenuation and Fat Attenuation Index: Phantom Study and In Vivo Measurements With Photon-Counting Detector CT.
    Mergen V; Ried E; Allmendinger T; Sartoretti T; Higashigaito K; Manka R; Euler A; Alkadhi H; Eberhard M
    AJR Am J Roentgenol; 2022 May; 218(5):822-829. PubMed ID: 34877869
    [No Abstract]   [Full Text] [Related]  

  • 4. Characterization of single- and multi-energy CT performance of an oral dark borosilicate contrast media using a clinical photon-counting-detector CT platform.
    Ren L; Sun Y; Yeh B; Marsh JF; Winfree TN; Burke KA; Rajendran K; McCollough CH; Mileto A; Fletcher JG; Leng S
    Med Phys; 2023 Nov; 50(11):6779-6788. PubMed ID: 37669507
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Pseudoenhancement in Cystic Renal Lesions - Impact of Virtual Monoenergetic Images of Photon-Counting Detector CT on Lesion Classification.
    Schade KA; Mergen V; Sartoretti T; Alkadhi H; Euler A
    Acad Radiol; 2023 Sep; 30 Suppl 1():S305-S313. PubMed ID: 37150736
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Quantitative performance of photon-counting CT at low dose: Virtual monochromatic imaging and iodine quantification.
    Vrbaski S; Bache S; Rajagopal J; Samei E
    Med Phys; 2023 Sep; 50(9):5421-5433. PubMed ID: 37415402
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Task-based automatic keV selection: leveraging routine virtual monoenergetic imaging for dose reduction on clinical photon-counting detector CT
    Rajendran K; Bruesewitz M; Swicklik J; Ferrero A; Thorne J; Yu L; McCollough C; Leng S
    Phys Med Biol; 2024 May; 69(11):. PubMed ID: 38648795
    [No Abstract]   [Full Text] [Related]  

  • 8. Impact of Contrast Enhancement and Virtual Monoenergetic Image Energy Levels on Emphysema Quantification: Experience With Photon-Counting Detector Computed Tomography.
    Jungblut L; Kronenberg D; Mergen V; Higashigaito K; Schmidt B; Euler A; Alkadhi H; Frauenfelder T; Martini K
    Invest Radiol; 2022 Jun; 57(6):359-365. PubMed ID: 35066533
    [TBL] [Abstract][Full Text] [Related]  

  • 9. High-Pitch Photon-Counting Detector Computed Tomography Angiography of the Aorta: Intraindividual Comparison to Energy-Integrating Detector Computed Tomography at Equal Radiation Dose.
    Euler A; Higashigaito K; Mergen V; Sartoretti T; Zanini B; Schmidt B; Flohr TG; Ulzheimer S; Eberhard M; Alkadhi H
    Invest Radiol; 2022 Feb; 57(2):115-121. PubMed ID: 34352805
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Impact of virtual monoenergetic levels on coronary plaque volume components using photon-counting computed tomography.
    Vattay B; Szilveszter B; Boussoussou M; Vecsey-Nagy M; Lin A; Konkoly G; Kubovje A; Schwarz F; Merkely B; Maurovich-Horvat P; Williams MC; Dey D; Kolossváry M
    Eur Radiol; 2023 Dec; 33(12):8528-8539. PubMed ID: 37488295
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Combining virtual monoenergetic imaging and iterative metal artifact reduction in first-generation photon-counting computed tomography of patients with dental implants.
    Patzer TS; Kunz AS; Huflage H; Gruschwitz P; Pannenbecker P; Afat S; Herrmann J; Petritsch B; Bley TA; Grunz JP
    Eur Radiol; 2023 Nov; 33(11):7818-7829. PubMed ID: 37284870
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Photon-counting detector coronary CT angiography: impact of virtual monoenergetic imaging and iterative reconstruction on image quality.
    Sartoretti T; McDermott M; Mergen V; Euler A; Schmidt B; Jost G; Wildberger JE; Alkadhi H
    Br J Radiol; 2023 Mar; 96(1143):20220466. PubMed ID: 36633005
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Evaluation of Virtual Monoenergetic Images on Pulmonary Vasculature Using the Dual-Layer Detector-Based Spectral Computed Tomography.
    Ghandour A; Sher A; Rassouli N; Dhanantwari A; Rajiah P
    J Comput Assist Tomogr; 2018; 42(6):858-865. PubMed ID: 29659426
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Photon-Counting Computed Tomography for Vascular Imaging of the Head and Neck: First In Vivo Human Results.
    Symons R; Reich DS; Bagheri M; Cork TE; Krauss B; Ulzheimer S; Kappler S; Bluemke DA; Pourmorteza A
    Invest Radiol; 2018 Mar; 53(3):135-142. PubMed ID: 28926370
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Realistic Kidney Tissue Surrogates for Multienergy Computed Tomography-Feasibility and Estimation of Energy-Dependent Attenuation Thresholds for Renal Lesion Enhancement in Low-kV and Virtual Monoenergetic Imaging.
    Euler A; Zadory M; Breiding PS; Sartoretti T; Ghafoor S; Froehlich JM; Donati OF
    Invest Radiol; 2021 Dec; 56(12):791-798. PubMed ID: 33899757
    [TBL] [Abstract][Full Text] [Related]  

  • 16. CT-based thermometry with virtual monoenergetic images by dual-energy of fat, muscle and bone using FBP, iterative and deep learning-based reconstruction.
    Heinrich A; Schenkl S; Buckreus D; Güttler FV; Teichgräber UK
    Eur Radiol; 2022 Jan; 32(1):424-431. PubMed ID: 34327575
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Improved Opacification of a Suboptimally Enhanced Pulmonary Artery in Chest CT: Experience Using a Dual-Layer Detector Spectral CT.
    Bae K; Jeon KN; Cho SB; Park SE; Moon JI; Baek HJ; Choi BH
    AJR Am J Roentgenol; 2018 Apr; 210(4):734-741. PubMed ID: 29446668
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Photon-Counting CT: High-Resolution Imaging of Coronary Stents.
    Mannil M; Hickethier T; von Spiczak J; Baer M; Henning A; Hertel M; Schmidt B; Flohr T; Maintz D; Alkadhi H
    Invest Radiol; 2018 Mar; 53(3):143-149. PubMed ID: 28945655
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Contrast-Enhanced Abdominal CT with Clinical Photon-Counting Detector CT: Assessment of Image Quality and Comparison with Energy-Integrating Detector CT.
    Higashigaito K; Euler A; Eberhard M; Flohr TG; Schmidt B; Alkadhi H
    Acad Radiol; 2022 May; 29(5):689-697. PubMed ID: 34389259
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Establishing a quality assurance program for photon counting detector (PCD) CT: Tips and caveats.
    Ahmed Z; Ferrero A; Ren L; Vrieze TJ; Rajendran K; Favazza CP; Yu L; Bruesewitz MR; McCollough CH; Leng S
    J Appl Clin Med Phys; 2023 Jul; 24(7):e14074. PubMed ID: 37335819
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.