These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

162 related articles for article (PubMed ID: 38340201)

  • 41. Robotic-assisted total knee arthroplasty is more advantageous for knees with severe deformity: a randomized controlled trial study design.
    Tian R; Duan X; Kong N; Li X; Wang J; Tian H; Shi Z; Yan S; Lyu J; Wang K; Yang P
    Int J Surg; 2023 Mar; 109(3):287-296. PubMed ID: 36927832
    [TBL] [Abstract][Full Text] [Related]  

  • 42. Accuracy of Computed Tomography-Based Navigation-Assisted Total Knee Arthroplasty: Outlier Analysis.
    Miyasaka T; Kurosaka D; Saito M; Omori T; Ikeda R; Marumo K
    J Arthroplasty; 2017 Jan; 32(1):47-52. PubMed ID: 27369304
    [TBL] [Abstract][Full Text] [Related]  

  • 43. Early Clinical and Radiographic Outcomes of Robot-Assisted Versus Conventional Manual Total Knee Arthroplasty: A Randomized Controlled Study.
    Xu J; Li L; Fu J; Xu C; Ni M; Chai W; Hao L; Zhang G; Chen J
    Orthop Surg; 2022 Sep; 14(9):1972-1980. PubMed ID: 35848154
    [TBL] [Abstract][Full Text] [Related]  

  • 44. High degree of alignment precision associated with total knee arthroplasty performed using a surgical robot or handheld navigation.
    Shen TS; Uppstrom TJ; Walker PJ; Yu JS; Cheng R; Mayman DJ; Jerabek SA; Ast MP
    Knee Surg Sports Traumatol Arthrosc; 2023 Nov; 31(11):4735-4740. PubMed ID: 37382709
    [TBL] [Abstract][Full Text] [Related]  

  • 45. Robot-Assisted Total Knee Arthroplasty Does Not Improve Long-Term Clinical and Radiologic Outcomes.
    Jeon SW; Kim KI; Song SJ
    J Arthroplasty; 2019 Aug; 34(8):1656-1661. PubMed ID: 31036450
    [TBL] [Abstract][Full Text] [Related]  

  • 46. Preliminary outcomes of kinematically aligned robot-assisted total knee arthroplasty with patient-specific cartilage thickness measurement.
    Turan K; Camurcu Y; Kezer M; Uysal Y; Kizilay YO; Temiz A
    J Robot Surg; 2023 Jun; 17(3):979-985. PubMed ID: 36434261
    [TBL] [Abstract][Full Text] [Related]  

  • 47. False malalignment after computer-navigated total knee arthroplasty.
    Tsukeoka T; Tsuneizumi Y
    Knee; 2021 Jun; 30():100-105. PubMed ID: 33887620
    [TBL] [Abstract][Full Text] [Related]  

  • 48. Does Component Alignment Affect Patient Reported Outcomes following Bicruciate Retaining Total Knee Arthroplasty? An In Vivo Three-Dimensional Analysis.
    Peng Y; Arauz P; An S; Limmahakhun S; Klemt C; Kwon YM
    J Knee Surg; 2020 Aug; 33(8):798-803. PubMed ID: 31064018
    [TBL] [Abstract][Full Text] [Related]  

  • 49. Coronal Correction for Severe Deformity Using Robotic-Assisted Total Knee Arthroplasty.
    Marchand RC; Sodhi N; Khlopas A; Sultan AA; Higuera CA; Stearns KL; Mont MA
    J Knee Surg; 2018 Jan; 31(1):2-5. PubMed ID: 29179223
    [TBL] [Abstract][Full Text] [Related]  

  • 50. High accuracy of a new robotically assisted technique for total knee arthroplasty: an in vivo study.
    Rossi SMP; Sangaletti R; Perticarini L; Terragnoli F; Benazzo F
    Knee Surg Sports Traumatol Arthrosc; 2023 Mar; 31(3):1153-1161. PubMed ID: 34981162
    [TBL] [Abstract][Full Text] [Related]  

