These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

130 related articles for article (PubMed ID: 38435386)

  • 41. Effect of Mask Selection on the Leak Test in Ventilators Designed for Noninvasive Ventilation.
    Tan W; Hou HJ; Lu CL; Dai B; Zhao HW; Wang W; Kang J
    Respir Care; 2022 May; 67(5):572-578. PubMed ID: 35292521
    [TBL] [Abstract][Full Text] [Related]  

  • 42. Nitrogen dioxide production during mechanical ventilation with nitric oxide in adults. Effects of ventilator internal volume, air versus nitrogen dilution, minute ventilation, and inspired oxygen fraction.
    Nishimura M; Hess D; Kacmarek RM; Ritz R; Hurford WE
    Anesthesiology; 1995 May; 82(5):1246-54. PubMed ID: 7741300
    [TBL] [Abstract][Full Text] [Related]  

  • 43. Combined Ventilation of Two Subjects with a Single Mechanical Ventilator Using a New Medical Device: An In Vitro Study.
    Lugones I; Ramos M; Biancolini MF; Orofino Giambastiani R
    Anesthesiol Res Pract; 2021; 2021():6691591. PubMed ID: 33628233
    [TBL] [Abstract][Full Text] [Related]  

  • 44. Are tidal volume measurements in neonatal pressure-controlled ventilation accurate?
    Chow LC; Vanderhal A; Raber J; Sola A
    Pediatr Pulmonol; 2002 Sep; 34(3):196-202. PubMed ID: 12203848
    [TBL] [Abstract][Full Text] [Related]  

  • 45. The Difference Between Set and Delivered Tidal Volume: A Lung Simulation Study.
    Yamaguchi Y; Miyashita T; Matsuda Y; Sasaki M; Takaki S; Kim SS; Tobias JD; Goto T
    Med Devices (Auckl); 2020; 13():205-211. PubMed ID: 32765126
    [TBL] [Abstract][Full Text] [Related]  

  • 46. A Novel Ventilator Design for COVID-19 and Resource-Limited Settings.
    Madekurozwa M; Bonneuil WV; Frattolin J; Watson DJ; Moore AC; Stevens MM; Moore J; Mathiszig-Lee J; van Batenburg-Sherwood J
    Front Med Technol; 2021; 3():707826. PubMed ID: 35047946
    [TBL] [Abstract][Full Text] [Related]  

  • 47. [Standard technical specifications for methacholine chloride (Methacholine) bronchial challenge test (2023)].
    ; ;
    Zhonghua Jie He He Hu Xi Za Zhi; 2024 Feb; 47(2):101-119. PubMed ID: 38309959
    [TBL] [Abstract][Full Text] [Related]  

  • 48. Reliability of Displayed Tidal Volume in Healthy and Surfactant-Depleted Piglets.
    Mendiondo Luedloff AC; Thurman TL; Holt SJ; Bai S; Heulitt MJ; Courtney SE
    Respir Care; 2016 Dec; 61(12):1605-1612. PubMed ID: 27899539
    [TBL] [Abstract][Full Text] [Related]  

  • 49. Preliminary Design and Development of a Mechanical Ventilator Using Industrial Automation Components for Rapid Deployment During the COVID-19 Pandemic.
    DeBoer B; Barari A; Nonoyama M; Dubrowski A; Zaccagnini M; Hosseini A
    Cureus; 2021 Dec; 13(12):e20386. PubMed ID: 35036217
    [TBL] [Abstract][Full Text] [Related]  

  • 50. Filters Alter the Performance of Noninvasive Ventilators.
    Tolson J; Hone R; Bandiera C; Rautela L; Churchward TJ; Ridgers A; Howard ME; Worsnop CJ
    Respir Care; 2022 Jul; 67(7):795-800. PubMed ID: 35610028
    [TBL] [Abstract][Full Text] [Related]  

