These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

121 related articles for article (PubMed ID: 38432424)

  • 1. Electrocardiographic predictors of atrial mechanical sensing in leadless pacemakers.
    Hofer D; Perucchini F; Blessberger H; Steinwender C; Zehetleitner S; Molitor N; Saguner AM; El-Chami MF; Black G; Schiavone M; Forleo G; Gasperetti A; Steffel J; Noti F; Haeberlin A; Breitenstein A
    Heart Rhythm; 2024 Jul; 21(7):1072-1080. PubMed ID: 38432424
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Predictor of A4 amplitude using preprocedural electrocardiography in patients with leadless pacemakers.
    Kawatani S; Kotake Y; Takami A; Nakamura K; Tomomori T; Okamura A; Kato M; Yamamoto K
    Heart Rhythm; 2024 Jul; 21(7):1064-1071. PubMed ID: 38382683
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Predictors of atrial mechanical sensing and atrioventricular synchrony with a leadless ventricular pacemaker: Results from the MARVEL 2 Study.
    Garweg C; Khelae SK; Steinwender C; Chan JYS; Ritter P; Johansen JB; Sagi V; Epstein LM; Piccini JP; Pascual M; Mont L; Willems R; Sheldon T; Splett V; Stromberg K; Wood N; Chinitz L
    Heart Rhythm; 2020 Dec; 17(12):2037-2045. PubMed ID: 32717315
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Atrioventricular Synchronous Pacing Using a Leadless Ventricular Pacemaker: Results From the MARVEL 2 Study.
    Steinwender C; Khelae SK; Garweg C; Chan JYS; Ritter P; Johansen JB; Sagi V; Epstein LM; Piccini JP; Pascual M; Mont L; Sheldon T; Splett V; Stromberg K; Wood N; Chinitz L
    JACC Clin Electrophysiol; 2020 Jan; 6(1):94-106. PubMed ID: 31709982
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Atrial mechanical contraction and ambulatory atrioventricular synchrony: Predictors from the OPTIVALL study.
    Briongos-Figuero S; Estévez Paniagua Á; Sánchez Hernández A; Jiménez Loeches S; Gómez Mariscal E; Vaqueriza Cubillo D; Muñoz-Aguilera R
    J Cardiovasc Electrophysiol; 2023 Sep; 34(9):1904-1913. PubMed ID: 37482952
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Accelerometer-based atrioventricular synchronous pacing with a ventricular leadless pacemaker: Results from the Micra atrioventricular feasibility studies.
    Chinitz L; Ritter P; Khelae SK; Iacopino S; Garweg C; Grazia-Bongiorni M; Neuzil P; Johansen JB; Mont L; Gonzalez E; Sagi V; Duray GZ; Clementy N; Sheldon T; Splett V; Stromberg K; Wood N; Steinwender C
    Heart Rhythm; 2018 Sep; 15(9):1363-1371. PubMed ID: 29758405
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Leadless atrioventricular synchronous pacing in an outpatient setting: Early lessons learned on factors affecting atrioventricular synchrony.
    Neugebauer F; Noti F; van Gool S; Roten L; Baldinger SH; Seiler J; Madaffari A; Servatius H; Ryser A; Tanner H; Reichlin T; Haeberlin A
    Heart Rhythm; 2022 May; 19(5):748-756. PubMed ID: 34971817
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Dual chamber cardiac pacing in children: Single chamber pacing dual chamber sensing cardiac pacemaker or dual chamber pacing and sensing cardiac pacemaker?
    Bostan OM; Celiker A; Karagöz T; Ozer S; Ozme S
    Pediatr Int; 2002 Dec; 44(6):635-40. PubMed ID: 12421261
    [TBL] [Abstract][Full Text] [Related]  

  • 9. VDD(R) pacing: short- and long-term stability of atrial sensing with a single lead system.
    Naegeli B; Osswald S; Pfisterer M; Burkart F
    Pacing Clin Electrophysiol; 1996 Apr; 19(4 Pt 1):455-64. PubMed ID: 8848393
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Long-term efficacy and stability of atrial sensing in VDD pacing.
    Huang CY; Tuan TC; Lee WS; Cheng CM; Lin SJ; Kong CW
    Clin Cardiol; 2005 Apr; 28(4):203-7. PubMed ID: 15869057
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Single lead VDD pacing: multicenter study.
    Ovsyscher IE; Katz A; Rosenheck S; Erdman S; Bondy C
    Pacing Clin Electrophysiol; 1996 Nov; 19(11 Pt 2):1768-71. PubMed ID: 8945037
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Experience and implantation techniques with a new single-pass lead VDD pacing system.
    Longo E; Catrini V
    Pacing Clin Electrophysiol; 1990 Jul; 13(7):927-36. PubMed ID: 1695750
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Comparison of first- and second-generation leadless pacemakers in patients with sinus rhythm and complete atrioventricular block.
    Lenormand T; Abou Khalil K; Bodin A; Babuty D; Bisson A; Clementy N
    J Cardiovasc Electrophysiol; 2023 Aug; 34(8):1730-1737. PubMed ID: 37354448
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Atrial sensing and AV synchrony in single lead VDD pacemakers: a prospective comparison to DDD devices with bipolar atrial leads.
    Wiegand UK; Bode F; Schneider R; Taubert G; Brandes A; Peters W; Katus HA; Potratz J
    J Cardiovasc Electrophysiol; 1999 Apr; 10(4):513-20. PubMed ID: 10355692
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Correlation between AV synchrony and device collected AM-VP sequence counter in atrioventricular synchronous leadless pacemakers: A real-world assessment.
    Garweg C; Piccini JP; Epstein LM; Frazier-Mills C; Chinitz LA; Steinwender C; Stromberg K; Sheldon T; Fagan DH; El-Chami MF
    J Cardiovasc Electrophysiol; 2023 Jan; 34(1):197-206. PubMed ID: 36317470
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Implantation strategy of the atrial dipole impacts atrial sensing performance of single lead VDD pacemakers.
    Wiegand UK; Nowak B; Reisp U; Peiffer T; Bode F; Potratz J;
    Pacing Clin Electrophysiol; 2002 Mar; 25(3):316-23. PubMed ID: 11990661
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Long-term outcome of atrial synchronous mode pacing in patients with atrioventricular block using a single lead.
    Blich M; Suleiman M; Shwiri TZ; Marai I; Boulos M; Amikam S
    Clin Cardiol; 2010 Jan; 33(1):18-22. PubMed ID: 20063297
    [TBL] [Abstract][Full Text] [Related]  

  • 18. P wave recognition and atrial stimulation with fractally iridium coated VDD single pass leads.
    Res JC; Reijsoo FJ; van Woersem RJ; Middelhoff CJ; van Kalmthout PM; Zwart P; Westendorp P
    Pacing Clin Electrophysiol; 1994 Nov; 17(11 Pt 2):1883-8. PubMed ID: 7845786
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Immediate and long-term atrial sensing stability in single-lead VDD pacing depends on right atrial dimensions.
    Santini M; Ricci R; Pignalberi C; Auriti A; Pepe M; Assale R; Caporicci D
    Europace; 2001 Oct; 3(4):324-31. PubMed ID: 11678392
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Optimizing atrial sensing parameters in leadless pacemakers: Atrioventricular synchrony achievement in the real world.
    Briongos-Figuero S; Estévez-Paniagua Á; Sánchez Hernández A; Jiménez S; Gómez-Mariscal E; Abad Motos A; Muñoz-Aguilera R
    Heart Rhythm; 2022 Dec; 19(12):2011-2018. PubMed ID: 35952980
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.