124 related articles for article (PubMed ID: 38329934)
1. Development of a Highly Sensitive, Visual Platform for the Detection of Cadmium in Actual Wastewater Based on Evolved Whole-Cell Biosensors.
Shen L; Chen Y; Hu L; Zhang C; Liu L; Bao L; Ma J; Wang H; Xiao X; Wu L; Chen S
ACS Sens; 2024 Feb; 9(2):654-661. PubMed ID: 38329934
[TBL] [Abstract][Full Text] [Related]
2. Engineering the Ultrasensitive Visual Whole-Cell Biosensors by Evolved MerR and 5' UTR for Detection of Ultratrace Mercury.
Zhu K; Chen D; Cai Y; Zhang T; Ma J; Bao L; Zhao F; Wu L; Chen S
Environ Sci Technol; 2023 Nov; 57(44):16964-16973. PubMed ID: 37863904
[TBL] [Abstract][Full Text] [Related]
3. Construction of cadmium whole-cell biosensors and circuit amplification.
Jia X; Liu T; Ma Y; Wu K
Appl Microbiol Biotechnol; 2021 Jul; 105(13):5689-5699. PubMed ID: 34160647
[TBL] [Abstract][Full Text] [Related]
4. Sensitive and Specific Whole-Cell Biosensor for Arsenic Detection.
Jia X; Bu R; Zhao T; Wu K
Appl Environ Microbiol; 2019 Jun; 85(11):. PubMed ID: 30952659
[TBL] [Abstract][Full Text] [Related]
5. Evolved Biosensor with High Sensitivity and Specificity for Measuring Cadmium in Actual Environmental Samples.
Cai Y; Zhu K; Shen L; Ma J; Bao L; Chen D; Wei L; Wei N; Liu B; Wu Y; Chen S
Environ Sci Technol; 2022 Jul; 56(14):10062-10071. PubMed ID: 35762704
[TBL] [Abstract][Full Text] [Related]
6. Highly Sensitive Whole-Cell Biosensor for Cadmium Detection Based on a Negative Feedback Circuit.
Zhang G; Hu S; Jia X
Front Bioeng Biotechnol; 2021; 9():799781. PubMed ID: 34926437
[TBL] [Abstract][Full Text] [Related]
7. Simultaneous detection of bioavailable arsenic and cadmium in contaminated soils using dual-sensing bioreporters.
Yoon Y; Kim S; Chae Y; Kim SW; Kang Y; An G; Jeong SW; An YJ
Appl Microbiol Biotechnol; 2016 Apr; 100(8):3713-22. PubMed ID: 26852408
[TBL] [Abstract][Full Text] [Related]
8. Modulating the Properties of Metal-Sensing Whole-Cell Bioreporters by Interfering with
Yoon Y; Kang Y; Lee W; Oh KC; Jang G; Kim BG
J Microbiol Biotechnol; 2018 Feb; 28(2):323-329. PubMed ID: 29212299
[TBL] [Abstract][Full Text] [Related]
9. A Novel Whole-Cell Biosensor for Bioavailable Antimonite in Water and Sediments.
Zhang L; Ye L; Jing C
Appl Environ Microbiol; 2023 Jan; 89(1):e0181722. PubMed ID: 36602327
[TBL] [Abstract][Full Text] [Related]
10. Development of a highly specific and sensitive cadmium and lead microbial biosensor using synthetic CadC-T7 genetic circuitry.
Kim HJ; Lim JW; Jeong H; Lee SJ; Lee DW; Kim T; Lee SJ
Biosens Bioelectron; 2016 May; 79():701-8. PubMed ID: 26773374
[TBL] [Abstract][Full Text] [Related]
11. A Recombinase-Based Genetic Circuit for Heavy Metal Monitoring.
Akboğa D; Saltepe B; Bozkurt EU; Şeker UÖŞ
Biosensors (Basel); 2022 Feb; 12(2):. PubMed ID: 35200383
[TBL] [Abstract][Full Text] [Related]
12. Solid phase biosensors for arsenic or cadmium composed of A trans factor and cis element complex.
Siddiki MS; Kawakami Y; Ueda S; Maeda I
Sensors (Basel); 2011; 11(11):10063-73. PubMed ID: 22346629
[TBL] [Abstract][Full Text] [Related]
13. Detection of Cadmium in Human Biospecimens by a Cadmium-Selective Whole-Cell Biosensor Based on Deoxyviolacein.
Zhang J; Guo Y; Lin YR; Ma BC; Ge XR; Zhang WQ; Zhang NX; Yang SM; Hui CY
ACS Biomater Sci Eng; 2024 Jun; 10(6):4046-4058. PubMed ID: 38722544
[TBL] [Abstract][Full Text] [Related]
14. Smartphone-Based Whole-Cell Biosensor Platform Utilizing an Immobilization Approach on a Filter Membrane Disk for the Monitoring of Water Toxicants.
Ma J; Harpaz D; Liu Y; Eltzov E
Sensors (Basel); 2020 Sep; 20(19):. PubMed ID: 32992697
[TBL] [Abstract][Full Text] [Related]
15. Functional GFP-metallothionein fusion protein from Tetrahymena thermophila: a potential whole-cell biosensor for monitoring heavy metal pollution and a cell model to study metallothionein overproduction effects.
Amaro F; Turkewitz AP; Martín-González A; Gutiérrez JC
Biometals; 2014 Feb; 27(1):195-205. PubMed ID: 24430977
[TBL] [Abstract][Full Text] [Related]
16. Detection of Bioavailable Cadmium by Double-Color Fluorescence Based on a Dual-Sensing Bioreporter System.
Hui CY; Guo Y; Wu J; Liu L; Yang XQ; Guo X; Xie Y; Yi J
Front Microbiol; 2021; 12():696195. PubMed ID: 34603225
[TBL] [Abstract][Full Text] [Related]
17. Sensitive and Specific Cadmium Biosensor Developed by Reconfiguring Metal Transport and Leveraging Natural Gene Repositories.
He MY; Lin YJ; Kao YL; Kuo P; Grauffel C; Lim C; Cheng YS; Chou HD
ACS Sens; 2021 Mar; 6(3):995-1002. PubMed ID: 33444502
[TBL] [Abstract][Full Text] [Related]
18. Use of whole-cell bioreporters to assess bioavailability of contaminants in aquatic systems.
Zhu Y; Elcin E; Jiang M; Li B; Wang H; Zhang X; Wang Z
Front Chem; 2022; 10():1018124. PubMed ID: 36247665
[TBL] [Abstract][Full Text] [Related]
19. High-throughput visualization mutation screening technology to enhance the specificity of CadR based whole-cell cadmium biosensor.
Guo M; Chen S; Su H; Chen X; Liu H; Sun B
Biosens Bioelectron; 2024 Jul; 256():116266. PubMed ID: 38636122
[TBL] [Abstract][Full Text] [Related]
20. Two plant-hosted whole-cell bacterial biosensors for detection of bioavailable Cr(VI).
Francisco R; Branco R; Schwab S; Baldani I; Morais PV
World J Microbiol Biotechnol; 2019 Aug; 35(8):129. PubMed ID: 31376017
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]