1. The performance of 11 fingertip pulse oximeters during hypoxemia in healthy human participants with varied, quantified skin pigment. Leeb G; Auchus I; Law T; Bickler P; Feiner J; Hashi S; Monk E; Igaga E; Bernstein M; Chou YC; Hughes C; Schornack D; Lester J; Moore K; Okunlola O; Fernandez J; Shmuylovich L; Lipnick M EBioMedicine; 2024 Apr; 102():105051. PubMed ID: 38458110 [TBL] [Abstract][Full Text] [Related]
2. Factors affecting the performance of 5 cerebral oximeters during hypoxia in healthy volunteers. Bickler PE; Feiner JR; Rollins MD Anesth Analg; 2013 Oct; 117(4):813-823. PubMed ID: 24023027 [TBL] [Abstract][Full Text] [Related]
3. Low Perfusion and Missed Diagnosis of Hypoxemia by Pulse Oximetry in Darkly Pigmented Skin: A Prospective Study. Gudelunas MK; Lipnick M; Hendrickson C; Vanderburg S; Okunlola B; Auchus I; Feiner JR; Bickler PE Anesth Analg; 2024 Mar; 138(3):552-561. PubMed ID: 38109495 [TBL] [Abstract][Full Text] [Related]
4. Skin Pigmentation and Pulse Oximeter Accuracy in the Intensive Care Unit: a Pilot Prospective Study. Fawzy A; Ali H; Dziedzic PH; Potu N; Calvillo E; Golden SH; Iwashyna TJ; Suarez JI; Hager DN; Garibaldi BT medRxiv; 2023 Nov; ():. PubMed ID: 38014046 [TBL] [Abstract][Full Text] [Related]
5. The Accuracy of 6 Inexpensive Pulse Oximeters Not Cleared by the Food and Drug Administration: The Possible Global Public Health Implications. Lipnick MS; Feiner JR; Au P; Bernstein M; Bickler PE Anesth Analg; 2016 Aug; 123(2):338-45. PubMed ID: 27089002 [TBL] [Abstract][Full Text] [Related]
6. Performance of a Wearable Ring in Controlled Hypoxia: A Prospective Observational Study. Mastrototaro JJ; Leabman M; Shumate J; Tompkins KL JMIR Form Res; 2024 Jun; 8():e54256. PubMed ID: 38838332 [TBL] [Abstract][Full Text] [Related]
7. Pulse Oximeter Performance, Racial Inequity, and the Work Ahead. Okunlola OE; Lipnick MS; Batchelder PB; Bernstein M; Feiner JR; Bickler PE Respir Care; 2022 Feb; 67(2):252-257. PubMed ID: 34772785 [TBL] [Abstract][Full Text] [Related]
8. Effects of skin pigmentation on pulse oximeter accuracy at low saturation. Bickler PE; Feiner JR; Severinghaus JW Anesthesiology; 2005 Apr; 102(4):715-9. PubMed ID: 15791098 [TBL] [Abstract][Full Text] [Related]
9. Perioperative comparison of the agreement between a portable fingertip pulse oximeter v. a conventional bedside pulse oximeter in adult patients (COMFORT trial). Smith RN; Hofmeyr R S Afr Med J; 2019 Feb; 109(3):154-158. PubMed ID: 30834870 [TBL] [Abstract][Full Text] [Related]
10. Changes in Oxygenation Levels During Moderate Altitude Simulation (Hypoxia-Induced): A Pilot Study Investigating the Impact of Skin Pigmentation in Pulse Oximetry. Ochoa-Gutierrez V; Guerrero-Zuñiga S; Reboud J; Pazmino-Betancourth M; Harvey AR; Cooper JM Adv Exp Med Biol; 2022; 1395():391-396. PubMed ID: 36527668 [TBL] [Abstract][Full Text] [Related]
11. The Accuracy of Readily Available Consumer-Grade Oxygen Saturation Monitors in Pediatric Patients. Kovesi T; Saban J; Haddad JF; Reddy D; Webster R; Udupa S Respir Care; 2024 Mar; 69(4):387-394. PubMed ID: 38164568 [TBL] [Abstract][Full Text] [Related]
12. Assessment of skin pigmentation-related bias in pulse oximetry readings among adults. Khanna AK; Beard J; Lamminmäki S; Närväinen J; Antaki N; Yapici HO J Clin Monit Comput; 2024 Feb; 38(1):113-120. PubMed ID: 37882880 [TBL] [Abstract][Full Text] [Related]
13. Four Types of Pulse Oximeters Accurately Detect Hypoxia during Low Perfusion and Motion. Louie A; Feiner JR; Bickler PE; Rhodes L; Bernstein M; Lucero J Anesthesiology; 2018 Mar; 128(3):520-530. PubMed ID: 29200008 [TBL] [Abstract][Full Text] [Related]
14. Impacts of Skin Color and Hypoxemia on Noninvasive Assessment of Peripheral Blood Oxygen Saturation: A Scoping Review. Aoki KC; Barrant M; Gai MJ; Handal M; Xu V; Mayrovitz HN Cureus; 2023 Sep; 15(9):e46078. PubMed ID: 37900526 [TBL] [Abstract][Full Text] [Related]
15. Accuracy of pulse oximeters in measuring oxygen saturation in patients with poor peripheral perfusion: a systematic review. Poorzargar K; Pham C; Ariaratnam J; Lee K; Parotto M; Englesakis M; Chung F; Nagappa M J Clin Monit Comput; 2022 Aug; 36(4):961-973. PubMed ID: 35119597 [TBL] [Abstract][Full Text] [Related]
16. The Use of Wearable Pulse Oximeters in the Prompt Detection of Hypoxemia and During Movement: Diagnostic Accuracy Study. Santos M; Vollam S; Pimentel MA; Areia C; Young L; Roman C; Ede J; Piper P; King E; Harford M; Shah A; Gustafson O; Tarassenko L; Watkinson P J Med Internet Res; 2022 Feb; 24(2):e28890. PubMed ID: 35166690 [TBL] [Abstract][Full Text] [Related]
17. A review of the effect of skin pigmentation on pulse oximeter accuracy. Al-Halawani R; Charlton PH; Qassem M; Kyriacou PA Physiol Meas; 2023 Jun; 44(5):. PubMed ID: 37172609 [No Abstract] [Full Text] [Related]
18. Accuracy of pulse oximetry in pigmented patients. Bothma PA; Joynt GM; Lipman J; Hon H; Mathala B; Scribante J; Kromberg J S Afr Med J; 1996 May; 86(5 Suppl):594-6. PubMed ID: 8914569 [TBL] [Abstract][Full Text] [Related]