BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

119 related articles for article (PubMed ID: 38422940)

  • 1. Design of simulated-gas calibration source and self-attenuation correction methods for radioactive noble gas measurement with HPGe detector.
    Wang S; Tuo F; Qiu XP; Xiao Y; Liang JC
    Appl Radiat Isot; 2024 Apr; 206():111248. PubMed ID: 38422940
    [TBL] [Abstract][Full Text] [Related]  

  • 2. A semi-empirical method for efficiency calibration of an HPGe detector against different sample densities.
    Nabil IM; El-Kourghly KM; El Sayed AF
    Appl Radiat Isot; 2023 Oct; 200():110946. PubMed ID: 37523863
    [TBL] [Abstract][Full Text] [Related]  

  • 3. HPGe detector photopeak efficiency calculation including self-absorption and coincidence corrections for Marinelli beaker sources using compact analytical expressions.
    Abbas MI
    Appl Radiat Isot; 2001 May; 54(5):761-8. PubMed ID: 11258525
    [TBL] [Abstract][Full Text] [Related]  

  • 4. A study for improving detection efficiency of an HPGe detector based gamma spectrometer using Monte Carlo simulation and genetic algorithms.
    Huy NQ; Binh DQ; An VX
    Appl Radiat Isot; 2012 Dec; 70(12):2695-702. PubMed ID: 23037923
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Dead layer estimation of an HPGe detector using MCNP6 and Geant4.
    Lee H; Sung SH; Shin SH; Kim HR
    Appl Radiat Isot; 2023 Feb; 192():110597. PubMed ID: 36508955
    [TBL] [Abstract][Full Text] [Related]  

  • 6. A new model calculation of the peak efficiency for HPGe detectors used in assays of radioactive waste drums.
    Stanga D; Radu D; Sima O
    Appl Radiat Isot; 2010; 68(7-8):1418-22. PubMed ID: 19945290
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Re-construction of a HPGe detector precise modeling for efficiency calibration.
    Zhang C; Hu G; Zeng J; Xiang Q; Guo X; Gong J
    Appl Radiat Isot; 2022 Feb; 180():110059. PubMed ID: 34929611
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Determination of detection efficiency on HPGe detector for point-like and volumetric samples based on Geant4 simulations.
    Lin M; Wang Y; Qin Z
    Appl Radiat Isot; 2023 Oct; 200():110989. PubMed ID: 37611498
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Efficiency corrections in determining the (137)Cs inventory of environmental soil samples by using relative measurement method and GEANT4 simulations.
    Li G; Liang Y; Xu J; Bai L
    J Environ Radioact; 2015 Aug; 146():94-101. PubMed ID: 25973538
    [TBL] [Abstract][Full Text] [Related]  

  • 10. A hybrid method to determine efficiency curve of HPGe detectors.
    Ozben CS; Emirhan EM
    Appl Radiat Isot; 2009 Jun; 67(6):1110-3. PubMed ID: 19297177
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Efficiency calibration and self-attenuation correction in radioxenon measurement using β-γ coincidence method.
    Li Q; Wang S; Fan Y; Zhao Y; Jia H; Zhang X; Zhang R
    J Environ Radioact; 2023 Jan; 256():107054. PubMed ID: 36330871
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Gamma-ray efficiency of a HPGe detector as a function of energy and geometry.
    Challan MB
    Appl Radiat Isot; 2013 Dec; 82():166-9. PubMed ID: 24007787
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Calibration of HPGe gamma-ray detectors for measurement of radioactive noble gas sources.
    Pibida L; Nafee SS; Unterweger M; Hammond MM; Karam L; Abbas MI
    Appl Radiat Isot; 2007 Feb; 65(2):225-33. PubMed ID: 16945546
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Direct and precise determination of environmental radionuclides in solid materials using a modified Marinelli beaker and a HPGe detector.
    Seo BK; Lee KY; Yoon YY; Lee DW
    Fresenius J Anal Chem; 2001 Jun; 370(2-3):264-9. PubMed ID: 11451249
    [TBL] [Abstract][Full Text] [Related]  

  • 15. X-ray radiography of HPGe detectors for Monte Carlo simulations.
    Pohuliai S; Vlasenko A; Malgin V; Kanapelka M
    Appl Radiat Isot; 2023 Aug; 198():110837. PubMed ID: 37150104
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Self-absorption correction for gamma spectrometry of powdered milk samples using Marinelli beaker.
    Melquiades FL; Appoloni CR
    Appl Radiat Isot; 2001 Nov; 55(5):697-700. PubMed ID: 11573804
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Comparison of simulated and experimental values of self-absorption correction factors for a fast and credible adjust in efficiency curve of gamma spectroscopy.
    Lopes JM; Medeiros MPC; Garcêz RWD; Filgueiras RA; Thalhofer JL; Silva Júnior WFR; Silva AX
    Appl Radiat Isot; 2018 Nov; 141():241-245. PubMed ID: 29759888
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Calibration of stack monitors for measurement of noble gases in nuclear facilities.
    Kovar P; Dryak P; Suran J; Gudelis A
    Appl Radiat Isot; 2012 Sep; 70(9):2127-9. PubMed ID: 22424839
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Experimental and MC determination of HPGe detector efficiency in the 40-2754 keV energy range for measuring point source geometry with the source-to-detector distance of 25 cm.
    Dryak P; Kovar P
    Appl Radiat Isot; 2006; 64(10-11):1346-9. PubMed ID: 16564693
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Application of ISOCS system in the laboratory efficiency calibration.
    Grządziel D; Kozak K; Mazur J; Mroczek M
    J Environ Radioact; 2018 Aug; 188():95-99. PubMed ID: 29029764
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.