These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

187 related articles for article (PubMed ID: 38399593)

  • 1. Exploration of Point-of-Care Ultrasonography for Silicone Breast Implant Rupture Detection and Classification.
    Kim JH; Kim YG; Song KY; Lim HG; Jeong JP; Sung JY; Lee AS; Park HK
    Medicina (Kaunas); 2024 Feb; 60(2):. PubMed ID: 38399593
    [No Abstract]   [Full Text] [Related]  

  • 2. Multimodality Imaging-based Evaluation of Single-Lumen Silicone Breast Implants for Rupture.
    Seiler SJ; Sharma PB; Hayes JC; Ganti R; Mootz AR; Eads ED; Teotia SS; Evans WP
    Radiographics; 2017; 37(2):366-382. PubMed ID: 28186859
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Untreated silicone breast implant rupture.
    Hölmich LR; Vejborg IM; Conrad C; Sletting S; Høier-Madsen M; Fryzek JP; McLaughlin JK; Kjøller K; Wiik A; Friis S
    Plast Reconstr Surg; 2004 Jul; 114(1):204-14; discussion 215-6. PubMed ID: 15220594
    [TBL] [Abstract][Full Text] [Related]  

  • 4. The diagnosis of breast implant rupture: MRI findings compared with findings at explantation.
    Hölmich LR; Vejborg I; Conrad C; Sletting S; McLaughlin JK
    Eur J Radiol; 2005 Feb; 53(2):213-25. PubMed ID: 15664285
    [TBL] [Abstract][Full Text] [Related]  

  • 5. PIP breast implant removal: a study of 828 cases.
    Oulharj S; Pauchot J; Tropet Y
    J Plast Reconstr Aesthet Surg; 2014 Mar; 67(3):302-7. PubMed ID: 24522122
    [TBL] [Abstract][Full Text] [Related]  

  • 6. [Magnetic tomography in diagnosis of breast implant rupture].
    Kvistad KA; Smenes E; Thuomas KA; Gribbestad IS; Samdal F
    Tidsskr Nor Laegeforen; 1997 Sep; 117(22):3226-8. PubMed ID: 9411862
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Association between Enlarged Axillary Lymph Nodes and Silicone Breast Implant Ruptures seen on Magnetic Resonance Imaging.
    Klang E; Amitai MM; Raskin S; Rozendorn N; Keddel N; Pickovsky J; Sklair-Levy M
    Isr Med Assoc J; 2016 Dec; 18(12):719-724. PubMed ID: 28457073
    [TBL] [Abstract][Full Text] [Related]  

  • 8. The diagnosis of silicone breast implant rupture.
    Gorczyca DP; Gorczyca SM; Gorczyca KL
    Plast Reconstr Surg; 2007 Dec; 120(7 Suppl 1):49S-61S. PubMed ID: 18090814
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Longitudinal Ultrasound Study of Breast Implant Rupture Over a Six-Year Interval.
    Rochira D; Cavalcanti P; Ottaviani A; Tambasco D
    Ann Plast Surg; 2016 Feb; 76(2):150-4. PubMed ID: 25954847
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Silicone breast implant bleed and rupture: clinical diagnosis and predictive value of mammography and ultrasound.
    Beekman WH; Scot MG; Taets van Amerongen AH; Hage JJ; Mulder JW
    Ann Plast Surg; 1996 Apr; 36(4):345-7. PubMed ID: 8779493
    [TBL] [Abstract][Full Text] [Related]  

  • 11. MRI screening for silicone breast implant rupture: accuracy, inter- and intraobserver variability using explantation results as reference standard.
    Maijers MC; Niessen FB; Veldhuizen JF; Ritt MJ; Manoliu RA
    Eur Radiol; 2014 Jun; 24(6):1167-75. PubMed ID: 24599622
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Silent Rupture of Silicone Gel Breast Implants: High-Resolution Ultrasound Scans and Surveys of 584 Women.
    Salzman MJ
    Plast Reconstr Surg; 2022 Jan; 149(1):7-14. PubMed ID: 34936597
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Ability of Dual-Energy CT to Detect Silicone Gel Breast Implant Rupture and Nodal Silicone Spread.
    Glazebrook KN; Doerge S; Leng S; Drees TA; Hunt KN; Zingula SN; Pruthi S; Geske JR; Carter RE; McCollough CH; Fletcher JG
    AJR Am J Roentgenol; 2019 Apr; 212(4):933-942. PubMed ID: 30779664
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Magnetic resonance imaging of breast implants.
    Shah M; Tanna N; Margolies L
    Top Magn Reson Imaging; 2014 Dec; 23(6):345-53. PubMed ID: 25463409
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Decision-analysis methodology in the work-up of women with suspected silicone breast implant rupture.
    Chung KC; Greenfield ML; Walters M
    Plast Reconstr Surg; 1998 Sep; 102(3):689-95. PubMed ID: 9727432
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Rupture of silicone-gel breast implants: causes, sequelae, and diagnosis.
    Brown SL; Silverman BG; Berg WA
    Lancet; 1997 Nov; 350(9090):1531-7. PubMed ID: 9388410
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Detection of Pathologically Proven Silicone Lymphadenopathy: Ultrasonography Versus Magnetic Resonance Imaging.
    Klang E; Yosepovich A; Krosser A; Soffer S; Halshtok Neiman O; Shalmon A; Gotlieb M; Sklair-Levy M
    J Ultrasound Med; 2018 Apr; 37(4):969-975. PubMed ID: 28960388
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Diagnosis of silicone gel breast implant rupture by ultrasonography.
    Chung KC; Wilkins EG; Beil RJ; Helvie MA; Ikeda DM; Oneal RM; Forrest ME; Smith DJ
    Plast Reconstr Surg; 1996 Jan; 97(1):104-9. PubMed ID: 8532766
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Silicone gel breast implant rupture, extracapsular silicone, and health status in a population of women.
    Brown SL; Pennello G; Berg WA; Soo MS; Middleton MS
    J Rheumatol; 2001 May; 28(5):996-1003. PubMed ID: 11361228
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Evaluation of breast silicone implants.
    Brenner RJ
    Magn Reson Imaging Clin N Am; 2013 Aug; 21(3):547-60. PubMed ID: 23928244
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 10.