  • 51. Pre-clinical validation of a turbine-based ventilator for invasive ventilation-The ACUTE-19 ventilator.
    Alonso-Iñigo JM; Mazzinari G; Casañ-Pallardó M; Redondo-García JI; Viscasillas-Monteagudo J; Gutierrez-Bautista A; Ramirez-Faz J; Alonso-Pérez P; Díaz-Lobato S; Neto AS; Diaz-Cambronero O; Argente-Navarro P; Gama de Abreu M; Pelosi P; Schultz MJ;
    Rev Esp Anestesiol Reanim (Engl Ed); 2022 Nov; 69(9):544-555. PubMed ID: 36244956
    [TBL] [Abstract][Full Text] [Related]  

  • 52. Volume-Targeted Ventilation in the Neonate: Benchmarking Ventilators on an Active Lung Model.
    Krieger TJ; Wald M
    Pediatr Crit Care Med; 2017 Mar; 18(3):241-248. PubMed ID: 28121833
    [TBL] [Abstract][Full Text] [Related]  

  • 53. Performance of neonatal ventilators in volume targeted ventilation mode.
    Sharma A; Milner AD; Greenough A
    Acta Paediatr; 2007 Feb; 96(2):176-80. PubMed ID: 17429900
    [TBL] [Abstract][Full Text] [Related]  

  • 54. Increasing ventilator surge capacity in COVID 19 pandemic: design, manufacture and in vitro-in vivo testing in anaesthetized healthy pigs of a rapid prototyped mechanical ventilator.
    Dhanani J; Pang G; Pincus J; Ahern B; Goodwin W; Cowling N; Whitten G; Abdul-Aziz MH; Martin S; Corke P; Laupland KB
    BMC Res Notes; 2020 Sep; 13(1):421. PubMed ID: 32894167
    [TBL] [Abstract][Full Text] [Related]  

  • 55. [Evaluation of tidal volume delivered by ventilators during volume-controlled ventilation].
    Zhou J; Yan Y; Cao D
    Zhonghua Wei Zhong Bing Ji Jiu Yi Xue; 2014 Dec; 26(12):875-8. PubMed ID: 25476079
    [TBL] [Abstract][Full Text] [Related]  

  • 56. Maintaining a high inspired oxygen fraction with the Elisée 350 turbine transport ventilator connected to two portable oxygen concentrators in an austere environment.
    Cardinale M; Cungi PJ; Bordes J; Cohergne F; Schmitt S; Langlois A; Meaudre E; Lacroix G
    J Trauma Acute Care Surg; 2020 Sep; 89(3):e59-e63. PubMed ID: 32467466
    [TBL] [Abstract][Full Text] [Related]  

  • 57. Increasing ventilator surge capacity in disasters: ventilation of four adult-human-sized sheep on a single ventilator with a modified circuit.
    Paladino L; Silverberg M; Charchaflieh JG; Eason JK; Wright BJ; Palamidessi N; Arquilla B; Sinert R; Manoach S
    Resuscitation; 2008 Apr; 77(1):121-6. PubMed ID: 18164798
    [TBL] [Abstract][Full Text] [Related]  

  • 58. Inaccuracies of nitric oxide delivery systems during adult mechanical ventilation.
    Imanaka H; Hess D; Kirmse M; Bigatello LM; Kacmarek RM; Steudel W; Hurford WE
    Anesthesiology; 1997 Mar; 86(3):676-88. PubMed ID: 9066335
    [TBL] [Abstract][Full Text] [Related]  

  • 59. In vitro performance comparison of the Sensormedics 3100A and B high-frequency oscillatory ventilators.
    Custer JW; Ahmed A; Kaczka DW; Mulreany DG; Hager DN; Simon BA; Easley RB
    Pediatr Crit Care Med; 2011 Jul; 12(4):e176-80. PubMed ID: 21037502
    [TBL] [Abstract][Full Text] [Related]  

  • 60. Multiplex Ventilation: A Simulation-Based Study of Ventilating 2 Patients With a Single Ventilator.
    Chatburn RL; Branson RD; Hatipoğlu U
    Respir Care; 2020 Jul; 65(7):920-931. PubMed ID: 32345741
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 7.