  • 51. Coronal femoral TKA position significantly influences in vivo patellar loading in unresurfaced patellae after primary total knee arthroplasty.
    Slevin O; Schmid FA; Schiapparelli FF; Rasch H; Amsler F; Hirschmann MT
    Knee Surg Sports Traumatol Arthrosc; 2017 Nov; 25(11):3605-3610. PubMed ID: 28653182
    [TBL] [Abstract][Full Text] [Related]  

  • 52. Radiographic accuracy in TKA with a CT-based patient-specific cutting block technique.
    Koch PP; Müller D; Pisan M; Fucentese SF
    Knee Surg Sports Traumatol Arthrosc; 2013 Oct; 21(10):2200-5. PubMed ID: 23942882
    [TBL] [Abstract][Full Text] [Related]  

  • 53. Patient-specific instrumentation improved three-dimensional accuracy in total knee arthroplasty: a comparative radiographic analysis of 1257 total knee arthroplasties.
    Pauzenberger L; Munz M; Brandl G; Frank JK; Heuberer PR; Laky B; Schwameis E; Anderl W
    J Orthop Surg Res; 2019 Dec; 14(1):437. PubMed ID: 31831022
    [TBL] [Abstract][Full Text] [Related]  

  • 54. Differences in component and limb alignment between computer-assisted and conventional surgery total knee arthroplasty.
    Huang TW; Peng KT; Huang KC; Lee MS; Hsu RW
    Knee Surg Sports Traumatol Arthrosc; 2014 Dec; 22(12):2954-61. PubMed ID: 25331655
    [TBL] [Abstract][Full Text] [Related]  

  • 55. Accuracy of a patient-specific instrumentation for coronal plane alignment of an anatomic alignment total knee arthroplasty system: A radiographic study.
    Müller K; Lerch S; Sauer B; Lerch M
    Technol Health Care; 2022; 30(6):1397-1406. PubMed ID: 35599510
    [TBL] [Abstract][Full Text] [Related]  

  • 56. Two-dimensional planning can result in internal rotation of the femoral component in total knee arthroplasty.
    Okamoto S; Mizu-uchi H; Okazaki K; Hamai S; Tashiro Y; Nakahara H; Iwamoto Y
    Knee Surg Sports Traumatol Arthrosc; 2016 Jan; 24(1):229-35. PubMed ID: 25297705
    [TBL] [Abstract][Full Text] [Related]  

  • 57. Do CAS measurements correlate with EOS 3D alignment measurements in primary TKA?
    Meijer MF; Boerboom AL; Bulstra SK; Reininga IHF; Stevens M
    Knee Surg Sports Traumatol Arthrosc; 2017 Sep; 25(9):2894-2903. PubMed ID: 26913857
    [TBL] [Abstract][Full Text] [Related]  

  • 58. Three-dimensional analysis of accuracy of patient-matched instrumentation in total knee arthroplasty: Evaluation of intraoperative techniques and postoperative alignment.
    Kuwashima U; Mizu-Uchi H; Okazaki K; Hamai S; Akasaki Y; Murakami K; Nakashima Y
    J Orthop Sci; 2017 Nov; 22(6):1077-1083. PubMed ID: 28888738
    [TBL] [Abstract][Full Text] [Related]  

  • 59. [A multicenter randomized controlled trial of domestic robot-assisted and conventional total knee arthroplasty].
    Li Y; Zhang X; Cao L; Sun Y; Ye Y; Xie J; Hu Y; Li Z; Tang B
    Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi; 2023 Nov; 37(11):1326-1334. PubMed ID: 37987040
    [TBL] [Abstract][Full Text] [Related]  

  • 60. Image-free handheld robotic-assisted technology improved the accuracy of implant positioning compared to conventional instrumentation in patients undergoing simultaneous bilateral total knee arthroplasty, without additional benefits in improvement of clinical outcomes.
    Albelooshi A; Hamie M; Bollars P; Althani S; Salameh R; Almasri M; Schotanus MGM; Meshram P
    Knee Surg Sports Traumatol Arthrosc; 2023 Nov; 31(11):4833-4841. PubMed ID: 37558748
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 9.