These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

136 related articles for article (PubMed ID: 38329841)

  • 21. Crestal Bone Loss Around Adjacent Dental Implants Restored with Splinted and Nonsplinted Fixed Restorations: A Systematic Literature Review.
    Al Amri MD; Kellesarian SV
    J Prosthodont; 2017 Aug; 26(6):495-501. PubMed ID: 27996179
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Clinical evaluation of marginal bone level change of multiple adjacent implants restored with splinted and nonsplinted restorations: a 5-year prospective study.
    Vigolo P; Zaccaria M
    Int J Oral Maxillofac Implants; 2010; 25(6):1189-94. PubMed ID: 21197497
    [TBL] [Abstract][Full Text] [Related]  

  • 23. An assessment of crown-to-root ratios with short sintered porous-surfaced implants supporting prostheses in partially edentulous patients.
    Rokni S; Todescan R; Watson P; Pharoah M; Adegbembo AO; Deporter D
    Int J Oral Maxillofac Implants; 2005; 20(1):69-76. PubMed ID: 15747676
    [TBL] [Abstract][Full Text] [Related]  

  • 24. LIMITED EVIDENCE SUGGESTS SURVIVAL OF NON-SPLINTED SHORT IMPLANTS (≤8.5 MM) IS COMPARABLE TO THAT OF SPLINTED IMPLANTS.
    Radi IA; Ismail SM
    J Evid Based Dent Pract; 2023 Jun; 23(2):101840. PubMed ID: 37201981
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Evaluation of stress induced by implant type, number of splinted teeth, and variations in periodontal support in tooth-implant-supported fixed partial dentures: a non-linear finite element analysis.
    Lin CL; Wang JC; Chang SH; Chen ST
    J Periodontol; 2010 Jan; 81(1):121-30. PubMed ID: 20059424
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Effect of Splinting of Tilted External Hexagon Implants on 3-Unit Implant-Supported Prostheses in the Posterior Maxilla: A 3D Finite Element Analysis.
    de Faria Almeida DA; Verri FR; Lemos CAA; de Souza Batista VE; Santiago Júnior JF; Rosa CDDRD; Noritomi PY; Pellizzer EP
    J Prosthodont; 2022 Oct; 31(8):697-704. PubMed ID: 34859540
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Finite element analysis of implant-supported prosthesis with pontic and cantilever in the posterior maxilla.
    de Souza Batista VE; Verri FR; Almeida DA; Santiago Junior JF; Lemos CA; Pellizzer EP
    Comput Methods Biomech Biomed Engin; 2017 May; 20(6):663-670. PubMed ID: 28349769
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Splinting or Nonsplinting Adjacent Implants? A Retrospective Study Up to 15 Years: Part II-Success and Survival Rate Analysis.
    Yi Y; Heo SJ; Koak JY; Kim SK; Koo KT
    Int J Oral Maxillofac Implants; 2023 May, Jun; 38(3):443-450b. PubMed ID: 37279229
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Maxillary Implant-Supported Fixed Prosthesis: A Survey of Reviews and Key Variables for Treatment Planning.
    Gallucci GO; Avrampou M; Taylor JC; Elpers J; Thalji G; Cooper LF
    Int J Oral Maxillofac Implants; 2016; 31 Suppl():s192-7. PubMed ID: 27228251
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Evaluation of accuracy of multiple dental implant impressions using various splinting materials.
    Hariharan R; Shankar C; Rajan M; Baig MR; Azhagarasan NS
    Int J Oral Maxillofac Implants; 2010; 25(1):38-44. PubMed ID: 20209185
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Displacement of screw-retained splinted and nonsplinted restorations into implants with conical internal connections.
    Yilmaz B; Seidt JD; Clelland NL
    Int J Oral Maxillofac Implants; 2014; 29(6):1289-92. PubMed ID: 25397792
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Long-Term Effectiveness of Extra-Short (≤ 6 mm) Dental Implants: A Systematic Review.
    Ravidà A; Barootchi S; Askar H; Suárez-López Del Amo F; Tavelli L; Wang HL
    Int J Oral Maxillofac Implants; 2019; 34(1):68-84. PubMed ID: 30695086
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Biomechanical interactions in tooth-implant-supported fixed partial dentures with variations in the number of splinted teeth and connector type: a finite element analysis.
    Lin CL; Wang JC; Chang WJ
    Clin Oral Implants Res; 2008 Jan; 19(1):107-17. PubMed ID: 17944965
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Stress and Strain Distribution Patterns in Bone around Splinted Standard and Short Implants Placed at the Crestal Level and Subcrestally using Three- Dimensional Finite Element Analysis.
    Amid R; Rasoolzadeh RA; Motlagh AM; Dehnavi F; Kadkhodazadeh M
    J Long Term Eff Med Implants; 2017; 27(1):1-11. PubMed ID: 29604944
    [TBL] [Abstract][Full Text] [Related]  

  • 35. A retrospective evaluation of the survival rates of splinted and non-splinted short dental implants in posterior partially edentulous jaws.
    Mendonça JA; Francischone CE; Senna PM; Matos de Oliveira AE; Sotto-Maior BS
    J Periodontol; 2014 Jun; 85(6):787-94. PubMed ID: 24171498
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Evaluation of the accuracy of implant-level impression techniques for internal-connection implant prostheses in parallel and divergent models.
    Choi JH; Lim YJ; Yim SH; Kim CW
    Int J Oral Maxillofac Implants; 2007; 22(5):761-8. PubMed ID: 17974110
    [TBL] [Abstract][Full Text] [Related]  

  • 37. The significance of vertical platform discrepancies and splinting on marginal bone levels for adjacent dental implants.
    Lin GH; Tran C; Brzyska K; Kan JY; Wang HL; Curtis DA; Kao RT
    Clin Implant Dent Relat Res; 2023 Apr; 25(2):321-329. PubMed ID: 36593583
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Immediate flapless full-arch rehabilitation of edentulous jaws on 4 or 6 implants according to the prosthetic-driven planning and guided implant surgery: A retrospective study on clinical and radiographic outcomes up to 10 years of follow-up.
    La Monaca G; Pranno N; Annibali S; Di Carlo S; Pompa G; Cristalli MP
    Clin Implant Dent Relat Res; 2022 Dec; 24(6):831-844. PubMed ID: 36197040
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Photoelastic stress analysis of different designs of cement-retained fixed partial dentures on Morse taper oral implants.
    Menani LR; Tiossi R; de Torres ÉM; Ribeiro RF; de Almeida RP
    J Craniofac Surg; 2011 Mar; 22(2):674-8. PubMed ID: 21415635
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Biomechanical finite element analysis of short-implant-supported, 3-unit, fixed CAD/CAM prostheses in the posterior mandible.
    Zupancic Cepic L; Frank M; Reisinger A; Pahr D; Zechner W; Schedle A
    Int J Implant Dent; 2022 Feb; 8(1):8. PubMed ID: 35147791
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 7.