BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

135 related articles for article (PubMed ID: 38404850)

  • 1. Numerical investigation on the wear characteristics of hip implant under static loading.
    Abu Qudeiri JE; Abdudeen A; Sahadevan MR; Padmanabhan M A
    Heliyon; 2024 Feb; 10(4):e26151. PubMed ID: 38404850
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Development and Validation of a Finite Element Model of Wear in UHMWPE Liner Using Experimental Data From Hip Simulator Studies.
    Kottan N; Gowtham NH; Basu B
    J Biomech Eng; 2022 Mar; 144(3):. PubMed ID: 34505133
    [TBL] [Abstract][Full Text] [Related]  

  • 3. The Effect of Bottom Profile Dimples on the Femoral Head on Wear in Metal-on-Metal Total Hip Arthroplasty.
    Jamari J; Ammarullah MI; Saad APM; Syahrom A; Uddin M; van der Heide E; Basri H
    J Funct Biomater; 2021 Jun; 12(2):. PubMed ID: 34204138
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Enhanced computational prediction of polyethylene wear in hip joints by incorporating cross-shear and contact pressure in additional to load and sliding distance: effect of head diameter.
    Kang L; Galvin AL; Fisher J; Jin Z
    J Biomech; 2009 May; 42(7):912-8. PubMed ID: 19261286
    [TBL] [Abstract][Full Text] [Related]  

  • 5. The computer simulation of wear behavior appearing in total hip prosthesis.
    Wu JS; Hung JP; Shu CS; Chen JH
    Comput Methods Programs Biomed; 2003 Jan; 70(1):81-91. PubMed ID: 12468129
    [TBL] [Abstract][Full Text] [Related]  

  • 6. The Frank Stinchfield Award. 3-Dimensional sliding/contact computational simulation of total hip wear.
    Maxian TA; Brown TD; Pedersen DR; Callaghan JJ
    Clin Orthop Relat Res; 1996 Dec; (333):41-50. PubMed ID: 8981881
    [TBL] [Abstract][Full Text] [Related]  

  • 7. A simple fully integrated contact-coupled wear prediction for ultra-high molecular weight polyethylene hip implants.
    Kang L; Galvin AL; Jin ZM; Fisher J
    Proc Inst Mech Eng H; 2006 Jan; 220(1):33-46. PubMed ID: 16459444
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Analysis of contact pressure in a 3D model of dual-mobility hip joint prosthesis under a gait cycle.
    Tauviqirrahman M; Ammarullah MI; Jamari J; Saputra E; Winarni TI; Kurniawan FD; Shiddiq SA; van der Heide E
    Sci Rep; 2023 Mar; 13(1):3564. PubMed ID: 36864170
    [TBL] [Abstract][Full Text] [Related]  

  • 9. A new formulation for the prediction of polyethylene wear in artificial hip joints.
    Liu F; Galvin A; Jin Z; Fisher J
    Proc Inst Mech Eng H; 2011 Jan; 225(1):16-24. PubMed ID: 21381484
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Design and Performance Evaluation of a Novel Spiral Head-Stem Trunnion for Hip Implants Using Finite Element Analysis.
    Soliman MM; Chowdhury MEH; Islam MT; Musharavati F; Mahmud S; Hafizh M; Ayari MA; Khandakar A; Alam MK; Nezhad EZ
    Materials (Basel); 2023 Feb; 16(4):. PubMed ID: 36837096
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Five-year comparison of wear using oxidised zirconium and cobalt-chrome femoral heads in total hip arthroplasty: a multicentre randomised controlled trial.
    Jassim SS; Patel S; Wardle N; Tahmassebi J; Middleton R; Shardlow DL; Stephen A; Hutchinson J; Haddad FS
    Bone Joint J; 2015 Jul; 97-B(7):883-9. PubMed ID: 26130341
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Finite element wear prediction using adaptive meshing at the modular taper interface of hip implants.
    Bitter T; Khan I; Marriott T; Lovelady E; Verdonschot N; Janssen D
    J Mech Behav Biomed Mater; 2018 Jan; 77():616-623. PubMed ID: 29100204
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Contact stress and sliding wear damage tolerance of hydroxyapatite and carbon nanotube reinforced polyethylene cup liner against zirconia femoral head.
    Nayak C; Singh P; Balani K
    J Mech Behav Biomed Mater; 2022 Dec; 136():105435. PubMed ID: 36244327
    [TBL] [Abstract][Full Text] [Related]  

  • 14. The effect of structural parameters of total hip arthroplasty on polyethylene liner wear behavior: A theoretical model analysis.
    Li G; Peng Y; Zhou C; Jin Z; Bedair H
    J Orthop Res; 2020 Jul; 38(7):1587-1595. PubMed ID: 31876311
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Implant wear mechanisms--basic approach.
    Bhatt H; Goswami T
    Biomed Mater; 2008 Dec; 3(4):042001. PubMed ID: 18824778
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Wear simulation of ultra-high molecular weight polyethylene hip implants by incorporating the effects of cross-shear and contact pressure.
    Kang L; Galvin AL; Brown TD; Fisher J; Jin ZM
    Proc Inst Mech Eng H; 2008 Oct; 222(7):1049-64. PubMed ID: 19024153
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Wear estimation of hip implants with varying chamfer geometry at the trunnion junction: a finite element analysis.
    Gutmann C; Shaikh N; Shenoy BS; Shaymasunder Bhat N; Keni LG; K N C
    Biomed Phys Eng Express; 2023 Mar; 9(3):. PubMed ID: 36716460
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Finite element analysis of hip implant with varying in taper neck lengths under static loading conditions.
    Chethan KN; Shyamasunder Bhat N; Zuber M; Satish Shenoy B
    Comput Methods Programs Biomed; 2021 Sep; 208():106273. PubMed ID: 34284197
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Wear of polyethylene cups in total hip arthroplasty: a parametric mathematical model.
    Pietrabissa R; Raimondi M; Di Martino E
    Med Eng Phys; 1998 Apr; 20(3):199-210. PubMed ID: 9690490
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Wear estimation of trapezoidal and circular shaped hip implants along with varying taper trunnion radiuses using finite element method.
    K N C; Ogulcan G; Bhat N S; Zuber M; Shenoy B S
    Comput Methods Programs Biomed; 2020 Nov; 196():105597. PubMed ID: 32574903
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.