These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

122 related articles for article (PubMed ID: 38461736)

  • 1. The ROSA robotic-arm system reliably restores joint line height, patella height and posterior condylar offset in total knee arthroplasty.
    Mayne AI; Rajgor H; Munasinghe C; Agrawal Y; Pagkalos J; Davis ET; Sharma AD
    Knee; 2024 Jun; 48():1-7. PubMed ID: 38461736
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Mako versus ROSA: comparing surgical accuracy in robotic total knee arthroplasty.
    Rajgor HD; Mayne A; Munasinghe C; Pagkalos J; Agrawal Y; Davis ET; Sharma AD
    J Robot Surg; 2024 Jan; 18(1):33. PubMed ID: 38231299
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Robotic-Arm Assisted Total Knee Arthroplasty More Accurately Restored the Posterior Condylar Offset Ratio and the Insall-Salvati Index Compared to the Manual Technique; A Cohort-Matched Study.
    Sultan AA; Samuel LT; Khlopas A; Sodhi N; Bhowmik-Stoker M; Chen A; Orozco F; Kolisek F; Mahoney O; Smith L; Malkani A; Molloy RM; Mont MA
    Surg Technol Int; 2019 May; 34():409-413. PubMed ID: 30742701
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Robotic-arm assisted total knee arthroplasty has a learning curve of seven cases for integration into the surgical workflow but no learning curve effect for accuracy of implant positioning.
    Kayani B; Konan S; Huq SS; Tahmassebi J; Haddad FS
    Knee Surg Sports Traumatol Arthrosc; 2019 Apr; 27(4):1132-1141. PubMed ID: 30225554
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Improved joint line and posterior offset restoration in primary total knee replacement using a robotic-assisted surgical technique: An international multi-centre retrospective analysis of matched cohorts.
    Popat R; Albelooshi A; Mahapatra P; Bollars P; Ettinger M; Jennings S; Van den Berg JL; Nathwani D
    PLoS One; 2022; 17(8):e0272722. PubMed ID: 36006969
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Clinical and radiological analysis of a personalized total knee arthroplasty system design.
    Benazzo F; Ghiara M; Rossi SMP; Pruneri E; Tiwari V; Perelli S
    Int Orthop; 2019 May; 43(5):1113-1121. PubMed ID: 30128671
    [TBL] [Abstract][Full Text] [Related]  

  • 7. The influence of patella height on soft tissue balance in cruciate-retaining and posterior-stabilised total knee arthroplasty.
    Nishizawa Y; Matsumoto T; Kubo S; Muratsu H; Matsushita T; Oka S; Ishida K; Matsuzaki T; Nishida K; Akisue T; Kuroda R; Kurosaka M
    Int Orthop; 2013 Mar; 37(3):421-5. PubMed ID: 23275081
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Pseudo-patella baja: a minor yet frequent complication of total knee arthroplasty.
    Bugelli G; Ascione F; Cazzella N; Franceschetti E; Franceschi F; Dell'Osso G; Svantesson E; Samuelsson K; Giannotti S
    Knee Surg Sports Traumatol Arthrosc; 2018 Jun; 26(6):1831-1837. PubMed ID: 29273898
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Robotic-assisted TKA leads to a better prosthesis alignment and a better joint line restoration as compared to conventional TKA: a prospective randomized controlled trial.
    Vaidya NV; Deshpande AN; Panjwani T; Patil R; Jaysingani T; Patil P
    Knee Surg Sports Traumatol Arthrosc; 2022 Feb; 30(2):621-626. PubMed ID: 33165631
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Differences in joint line level and posterior condylar offset during total knee replacement with use of gap-balancing and measured resection techniques-matched cohort study.
    Maciąg BM; Kordyaczny T; Jegierski D; Łapiński M; Dorocińska M; Żarnovsky K; Maciąg GJ; Adamska O; Stolarczyk A
    BMC Musculoskelet Disord; 2023 Jul; 24(1):610. PubMed ID: 37491199
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Association Between Femoral Component Sagittal Positioning and Anterior Knee Pain in Total Knee Arthroplasty: A 10-Year Case-Control Follow-up Study of a Cruciate-Retaining Single-Radius Design.
    Scott CEH; Clement ND; Yapp LZ; MacDonald DJ; Patton JT; Burnett R
    J Bone Joint Surg Am; 2019 Sep; 101(17):1575-1585. PubMed ID: 31483401
    [TBL] [Abstract][Full Text] [Related]  

