These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
161 related articles for article (PubMed ID: 38392030)
1. Power-to-Noise Optimization in the Design of Neural Recording Amplifier Based on Current Scaling, Source Degeneration Resistor, and Current Reuse. Wang Z; Wang X; Shu G; Yin M; Huang S; Yin M Biosensors (Basel); 2024 Feb; 14(2):. PubMed ID: 38392030 [TBL] [Abstract][Full Text] [Related]
2. A Low-power and Low-noise Multi-purpose Chopper Amplifier with High CMRR and PSRR. Shad E; Molinas M; Ytterdal T Annu Int Conf IEEE Eng Med Biol Soc; 2020 Jul; 2020():3998-4001. PubMed ID: 33018876 [TBL] [Abstract][Full Text] [Related]
3. An energy-efficient micropower neural recording amplifier. Wattanapanitch W; Fee M; Sarpeshkar R IEEE Trans Biomed Circuits Syst; 2007 Jun; 1(2):136-47. PubMed ID: 23851668 [TBL] [Abstract][Full Text] [Related]
4. A Fully Reconfigurable Low-Noise Biopotential Sensing Amplifier With 1.96 Noise Efficiency Factor. Tzu-Yun Wang ; Min-Rui Lai ; Twigg CM; Sheng-Yu Peng IEEE Trans Biomed Circuits Syst; 2014 Jun; 8(3):411-22. PubMed ID: 24108476 [TBL] [Abstract][Full Text] [Related]
5. A Low-Power Current-Reuse Analog Front-End for High-Density Neural Recording Implants. Rezaei M; Maghsoudloo E; Bories C; De Koninck Y; Gosselin B IEEE Trans Biomed Circuits Syst; 2018 Apr; 12(2):271-280. PubMed ID: 29570055 [TBL] [Abstract][Full Text] [Related]
6. A Power Efficient Low-noise and High Swing CMOS Amplifier for Neural Recording Applications. Naderi K; Shad E; Molinas M; Heidari A Annu Int Conf IEEE Eng Med Biol Soc; 2020 Jul; 2020():4298-4301. PubMed ID: 33018946 [TBL] [Abstract][Full Text] [Related]
7. A compact, low input capacitance neural recording amplifier. Ng KA; Xu YP IEEE Trans Biomed Circuits Syst; 2013 Oct; 7(5):610-20. PubMed ID: 24144666 [TBL] [Abstract][Full Text] [Related]
8. A CMOS power-efficient low-noise current-mode front-end amplifier for neural signal recording. Wu CY; Chen WM; Kuo LT IEEE Trans Biomed Circuits Syst; 2013 Apr; 7(2):107-14. PubMed ID: 23853293 [TBL] [Abstract][Full Text] [Related]
9. A band-tunable, multichannel amplifier for neural recording with AP/LFP separation and dual-threshold adaptive AP detector. Wu JY; Tang KT Annu Int Conf IEEE Eng Med Biol Soc; 2011; 2011():1847-50. PubMed ID: 22254689 [TBL] [Abstract][Full Text] [Related]
10. Design of ultra-low power biopotential amplifiers for biosignal acquisition applications. Zhang F; Holleman J; Otis BP IEEE Trans Biomed Circuits Syst; 2012 Aug; 6(4):344-55. PubMed ID: 23853179 [TBL] [Abstract][Full Text] [Related]
11. A Compact Sub-μW CMOS ECG Amplifier With 57.5-MΩ Z Sawigun C; Thanapitak S IEEE Trans Biomed Circuits Syst; 2021 Jun; 15(3):549-558. PubMed ID: 34081584 [TBL] [Abstract][Full Text] [Related]
12. A Low-Voltage Chopper-Stabilized Amplifier for Fetal ECG Monitoring With a 1.41 Power Efficiency Factor. Song S; Rooijakkers M; Harpe P; Rabotti C; Mischi M; van Roermund AH; Cantatore E IEEE Trans Biomed Circuits Syst; 2015 Apr; 9(2):237-47. PubMed ID: 25879971 [TBL] [Abstract][Full Text] [Related]
13. A Low Noise Amplifier for Neural Spike Recording Interfaces. Ruiz-Amaya J; Rodriguez-Perez A; Delgado-Restituto M Sensors (Basel); 2015 Sep; 15(10):25313-35. PubMed ID: 26437411 [TBL] [Abstract][Full Text] [Related]
14. Energy efficient low-noise neural recording amplifier with enhanced noise efficiency factor. Majidzadeh V; Schmid A; Leblebici Y IEEE Trans Biomed Circuits Syst; 2011 Jun; 5(3):262-71. PubMed ID: 23851477 [TBL] [Abstract][Full Text] [Related]
15. Design of a low-noise low-voltage amplifier for improved neural signal recording. Sharma K; Tripathi RK; Jatana HS; Sharma R Rev Sci Instrum; 2022 Jun; 93(6):064710. PubMed ID: 35777993 [TBL] [Abstract][Full Text] [Related]
16. A 340 nW/Channel 110 dB PSRR Neural Recording Analog Front-End Using Replica-Biasing LNA, Level-Shifter Assisted PGA, and Averaged LFP Servo Loop in 65 nm CMOS. Lyu L; Ye D; Shi CR IEEE Trans Biomed Circuits Syst; 2020 Aug; 14(4):811-824. PubMed ID: 32746334 [TBL] [Abstract][Full Text] [Related]
17. Low-Power Low-Noise Amplifier Using Attenuation-Adaptive Noise Control for Ultrasound Imaging Systems. Jung SJ; Hong SK; Kwon OK IEEE Trans Biomed Circuits Syst; 2017 Feb; 11(1):108-116. PubMed ID: 27337722 [TBL] [Abstract][Full Text] [Related]
18. A 0.5-V multi-channel low-noise readout front-end for portable EEG acquisition. Wen-Yen Huang ; Yu-Wei Cheng ; Kea-Tiong Tang Annu Int Conf IEEE Eng Med Biol Soc; 2015 Aug; 2015():837-40. PubMed ID: 26736392 [TBL] [Abstract][Full Text] [Related]
19. A Low-Noise, Low-Power Amplifier With Current-Reused OTA for ECG Recordings. Zhang J; Zhang H; Sun Q; Zhang R IEEE Trans Biomed Circuits Syst; 2018 Jun; 12(3):700-708. PubMed ID: 29877832 [TBL] [Abstract][Full Text] [Related]
20. A digitally assisted, signal folding neural recording amplifier. Chen Y; Basu A; Liu L; Zou X; Rajkumar R; Dawe GS; Je M IEEE Trans Biomed Circuits Syst; 2014 Aug; 8(4):528-42. PubMed ID: 25073128 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]