142 related articles for article (PubMed ID: 38443143)
1. Real-Time Effects of Disconnection of the Ventilator on Regional Lung Volumes and Ventilation Distribution.
Minaříková P; Borges JB; Duška F; Zvoníček V
Respir Care; 2024 Apr; 69(5):608-612. PubMed ID: 38443143
[No Abstract] [Full Text] [Related]
2. The time taken for the regional distribution of ventilation to stabilise: an investigation using electrical impedance tomography.
Caruana L; Paratz JD; Chang A; Barnett AG; Fraser JF
Anaesth Intensive Care; 2015 Jan; 43(1):88-91. PubMed ID: 25579294
[TBL] [Abstract][Full Text] [Related]
3. Clinical implication of monitoring regional ventilation using electrical impedance tomography.
Shono A; Kotani T
J Intensive Care; 2019; 7():4. PubMed ID: 30680219
[TBL] [Abstract][Full Text] [Related]
4. Bedside assessment of the effects of positive end-expiratory pressure on lung inflation and recruitment by the helium dilution technique and electrical impedance tomography.
Mauri T; Eronia N; Turrini C; Battistini M; Grasselli G; Rona R; Volta CA; Bellani G; Pesenti A
Intensive Care Med; 2016 Oct; 42(10):1576-1587. PubMed ID: 27518321
[TBL] [Abstract][Full Text] [Related]
5. Mechanical ventilation guided by electrical impedance tomography in experimental acute lung injury.
Wolf GK; Gómez-Laberge C; Rettig JS; Vargas SO; Smallwood CD; Prabhu SP; Vitali SH; Zurakowski D; Arnold JH
Crit Care Med; 2013 May; 41(5):1296-304. PubMed ID: 23474677
[TBL] [Abstract][Full Text] [Related]
6. Electrical Impedance Tomography During Mechanical Ventilation.
Walsh BK; Smallwood CD
Respir Care; 2016 Oct; 61(10):1417-24. PubMed ID: 27682815
[TBL] [Abstract][Full Text] [Related]
7. Performance of electrical impedance tomography in detecting regional tidal volumes during one-lung ventilation.
Pulletz S; Elke G; Zick G; Schädler D; Scholz J; Weiler N; Frerichs I
Acta Anaesthesiol Scand; 2008 Sep; 52(8):1131-9. PubMed ID: 18840115
[TBL] [Abstract][Full Text] [Related]
8. Reproducibility of regional lung ventilation distribution determined by electrical impedance tomography during mechanical ventilation.
Frerichs I; Schmitz G; Pulletz S; Schädler D; Zick G; Scholz J; Weiler N
Physiol Meas; 2007 Jul; 28(7):S261-7. PubMed ID: 17664640
[TBL] [Abstract][Full Text] [Related]
9. Imaging of regional air distributions in porcine lungs using high-performance electrical impedance tomography system.
Jang GY; Kim YB; Wi H; Oh TI; Chung CR; Suh GY; Woo EJ
Annu Int Conf IEEE Eng Med Biol Soc; 2017 Jul; 2017():349-351. PubMed ID: 29059882
[TBL] [Abstract][Full Text] [Related]
10. Gravity-dependent ventilation distribution in rats measured with electrical impedance tomography.
Rooney D; Friese M; Fraser JF; R Dunster K; Schibler A
Physiol Meas; 2009 Oct; 30(10):1075-85. PubMed ID: 19738318
[TBL] [Abstract][Full Text] [Related]
11. Monitoring regional lung ventilation by functional electrical impedance tomography during assisted ventilation.
Frerichs I; Hahn G; Schiffmann H; Berger C; Hellige G
Ann N Y Acad Sci; 1999 Apr; 873():493-505. PubMed ID: 10372185
[TBL] [Abstract][Full Text] [Related]
12. Electrical impedance tomography guided ventilation therapy.
Putensen C; Wrigge H; Zinserling J
Curr Opin Crit Care; 2007 Jun; 13(3):344-50. PubMed ID: 17468569
[TBL] [Abstract][Full Text] [Related]
13. EIT monitors valid and robust regional ventilation distribution in pathologic ventilation states in porcine study using differential DualEnergy-CT (ΔDECT).
Reinartz SD; Imhoff M; Tolba R; Fischer F; Fischer EG; Teschner E; Koch S; Gärber Y; Isfort P; Gremse F
Sci Rep; 2019 Jul; 9(1):9796. PubMed ID: 31278297
[TBL] [Abstract][Full Text] [Related]
14. Lung Volume Measurement and Ventilation Distribution During Invasive Mechanical Ventilation.
Piraino T
Respir Care; 2020 Jun; 65(6):760-771. PubMed ID: 32457169
[TBL] [Abstract][Full Text] [Related]
15. Regional pulmonary effects of bronchoalveolar lavage procedure determined by electrical impedance tomography.
Frerichs I; Dargaville PA; Rimensberger PC
Intensive Care Med Exp; 2019 Feb; 7(1):11. PubMed ID: 30771111
[TBL] [Abstract][Full Text] [Related]
16. Respiratory Support Effects over Time on Regional Lung Ventilation Assessed by Electrical Impedance Tomography in Premature Infants.
Virsilas E; Valiulis A; Kubilius R; Peciuliene S; Liubsys A
Medicina (Kaunas); 2024 Mar; 60(3):. PubMed ID: 38541220
[No Abstract] [Full Text] [Related]
17. Imbalances in regional lung ventilation: a validation study on electrical impedance tomography.
Victorino JA; Borges JB; Okamoto VN; Matos GF; Tucci MR; Caramez MP; Tanaka H; Sipmann FS; Santos DC; Barbas CS; Carvalho CR; Amato MB
Am J Respir Crit Care Med; 2004 Apr; 169(7):791-800. PubMed ID: 14693669
[TBL] [Abstract][Full Text] [Related]
18. Integrated EIT system for functional lung ventilation imaging.
Jang GY; Ayoub G; Kim YE; Oh TI; Chung CR; Suh GY; Woo EJ
Biomed Eng Online; 2019 Jul; 18(1):83. PubMed ID: 31345220
[TBL] [Abstract][Full Text] [Related]
19. Effect of general anesthesia and controlled mechanical ventilation on pulmonary ventilation distribution assessed by electrical impedance tomography in healthy children.
Nascimento MS; Rebello CM; Costa ELV; Corrêa LC; Alcala GC; Rossi FS; Morais CCA; Laurenti E; Camara MC; Iasi M; Apezzato MLP; do Prado C; Amato MBP
PLoS One; 2023; 18(3):e0283039. PubMed ID: 36928465
[TBL] [Abstract][Full Text] [Related]
20. Initial Observations on the Effect of Repeated Surfactant Dose on Lung Volume and Ventilation in Neonatal Respiratory Distress Syndrome.
Kallio M; van der Zwaag AS; Waldmann AD; Rahtu M; Miedema M; Papadouri T; van Kaam AH; Rimensberger PC; Bayford R; Frerichs I
Neonatology; 2019; 116(4):385-389. PubMed ID: 31505498
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]