These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

124 related articles for article (PubMed ID: 38392122)

  • 1. Design, Characterization, and Preliminary Assessment of a Two-Degree-of-Freedom Powered Ankle-Foot Prosthesis.
    Hsieh TH; Song H; Shu T; Qiao J; Yeon SH; Carney M; Mooney L; Duval JF; Herr H
    Biomimetics (Basel); 2024 Jan; 9(2):. PubMed ID: 38392122
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Does use of a powered ankle-foot prosthesis restore whole-body angular momentum during walking at different speeds?
    D'Andrea S; Wilhelm N; Silverman AK; Grabowski AM
    Clin Orthop Relat Res; 2014 Oct; 472(10):3044-54. PubMed ID: 24781926
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Step-to-step transition work during level and inclined walking using passive and powered ankle-foot prostheses.
    Russell Esposito E; Aldridge Whitehead JM; Wilken JM
    Prosthet Orthot Int; 2016 Jun; 40(3):311-9. PubMed ID: 25628378
    [TBL] [Abstract][Full Text] [Related]  

  • 4. An Ankle-Foot Prosthesis Emulator Capable of Modulating Center of Pressure.
    Chiu VL; Voloshina AS; Collins SH
    IEEE Trans Biomed Eng; 2020 Jan; 67(1):166-176. PubMed ID: 30969914
    [TBL] [Abstract][Full Text] [Related]  

  • 5. An Ankle-Foot Prosthesis for Rock Climbing Augmentation.
    Rogers EA; Carney ME; Yeon SH; Clites TR; Solav D; Herr HM
    IEEE Trans Neural Syst Rehabil Eng; 2021; 29():41-51. PubMed ID: 33095704
    [TBL] [Abstract][Full Text] [Related]  

  • 6. A universal ankle-foot prosthesis emulator for human locomotion experiments.
    Caputo JM; Collins SH
    J Biomech Eng; 2014 Mar; 136(3):035002. PubMed ID: 24337103
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Ankle mechanics during sidestep cutting implicates need for 2-degrees of freedom powered ankle-foot prostheses.
    Ficanha EM; Rastgaar M; Kaufman KR
    J Rehabil Res Dev; 2015; 52(1):97-112. PubMed ID: 26186014
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Powered ankle-foot prosthesis for the improvement of amputee ambulation.
    Au SK; Herr H; Weber J; Martinez-Villalpando EC
    Annu Int Conf IEEE Eng Med Biol Soc; 2007; 2007():3020-6. PubMed ID: 18002631
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Design and Preliminary Evaluation of a Two DOFs Cable-Driven Ankle-Foot Prosthesis with Active Dorsiflexion-Plantarflexion and Inversion-Eversion.
    Ficanha EM; Ribeiro GA; Dallali H; Rastgaar M
    Front Bioeng Biotechnol; 2016; 4():36. PubMed ID: 27200342
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Evaluation of a powered ankle-foot prosthetic system during walking.
    Ferris AE; Aldridge JM; Rábago CA; Wilken JM
    Arch Phys Med Rehabil; 2012 Nov; 93(11):1911-8. PubMed ID: 22732369
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Use of a powered ankle-foot prosthesis reduces the metabolic cost of uphill walking and improves leg work symmetry in people with transtibial amputations.
    Montgomery JR; Grabowski AM
    J R Soc Interface; 2018 Aug; 15(145):. PubMed ID: 30158189
    [TBL] [Abstract][Full Text] [Related]  

  • 12. The influence of a hydraulic prosthetic ankle on residual limb loading during sloped walking.
    Koehler-McNicholas SR; Nickel EA; Medvec J; Barrons K; Mion S; Hansen AH
    PLoS One; 2017; 12(3):e0173423. PubMed ID: 28278172
    [TBL] [Abstract][Full Text] [Related]  

  • 13. A lightweight robotic leg prosthesis replicating the biomechanics of the knee, ankle, and toe joint.
    Tran M; Gabert L; Hood S; Lenzi T
    Sci Robot; 2022 Nov; 7(72):eabo3996. PubMed ID: 36417500
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Segmental contributions to sagittal-plane whole-body angular momentum when using powered compared to passive ankle-foot prostheses on ramps.
    Pickle NT; Silverman AK; Wilken JM; Fey NP
    IEEE Int Conf Rehabil Robot; 2017 Jul; 2017():1609-1614. PubMed ID: 28814050
    [TBL] [Abstract][Full Text] [Related]  

  • 15. A Prototype of a Neural, Powered, Transtibial Prosthesis for the Cat: Benchtop Characterization.
    Park H; Islam MS; Grover MA; Klishko AN; Prilutsky BI; DeWeerth SP
    Front Neurosci; 2018; 12():471. PubMed ID: 30057524
    [TBL] [Abstract][Full Text] [Related]  

  • 16. A controlled clinical trial of a clinically-tuned powered ankle prosthesis in people with transtibial amputation.
    Gardinier ES; Kelly BM; Wensman J; Gates DH
    Clin Rehabil; 2018 Mar; 32(3):319-329. PubMed ID: 28750586
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Whole-body angular momentum during stair walking using passive and powered lower-limb prostheses.
    Pickle NT; Wilken JM; Aldridge JM; Neptune RR; Silverman AK
    J Biomech; 2014 Oct; 47(13):3380-9. PubMed ID: 25213178
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Step-to-Step Ankle Inversion/Eversion Torque Modulation Can Reduce Effort Associated with Balance.
    Kim M; Collins SH
    Front Neurorobot; 2017; 11():62. PubMed ID: 29184493
    [TBL] [Abstract][Full Text] [Related]  

  • 19. The influence of powered prostheses on user perspectives, metabolics, and activity: a randomized crossover trial.
    Kim J; Wensman J; Colabianchi N; Gates DH
    J Neuroeng Rehabil; 2021 Mar; 18(1):49. PubMed ID: 33726802
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Biomechanical Design and Prototyping of a Powered Ankle-Foot Prosthesis.
    Alleva S; Antonelli MG; Zobel PB; Durante F
    Materials (Basel); 2020 Dec; 13(24):. PubMed ID: 33352691
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.