These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
117 related articles for article (PubMed ID: 38437891)
1. Evaluation of the in vivo chemical reactivity of a novel copolymer insulation on cardiac leads in a single-center study. Ibrahim R; Chaffin K; Shah A; Westerman S; Lloyd M; Bhatia N; Merchant FM; El-Chami M Heart Rhythm; 2024 Aug; 21(8):1334-1341. PubMed ID: 38437891 [TBL] [Abstract][Full Text] [Related]
2. Biodegradation of polyether polyurethane inner insulation in bipolar pacemaker leads. Wiggins MJ; Wilkoff B; Anderson JM; Hiltner A J Biomed Mater Res; 2001 May; 58(3):302-7. PubMed ID: 11319745 [TBL] [Abstract][Full Text] [Related]
3. Systematic fluoroscopic and electrical assessment of implantable cardioverter-defibrillator patients implanted with silicone-polyurethane copolymer (Optim™) coated leads. Forleo GB; Di Biase L; Panattoni G; Politano A; Magliano G; Santini L; Natale A; Romeo F Europace; 2014 Feb; 16(2):265-70. PubMed ID: 24042736 [TBL] [Abstract][Full Text] [Related]
4. Effects of electrocautery on transvenous lead insulation materials. Lim KK; Reddy S; Desai S; Smelley M; Kim SS; Beshai JF; Lin AC; Burke MC; Knight BP J Cardiovasc Electrophysiol; 2009 Apr; 20(4):429-35. PubMed ID: 19017342 [TBL] [Abstract][Full Text] [Related]
6. Detection of high-frequency artifact as a function of pulse generator algorithms and outer-insulation material. Narui R; Nakamura T; Nakajima I; Norton CA; Kim EJ; Holmes BB; Stevenson WG; John RM; Ellis CR; Crossley GH; Montgomery JA Heart Rhythm; 2019 Dec; 16(12):1855-1861. PubMed ID: 31125674 [TBL] [Abstract][Full Text] [Related]
7. Failure of a novel silicone-polyurethane copolymer (Optim™) to prevent implantable cardioverter-defibrillator lead insulation abrasions. Hauser RG; Abdelhadi RH; McGriff DM; Kallinen Retel L Europace; 2013 Feb; 15(2):278-83. PubMed ID: 22915789 [TBL] [Abstract][Full Text] [Related]
8. The Canadian experience with Durata and Riata ST Optim defibrillator leads: a report from the Canadian Heart Rhythm Society Device Committee. Bennett MT; Ha AC; Exner DV; Tung SK; Parkash R; Connors S; Coutu B; Crystal E; Champagne J; Philippon F; Yee R; Stephenson EA; Nery PB; Essebag V; Sanatani S; Redfearn D; Krahn AD; Healey JS Heart Rhythm; 2013 Oct; 10(10):1478-81. PubMed ID: 23973950 [TBL] [Abstract][Full Text] [Related]
9. Characterization of Outer Insulation in Long-Term-Implanted Leads. Tohfafarosh M; Sevit A; Patel J; Kiel JW; Greenspon A; Prutkin JM; Kurtz SM J Long Term Eff Med Implants; 2016; 26(3):225-232. PubMed ID: 28134605 [TBL] [Abstract][Full Text] [Related]
10. Long-term performance of a pacing lead family: A single-center experience. El-Chami MF; Rao B; Shah AD; Wood C; Sayegh M; Zakka P; Ginn K; Pallotta L; Evans B; Hoskins MH; Delurgio D; Lloyd M; Langberg J; Leon AR; Merchant FM Heart Rhythm; 2019 Apr; 16(4):572-578. PubMed ID: 30366161 [TBL] [Abstract][Full Text] [Related]
11. Riata implantable cardioverter-defibrillator lead failure: analysis of explanted leads with a unique insulation defect. Hauser RG; McGriff D; Retel LK Heart Rhythm; 2012 May; 9(5):742-9. PubMed ID: 22209723 [TBL] [Abstract][Full Text] [Related]
12. Endocardial silicone lead wear: description of tribological phenomena on the basis of microscopic examination of removed leads. Preliminary report. Małecka B; Ząbek A; Ciaś A; Stępiński J; Kutarski A; Rońda J; Lelakowski J; Małecki J Kardiol Pol; 2014; 72(10):960-8. PubMed ID: 24846370 [TBL] [Abstract][Full Text] [Related]
13. Sudden and Fatal Malfunction of a Durata Defibrillator Lead due to External Insulation Failure. Shah AD; Hirsh DS; Langberg JJ Pacing Clin Electrophysiol; 2016 Jan; 39(1):101-4. PubMed ID: 26293817 [TBL] [Abstract][Full Text] [Related]
14. Bipolar leads for use with permanently implantable cardiac pacing systems: a review of limitations of traditional and coaxial configurations and the development and testing of new conductor, insulation, and electrode designs. Tyers GF; Mills P; Clark J; Cheesman M; Yeung-Lai-Wah JA; Brownlee RR J Invest Surg; 1997; 10(1-2):1-15. PubMed ID: 9100169 [TBL] [Abstract][Full Text] [Related]
15. Large, single-center, single-operator experience with transvenous lead extraction: outcomes and changing indications. Jones SO; Eckart RE; Albert CM; Epstein LM Heart Rhythm; 2008 Apr; 5(4):520-5. PubMed ID: 18325849 [TBL] [Abstract][Full Text] [Related]
16. Insulation lead failure: is it a matter of insulation coating, venous approach, or both? Antonelli D; Rosenfeld T; Freedberg NA; Palma E; Gross JN; Furman S Pacing Clin Electrophysiol; 1998 Feb; 21(2):418-21. PubMed ID: 9507543 [TBL] [Abstract][Full Text] [Related]
17. Performance of the St. Jude Medical Riata leads. Epstein AE; Baker JH; Beau SL; Deering TF; Greenberg SM; Goldman DS Heart Rhythm; 2009 Feb; 6(2):204-9. PubMed ID: 19103512 [TBL] [Abstract][Full Text] [Related]
18. Long-term in vivo biostability of poly(dimethylsiloxane)/poly(hexamethylene oxide) mixed macrodiol-based polyurethane elastomers. Simmons A; Hyvarinen J; Odell RA; Martin DJ; Gunatillake PA; Noble KR; Poole-Warren LA Biomaterials; 2004 Sep; 25(20):4887-900. PubMed ID: 15109849 [TBL] [Abstract][Full Text] [Related]
19. A Comparative Study of Defibrillator Leads at a Large-Volume Implanting Hospital: Results From the Pacemaker and Implantable Defibrillator Leads Survival Study ("PAIDLESS"). Cohen TJ; Asheld WJ; Germano J; Islam S; Patel D J Invasive Cardiol; 2015 Jun; 27(6):292-300. PubMed ID: 26028656 [TBL] [Abstract][Full Text] [Related]
20. Failure of implantable cardioverter-defibrillator leads: a matter of lead size? Rordorf R; Poggio L; Savastano S; Vicentini A; Petracci B; Chieffo E; Klersy C; Landolina M Heart Rhythm; 2013 Feb; 10(2):184-90. PubMed ID: 23063430 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]