179 related articles for article (PubMed ID: 38457423)
1. A meta-analysis comparing the efficacy of mineralized collagen-polymethylmethacrylate and polymethylmethacrylate bone cements in the treatment of vertebral compression fractures.
Li SF; Li XY; Bai XH; Wang YL; Han PF; Li HZ
PLoS One; 2024; 19(3):e0299325. PubMed ID: 38457423
[TBL] [Abstract][Full Text] [Related]
2. Biomechanical evaluation of calcium phosphate-based nanocomposite versus polymethylmethacrylate cement for percutaneous kyphoplasty.
Lu Q; Liu C; Wang D; Liu H; Yang H; Yang L
Spine J; 2019 Nov; 19(11):1871-1884. PubMed ID: 31202837
[TBL] [Abstract][Full Text] [Related]
3. Mineralized Collagen Modified Polymethyl Methacrylate Bone Cement for Osteoporotic Compression Vertebral Fracture at 1-Year Follow-up.
Zhu J; Zhang K; Luo K; Qiu Z; Yang S; Cui F; Weng X; Jiang G
Spine (Phila Pa 1976); 2019 Jun; 44(12):827-838. PubMed ID: 30601358
[TBL] [Abstract][Full Text] [Related]
4. [Clinical comparison of polymethylmethacrylate and bone cement in the treatment of osteoporotic vertebral compression fractures: a retrospective study].
Shang LP; Tian Y; Liu XG
Beijing Da Xue Xue Bao Yi Xue Ban; 2017 Apr; 49(2):267-273. PubMed ID: 28416837
[TBL] [Abstract][Full Text] [Related]
5. Vertebroplasty versus kyphoplasty in osteoporotic vertebral compression fracture: a meta-analysis of prospective comparative studies.
Chang X; Lv YF; Chen B; Li HY; Han XB; Yang K; Zhang W; Zhou Y; Li CQ
Int Orthop; 2015 Mar; 39(3):491-500. PubMed ID: 25260399
[TBL] [Abstract][Full Text] [Related]
6. Comparison of the Efficacy and Safety of Bone-filling Mesh Container and Simple Percutaneous Balloon Kyphoplasty in the Treatment of Osteoporotic Vertebral Compression Fractures.
He CJ; Liu GD
Pain Physician; 2018 May; 21(3):259-268. PubMed ID: 29871370
[TBL] [Abstract][Full Text] [Related]
7. Clinical outcome comparison of polymethylmethacrylate bone cement with and without mineralized collagen modification for osteoporotic vertebral compression fractures.
Wang X; Kou JM; Yue Y; Weng XS; Qiu ZY; Zhang XF
Medicine (Baltimore); 2018 Sep; 97(37):e12204. PubMed ID: 30212950
[TBL] [Abstract][Full Text] [Related]
8. Long-term follow-up study of osteoporotic vertebral compression fracture treated using balloon kyphoplasty and vertebroplasty.
Liu JT; Li CS; Chang CS; Liao WJ
J Neurosurg Spine; 2015 Jul; 23(1):94-8. PubMed ID: 25884343
[TBL] [Abstract][Full Text] [Related]
9. [Effect of percutaneous kyphoplasty with different phases bone cement for treatment of osteoporotic vertebral compression fractures].
Liu Z; Zhou Y; Lei F; Ye F; Zhou Q; Zheng L; Feng D
Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi; 2020 Apr; 34(4):435-441. PubMed ID: 32291977
[TBL] [Abstract][Full Text] [Related]
10. [Effectiveness of unilateral percutaneous vertebroplasty for elderly osteoporotic vertebral compression fracture by different approaches with different symptom severity].
Xu H; Yang J; Liu T; He B; Chai X; Hao D
Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi; 2023 Feb; 37(2):168-173. PubMed ID: 36796811
[TBL] [Abstract][Full Text] [Related]
11. Comparison of Percutaneous Vertebroplasty and Balloon Kyphoplasty for the Treatment of Single Level Vertebral Compression Fractures: A Meta-analysis of the Literature.
Wang H; Sribastav SS; Ye F; Yang C; Wang J; Liu H; Zheng Z
Pain Physician; 2015; 18(3):209-22. PubMed ID: 26000665
[TBL] [Abstract][Full Text] [Related]
12. Comparison of percutaneous balloon dilation kyphoplasty and percutaneous vertebroplasty in treatment for thoracolumbar vertebral compression fractures.
Hu KZ; Chen SC; Xu L
Eur Rev Med Pharmacol Sci; 2018 Jul; 22(1 Suppl):96-102. PubMed ID: 30004560
[TBL] [Abstract][Full Text] [Related]
13. Bioactive poly (methyl methacrylate) bone cement for the treatment of osteoporotic vertebral compression fractures.
Zhu J; Yang S; Cai K; Wang S; Qiu Z; Huang J; Jiang G; Wang X; Fang X
Theranostics; 2020; 10(14):6544-6560. PubMed ID: 32483469
[No Abstract] [Full Text] [Related]
14. Analysis of two minimally invasive procedures for osteoporotic vertebral compression fractures with intravertebral cleft: a systematic review and meta-analysis.
Wei H; Dong C; Zhu Y; Ma H
J Orthop Surg Res; 2020 Sep; 15(1):401. PubMed ID: 32912267
[TBL] [Abstract][Full Text] [Related]
15. Balloon kyphoplasty versus vertebroplasty for treatment of osteoporotic vertebral compression fracture: a prospective, comparative, and randomized clinical study.
Liu JT; Liao WJ; Tan WC; Lee JK; Liu CH; Chen YH; Lin TB
Osteoporos Int; 2010 Feb; 21(2):359-64. PubMed ID: 19513578
[TBL] [Abstract][Full Text] [Related]
16. Percutaneous Vertebroplasty with the Polymethyl Methacrylate - Gelatin Sponge Complex in the Treatment of Patients with Osteoporotic Vertebral Compression Fractures Accompanied by Superior Endplate Injurie.
Wang YQ; Qiao L; Wang B; Tang XB; Liao YF; Zhou CQ; Cao ZG; Li H
Turk Neurosurg; 2024; 34(1):74-80. PubMed ID: 37144650
[TBL] [Abstract][Full Text] [Related]
17. Percutaneous vertebroplasty with high- versus low-viscosity bone cement for osteoporotic vertebral compression fractures.
Miao F; Zeng X; Wang W; Zhao Z
J Orthop Surg Res; 2020 Aug; 15(1):302. PubMed ID: 32762763
[TBL] [Abstract][Full Text] [Related]
18. Comparison of high-viscosity cement vertebroplasty and balloon kyphoplasty for the treatment of osteoporotic vertebral compression fractures.
Wang CH; Ma JZ; Zhang CC; Nie L
Pain Physician; 2015; 18(2):E187-94. PubMed ID: 25794218
[TBL] [Abstract][Full Text] [Related]
19. Balloon kyphoplasty versus percutaneous vertebroplasty for osteoporotic vertebral compression fracture: a meta-analysis and systematic review.
Wang B; Zhao CP; Song LX; Zhu L
J Orthop Surg Res; 2018 Oct; 13(1):264. PubMed ID: 30348192
[TBL] [Abstract][Full Text] [Related]
20. Therapeutic Efficacy and Safety of Percutaneous Curved Vertebroplasty in Osteoporotic Vertebral Compression Fractures: A Systematic Review and Meta-Analysis.
Sun Y; Zhang Y; Ma H; Tan M; Zhang Z
Orthop Surg; 2023 Oct; 15(10):2492-2504. PubMed ID: 37497571
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]