  • 12. How does the use of quantified gap-balancing affect component positioning and limb alignment in robotic total knee arthroplasty using functional alignment philosophy? A comparison of two robotic platforms.
    Murphy GT; Shatrov J; Duong J; Fritsch BA
    Int Orthop; 2023 May; 47(5):1221-1232. PubMed ID: 36740610
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Enhancing robotic precision in medial UKA: Image-based robot-assisted system had higher accuracy in implant positioning than imageless robot-assisted system across 292 knees.
    Gaggiotti S; Foissey C; Pineda T; Batailler C; Gaggiotti G; Gaggiotti S; Servien E; Lustig S
    Knee Surg Sports Traumatol Arthrosc; 2024 Aug; 32(8):2097-2106. PubMed ID: 38690988
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Image-free handheld robotic-assisted technology improved the accuracy of implant positioning compared to conventional instrumentation in patients undergoing simultaneous bilateral total knee arthroplasty, without additional benefits in improvement of clinical outcomes.
    Albelooshi A; Hamie M; Bollars P; Althani S; Salameh R; Almasri M; Schotanus MGM; Meshram P
    Knee Surg Sports Traumatol Arthrosc; 2023 Nov; 31(11):4833-4841. PubMed ID: 37558748
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Does Robotic-assisted TKA Result in Better Outcome Scores or Long-Term Survivorship Than Conventional TKA? A Randomized, Controlled Trial.
    Kim YH; Yoon SH; Park JW
    Clin Orthop Relat Res; 2020 Feb; 478(2):266-275. PubMed ID: 31389889
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Computer guided restoration of joint line and femoral offset in cruciate substituting total knee arthroplasty.
    Shetty GM; Mullaji A; Bhayde S
    Knee; 2012 Oct; 19(5):611-6. PubMed ID: 22178624
    [TBL] [Abstract][Full Text] [Related]  

  • 17. The influence of patella height on intra-operative soft tissue balance in posterior-stabilized total knee arthroplasty.
    Sasaki H; Kubo S; Matsumoto T; Muratsu H; Matsushita T; Ishida K; Takayama K; Oka S; Kurosaka M; Kuroda R
    Knee Surg Sports Traumatol Arthrosc; 2012 Nov; 20(11):2191-6. PubMed ID: 22120839
    [TBL] [Abstract][Full Text] [Related]  

  • 18. The John Insall Award: control-matched evaluation of painful patellar Crepitus after total knee arthroplasty.
    Dennis DA; Kim RH; Johnson DR; Springer BD; Fehring TK; Sharma A
    Clin Orthop Relat Res; 2011 Jan; 469(1):10-7. PubMed ID: 20706813
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Kinematic aligned femoral rotation leads to greater patella tilt but similar clinical outcomes when compared to traditional femoral component rotation in total knee arthroplasty. A propensity score matched study.
    Koh DTS; Woo YL; Yew AKS; Yeo SJ
    Knee Surg Sports Traumatol Arthrosc; 2021 Apr; 29(4):1059-1066. PubMed ID: 32488370
    [TBL] [Abstract][Full Text] [Related]  

  • 20. The effect of femoral component design on patellar tracking in total knee arthroplasty: Genesis II prosthesis versus Vanguard prosthesis.
    Kong CG; Park SW; Yang H; In Y
    Arch Orthop Trauma Surg; 2014 Apr; 134(4):571-6. PubMed ID: 24515865
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.