These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

123 related articles for article (PubMed ID: 38339332)

  • 1. In Vivo Microbeam Radiation Therapy at a Conventional Small Animal Irradiator.
    Ahmed M; Bicher S; Combs SE; Lindner R; Raulefs S; Schmid TE; Spasova S; Stolz J; Wilkens JJ; Winter J; Bartzsch S
    Cancers (Basel); 2024 Jan; 16(3):. PubMed ID: 38339332
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Physiologically gated microbeam radiation using a field emission x-ray source array.
    Chtcheprov P; Burk L; Yuan H; Inscoe C; Ger R; Hadsell M; Lu J; Zhang L; Chang S; Zhou O
    Med Phys; 2014 Aug; 41(8):081705. PubMed ID: 25086515
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Treating Brain Tumor with Microbeam Radiation Generated by a Compact Carbon-Nanotube-Based Irradiator: Initial Radiation Efficacy Study.
    Yuan H; Zhang L; Frank JE; Inscoe CR; Burk LM; Hadsell M; Lee YZ; Lu J; Chang S; Zhou O
    Radiat Res; 2015 Sep; 184(3):322-33. PubMed ID: 26305294
    [TBL] [Abstract][Full Text] [Related]  

  • 4. First experimental measurement of the effect of cardio-synchronous brain motion on the dose distribution during microbeam radiation therapy.
    Duncan M; Donzelli M; Pellicioli P; Brauer-Krisch E; Davis JA; Lerch MLF; Rosenfeld AB; Petasecca M
    Med Phys; 2020 Jan; 47(1):213-222. PubMed ID: 31680274
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Technical advances in x-ray microbeam radiation therapy.
    Bartzsch S; Corde S; Crosbie JC; Day L; Donzelli M; Krisch M; Lerch M; Pellicioli P; Smyth LML; Tehei M
    Phys Med Biol; 2020 Jan; 65(2):02TR01. PubMed ID: 31694009
    [TBL] [Abstract][Full Text] [Related]  

  • 6. A high-resolution dose calculation engine for X-ray microbeams radiation therapy.
    Keshmiri S; Brocard S; Serduc R; Adam JF
    Med Phys; 2022 Jun; 49(6):3999-4017. PubMed ID: 35342953
    [TBL] [Abstract][Full Text] [Related]  

  • 7. A proof of principle experiment for microbeam radiation therapy at the Munich compact light source.
    Dombrowsky AC; Burger K; Porth AK; Stein M; Dierolf M; Günther B; Achterhold K; Gleich B; Feuchtinger A; Bartzsch S; Beyreuther E; Combs SE; Pfeiffer F; Wilkens JJ; Schmid TE
    Radiat Environ Biophys; 2020 Mar; 59(1):111-120. PubMed ID: 31655869
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Pilot study for compact microbeam radiation therapy using a carbon nanotube field emission micro-CT scanner.
    Hadsell M; Cao G; Zhang J; Burk L; Schreiber T; Schreiber E; Chang S; Lu J; Zhou O
    Med Phys; 2014 Jun; 41(6):061710. PubMed ID: 24877805
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Effects of pulsed, spatially fractionated, microscopic synchrotron X-ray beams on normal and tumoral brain tissue.
    Bräuer-Krisch E; Serduc R; Siegbahn EA; Le Duc G; Prezado Y; Bravin A; Blattmann H; Laissue JA
    Mutat Res; 2010; 704(1-3):160-6. PubMed ID: 20034592
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Medical physics aspects of the synchrotron radiation therapies: Microbeam radiation therapy (MRT) and synchrotron stereotactic radiotherapy (SSRT).
    Bräuer-Krisch E; Adam JF; Alagoz E; Bartzsch S; Crosbie J; DeWagter C; Dipuglia A; Donzelli M; Doran S; Fournier P; Kalef-Ezra J; Kock A; Lerch M; McErlean C; Oelfke U; Olko P; Petasecca M; Povoli M; Rosenfeld A; Siegbahn EA; Sporea D; Stugu B
    Phys Med; 2015 Sep; 31(6):568-83. PubMed ID: 26043881
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Technical and dosimetric realization of in vivo x-ray microbeam irradiations at the Munich Compact Light Source.
    Burger K; Urban T; Dombrowsky AC; Dierolf M; Günther B; Bartzsch S; Achterhold K; Combs SE; Schmid TE; Wilkens JJ; Pfeiffer F
    Med Phys; 2020 Oct; 47(10):5183-5193. PubMed ID: 32757280
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Film dosimetry studies for patient specific quality assurance in microbeam radiation therapy.
    Ocadiz A; Livingstone J; Donzelli M; Bartzsch S; Nemoz C; Kefs S; Pellicioli P; Giraud JY; Balosso J; Krisch M; Bräuer-Krisch E; Serduc R; Adam JF
    Phys Med; 2019 Sep; 65():227-237. PubMed ID: 31574356
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Dose profiles and x-ray energy optimization for microbeam radiation therapy by high-dose, high resolution dosimetry using Sm-doped fluoroaluminate glass plates and Monte Carlo transport simulation.
    Chicilo F; Hanson AL; Geisler FH; Belev G; Edgar A; Ramaswami KO; Chapman D; Kasap SO
    Phys Med Biol; 2020 Apr; 65(7):075010. PubMed ID: 32242527
    [TBL] [Abstract][Full Text] [Related]  

  • 14. A preclinical microbeam facility with a conventional x-ray tube.
    Bartzsch S; Cummings C; Eismann S; Oelfke U
    Med Phys; 2016 Dec; 43(12):6301. PubMed ID: 27908159
    [TBL] [Abstract][Full Text] [Related]  

  • 15. SYRA3 COST Action--Microbeam radiation therapy: Roots and prospects.
    Bravin A; Olko P; Schültke E; Wilkens JJ
    Phys Med; 2015 Sep; 31(6):561-3. PubMed ID: 26123367
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Influence of polarization and a source model for dose calculation in MRT.
    Bartzsch S; Lerch M; Petasecca M; Bräuer-Krisch E; Oelfke U
    Med Phys; 2014 Apr; 41(4):041703. PubMed ID: 24694123
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Immune-Mediated Effects of Microplanar Radiotherapy with a Small Animal Irradiator.
    Bazyar S; O'Brien ET; Benefield T; Roberts VR; Kumar RJ; Gupta GP; Zhou O; Lee YZ
    Cancers (Basel); 2021 Dec; 14(1):. PubMed ID: 35008319
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Towards high spatial resolution tissue-equivalent dosimetry for microbeam radiation therapy using organic semiconductors.
    Posar JA; Large M; Alnaghy S; Paino JR; Butler DJ; Griffith MJ; Hood S; Lerch MLF; Rosenfeld A; Sellin PJ; Guatelli S; Petasecca M
    J Synchrotron Radiat; 2021 Sep; 28(Pt 5):1444-1454. PubMed ID: 34475292
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Clinical microbeam radiation therapy with a compact source: specifications of the line-focus X-ray tube.
    Winter J; Galek M; Matejcek C; Wilkens JJ; Aulenbacher K; Combs SE; Bartzsch S
    Phys Imaging Radiat Oncol; 2020 Apr; 14():74-81. PubMed ID: 33458318
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Monte Carlo-based treatment planning system calculation engine for microbeam radiation therapy.
    Martinez-Rovira I; Sempau J; Prezado Y
    Med Phys; 2012 May; 39(5):2829-38. PubMed ID: 22559655
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.