BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

120 related articles for article (PubMed ID: 38335742)

  • 21. Monte Carlo calculation of detector perturbation and quality correction factors in a 1.5 T magnetic resonance guided radiation therapy small photon beams.
    Cervantes Y; Duchaine J; Billas I; Duane S; Bouchard H
    Phys Med Biol; 2021 Nov; 66(22):. PubMed ID: 34700311
    [No Abstract]   [Full Text] [Related]  

  • 22. MR compatible detectors assessment for a 0.35 T MR-linac commissioning.
    Chea M; Croisé M; Huet C; Bassinet C; Benadjaoud MA; Jenny C
    Radiat Oncol; 2024 Mar; 19(1):40. PubMed ID: 38509543
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Proton dosimetry in a magnetic field: Measurement and calculation of magnetic field correction factors for a plane-parallel ionization chamber.
    Gebauer B; Baumann KS; Fuchs H; Georg D; Oborn BM; Looe HK; Lühr A
    Med Phys; 2024 Mar; 51(3):2293-2305. PubMed ID: 37898105
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Determination of the KQclinfclin,Qmsr fmsr correction factors for detectors used with an 800 MU/min CyberKnife(®) system equipped with fixed collimators and a study of detector response to small photon beams using a Monte Carlo method.
    Moignier C; Huet C; Makovicka L
    Med Phys; 2014 Jul; 41(7):071702. PubMed ID: 24989371
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Water calorimetry in MR-linac: Direct measurement of absorbed dose and determination of chamber
    D'Souza M; Nusrat H; Iakovenko V; Keller B; Sahgal A; Renaud J; Sarfehnia A
    Med Phys; 2020 Dec; 47(12):6458-6469. PubMed ID: 32970325
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Absolute dosimetry of a 1.5 T MR-guided accelerator-based high-energy photon beam in water and solid phantoms using Aerrow.
    Renaud J; Sarfehnia A; Bancheri J; Seuntjens J
    Med Phys; 2020 Mar; 47(3):1291-1304. PubMed ID: 31834640
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Monte Carlo calculation of perturbation correction factors for air-filled ionization chambers in clinical proton beams using TOPAS/GEANT.
    Baumann KS; Kaupa S; Bach C; Engenhart-Cabillic R; Zink K
    Z Med Phys; 2021 May; 31(2):175-191. PubMed ID: 33775521
    [TBL] [Abstract][Full Text] [Related]  

  • 28. ACPSEM position paper: dosimetry for magnetic resonance imaging linear accelerators.
    Begg J; Jelen U; Moutrie Z; Oliver C; Holloway L; Brown R;
    Phys Eng Sci Med; 2023 Mar; 46(1):1-17. PubMed ID: 36806156
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Consequences of air around an ionization chamber: Are existing solid phantoms suitable for reference dosimetry on an MR-linac?
    Hackett SL; van Asselen B; Wolthaus JW; Kok JG; Woodings SJ; Lagendijk JJ; Raaymakers BW
    Med Phys; 2016 Jul; 43(7):3961. PubMed ID: 27370114
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Development and evaluation of a GEANT4-based Monte Carlo Model of a 0.35 T MR-guided radiation therapy (MRgRT) linear accelerator.
    Khan AU; Simiele EA; Lotey R; DeWerd LA; Yadav P
    Med Phys; 2021 Apr; 48(4):1967-1982. PubMed ID: 33555052
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Monte Carlo simulated beam quality and perturbation correction factors for ionization chambers in monoenergetic proton beams.
    Kretschmer J; Dulkys A; Brodbek L; Stelljes TS; Looe HK; Poppe B
    Med Phys; 2020 Nov; 47(11):5890-5905. PubMed ID: 32989779
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Experimental verification of EGSnrc Monte Carlo calculated depth doses within a realistic parallel magnetic field in a polystyrene phantom.
    Ghila A; Steciw S; Fallone BG; Rathee S
    Med Phys; 2017 Sep; 44(9):4804-4815. PubMed ID: 28626920
    [TBL] [Abstract][Full Text] [Related]  

  • 33. [A Survey of Dosimetry in the Magnetic Field of MR-Linacs].
    Sato Y; Abe K; Tsuneda M; Yasui K; Kawachi T; Tohyama N; Mizuno H; Fujita Y
    Igaku Butsuri; 2023; 43(4):107-124. PubMed ID: 38417889
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Output and ([Formula: see text]) correction factors measured and calculated in very small circular fields for microDiamond and EFD-3G detectors.
    Alhakeem E; Zavgorodni S
    Phys Med Biol; 2018 Jul; 63(15):155002. PubMed ID: 29952318
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Monte Carlo simulation for proton dosimetry in magnetic fields: Fano test and magnetic field correction factors
    Marot M; Jäger F; Greilich S; Karger CP; Jäkel O; Burigo LN
    Phys Med Biol; 2023 Aug; 68(17):. PubMed ID: 37567226
    [No Abstract]   [Full Text] [Related]  

  • 36. Technical Note: Consistency of PTW30013 and FC65-G ion chamber magnetic field correction factors.
    Woodings SJ; van Asselen B; van Soest TL; de Prez LA; Lagendijk JJW; Raaymakers BW; Wolthaus JWH
    Med Phys; 2019 Aug; 46(8):3739-3745. PubMed ID: 31131902
    [TBL] [Abstract][Full Text] [Related]  

  • 37. On the implementation of the plan-class specific reference field using multidimensional clustering of plan features and alternative strategies for improved dosimetry in modulated clinical linear accelerator treatments.
    Desai VK; Labby ZE; DeWerd LA; Culberson WS
    Med Phys; 2020 Aug; 47(8):3621-3635. PubMed ID: 32337734
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Small field correction factors determination for several active detectors using a Monte Carlo method in the Elekta Axesse linac equipped with circular cones.
    Girardi A; Fiandra C; Giglioli FR; Gallio E; Ali OH; Ragona R
    Phys Med Biol; 2019 Jun; 64(11):11NT01. PubMed ID: 31051491
    [TBL] [Abstract][Full Text] [Related]  

  • 39. VMAT and IMRT plan-specific correction factors for linac-based ionization chamber dosimetry.
    Desai VK; Labby ZE; Hyun MA; DeWerd LA; Culberson WS
    Med Phys; 2019 Feb; 46(2):913-924. PubMed ID: 30449040
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Relative dosimetry with an MR-linac: Response of ion chambers, diamond, and diode detectors for off-axis, depth dose, and output factor measurements.
    O'Brien DJ; Dolan J; Pencea S; Schupp N; Sawakuchi GO
    Med Phys; 2018 Feb; 45(2):884-897. PubMed ID: 29178457
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 6.