These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

123 related articles for article (PubMed ID: 38416996)

  • 1. Use of Real Time Specimen Radiography to Evaluate the Number of Stereotactic Core Biopsy Specimens Containing Calcifications Required for Diagnosis.
    Kwait DC; Chikarmane SA; Semine-Misbach L; Agoston A; Lester S; Giess CS
    J Breast Imaging; 2022 Dec; 4(6):618-624. PubMed ID: 38416996
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Impact of Non-Calcified Specimen Pathology on the Underestimation of Malignancy for the Incomplete Retrieval of Suspicious Calcifications Diagnosed as Flat Epithelial Atypia or Atypical Ductal Hyperplasia by Stereotactic Vacuum-Assisted Breast Biopsy.
    Yu CC; Cheung YC; Ueng SH; Chen SC
    Korean J Radiol; 2020 Nov; 21(11):1220-1229. PubMed ID: 32729266
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Stereotactic core breast biopsy of malignant calcifications: diagnostic yield of cores with and cores without calcifications on specimen radiographs.
    Margolin FR; Kaufman L; Jacobs RP; Denny SR; Schrumpf JD
    Radiology; 2004 Oct; 233(1):251-4. PubMed ID: 15333764
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Utility of detection of breast calcifications with integrated real-time radiography system (IRRS) during digital breast tomosynthesis (DBT)-guided vacuum assisted biopsy (VAB): initial single-center experience.
    Giambersio E; Depretto C; Trimboli RM; Di Leo G; D'Ascoli E; Della Pepa G; Irmici G; Rabiolo L; Scaperrotta GP
    Radiol Med; 2023 Jun; 128(6):699-703. PubMed ID: 37115391
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Ultrasonography-guided vacuum-assisted biopsy of microcalcifications: Comparison of the diagnostic yield of calcified cores and non-calcified cores on specimen radiographs.
    Cho N; Moon WK; Chang JM; Park SH; Lyou CY; Park IA
    Acta Radiol; 2010 Mar; 51(2):123-7. PubMed ID: 19912076
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Histological correlation of mammographically detected microcalcifications in stereotactic core biopsies.
    Dahlstrom JE; Jain S
    Pathology; 2001 Nov; 33(4):444-8. PubMed ID: 11827410
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Management of Lobular Neoplasia Found on Core Needle Biopsy Performed for Calcifications Using Precise Radiologic-Pathologic Correlation.
    Kunjummen J; Rodriguez K; Newell MS; Hanley K; Cohen MA
    AJR Am J Roentgenol; 2021 Jun; 216(6):1476-1485. PubMed ID: 33852331
    [No Abstract]   [Full Text] [Related]  

  • 8. Assessment of Breast Specimens With or Without Calcifications in Diagnosing Malignant and Atypia for Mammographic Breast Microcalcifications Without Mass: A STARD-Compliant Diagnostic Accuracy Article.
    Cheung YC; Juan YH; Ueng SH; Lo YF; Huang PC; Lin YC; Chen SC
    Medicine (Baltimore); 2015 Oct; 94(42):e1832. PubMed ID: 26496323
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Stereotactic 9-gauge vacuum-assisted breast biopsy, how many specimens are needed?
    den Dekker BM; van Diest PJ; de Waard SN; Verkooijen HM; Pijnappel RM
    Eur J Radiol; 2019 Nov; 120():108665. PubMed ID: 31563108
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Stereotactic core-needle biopsy of non-mass calcifications: outcome and accuracy at long-term follow-up.
    Han BK; Choe YH; Ko YH; Nam SJ; Kim JH; Yang JH
    Korean J Radiol; 2003; 4(4):217-23. PubMed ID: 14726638
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Radiography of microcalcifications in stereotaxic mammary core biopsy specimens.
    Liberman L; Evans WP; Dershaw DD; Hann LE; Deutch BM; Abramson AF; Rosen PP
    Radiology; 1994 Jan; 190(1):223-5. PubMed ID: 8259409
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Failure of stereotactic core needle biopsy in women recalled for suspicious calcifications at screening mammography: frequency, causes, and final outcome in a multi-institutional, observational follow-up study.
    Duijm LEM; Strobbe LJA; van Breest Smallenburg V; Vreuls W; Boerman T; van Beek HC; Op de Coul-Froger CL; Setz-Pels W; Voogd AC
    Eur Radiol; 2022 Nov; 32(11):7420-7429. PubMed ID: 35486173
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Segregation of radiographic calcifications in stereotactic core biopsies of breast: is it necessary?
    Easley S; Abdul-Karim FW; Klein N; Wang N
    Breast J; 2007; 13(5):486-9. PubMed ID: 17760670
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Stereotactic Biopsy of Segmental Breast Calcifications: Is Sampling of Anterior and Posterior Components Necessary?
    Raj SD; Sedgwick EL; Severs FJ; Hilsenbeck SG; Wang T; Sepulveda KA
    Acad Radiol; 2016 Jun; 23(6):682-6. PubMed ID: 27052522
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Causes of failure in removing calcium in microcalcification-only lesions using 11-gauge stereotactic vacuum-assisted breast biopsy.
    Gümüş H; Gümüş M; Devalia H; Mills P; Fish D; Jones P; Uyar A; Sever A
    Diagn Interv Radiol; 2012; 18(4):354-9. PubMed ID: 22477646
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Value of stereotactic 11-gauge vacuum-assisted breast biopsy in non-palpable suspicious calcifications: an eight-year single institution experience with 587 patients.
    Li S; Qu F; Yang Y; Wang L; Shen J; Shao Z
    Gland Surg; 2020 Oct; 9(5):1258-1266. PubMed ID: 33224800
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Stereotaxic 14-gauge breast biopsy: how many core biopsy specimens are needed?
    Liberman L; Dershaw DD; Rosen PP; Abramson AF; Deutch BM; Hann LE
    Radiology; 1994 Sep; 192(3):793-5. PubMed ID: 8058949
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Incidental intraductal papillomas (<2 mm) of the breast diagnosed on needle core biopsy do not need to be excised.
    Jaffer S; Bleiweiss IJ; Nagi C
    Breast J; 2013; 19(2):130-3. PubMed ID: 23336823
    [TBL] [Abstract][Full Text] [Related]  

  • 19. When have mammographic calcifications been adequately sampled at needle core biopsy?
    Bagnall MJ; Evans AJ; Wilson AR; Burrell H; Pinder SE; Ellis IO
    Clin Radiol; 2000 Jul; 55(7):548-53. PubMed ID: 10924380
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Calcifications in breast biopsy specimens: discrepancies in radiologic-pathologic identification.
    Stein MA; Karlan MS
    Radiology; 1991 Apr; 179(1):111-4. PubMed ID: 2006260
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.