These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
150 related articles for article (PubMed ID: 38477107)
41. Kinematic aligned femoral rotation leads to greater patella tilt but similar clinical outcomes when compared to traditional femoral component rotation in total knee arthroplasty. A propensity score matched study. Koh DTS; Woo YL; Yew AKS; Yeo SJ Knee Surg Sports Traumatol Arthrosc; 2021 Apr; 29(4):1059-1066. PubMed ID: 32488370 [TBL] [Abstract][Full Text] [Related]
42. [Clinical results of medial mobile bearing unicompartmental knee arthroplasty using kinematic alignment technique with at least 5-years follow-up]. Zhang QD; Huang C; Sun XW; Ding R; Wang WG; Cheng LM; Liu ZH; Guo WS Zhonghua Yi Xue Za Zhi; 2023 Jan; 103(1):18-24. PubMed ID: 36594133 [No Abstract] [Full Text] [Related]
43. Customised, individually made total knee arthroplasty shows promising 1-year clinical and patient reported outcomes. Moret CS; Hirschmann MT; Vogel N; Arnold MP Arch Orthop Trauma Surg; 2021 Dec; 141(12):2217-2225. PubMed ID: 34269890 [TBL] [Abstract][Full Text] [Related]
44. Perioperative varus alignment does not affect short-term patient-reported outcome measures following mobile-bearing unicompartmental knee arthroplasty. Itou J; Kuwashima U; Itoh M; Okazaki K J Orthop Surg Res; 2022 Feb; 17(1):98. PubMed ID: 35168658 [TBL] [Abstract][Full Text] [Related]
45. The ability to kneel before and after total knee arthroplasty : the role of the pattern of osteoarthritis and the position of the femoral component. Scott CEH; Holland G; Gillespie M; Keenan OJ; Gherman A; MacDonald DJ; Simpson AHRW; Clement ND Bone Joint J; 2021 Sep; 103-B(9):1514-1525. PubMed ID: 34465156 [TBL] [Abstract][Full Text] [Related]
46. Stability and alignment do not improve by using patient-specific instrumentation in total knee arthroplasty: a randomized controlled trial. Kosse NM; Heesterbeek PJC; Schimmel JJP; van Hellemondt GG; Wymenga AB; Defoort KC Knee Surg Sports Traumatol Arthrosc; 2018 Jun; 26(6):1792-1799. PubMed ID: 29181560 [TBL] [Abstract][Full Text] [Related]
48. Prosthetic alignment after total knee replacement is not associated with dissatisfaction or change in Oxford Knee Score: A multivariable regression analysis. Huijbregts HJ; Khan RJ; Fick DP; Jarrett OM; Haebich S Knee; 2016 Jun; 23(3):535-9. PubMed ID: 26826945 [TBL] [Abstract][Full Text] [Related]
50. Which Asymmetric Tibial Component Is Optimally Designed for Calipered Kinematically Aligned Total Knee Arthroplasty? Nedopil AJ; Zamora T; Delman C; Howell SM; Hull ML J Knee Surg; 2022 Dec; 35(14):1610-1618. PubMed ID: 33932950 [TBL] [Abstract][Full Text] [Related]
51. Is There a Force Target That Predicts Early Patient-reported Outcomes After Kinematically Aligned TKA? Shelton TJ; Howell SM; Hull ML Clin Orthop Relat Res; 2019 May; 477(5):1200-1207. PubMed ID: 30531423 [TBL] [Abstract][Full Text] [Related]
52. Alignment strategy for different types of varus knee with generic instruments: Mechanical alignment or kinematic alignment? Lin H; Cheng Q; Li G; Zhao J; Wang Q J Orthop Surg Res; 2023 Oct; 18(1):806. PubMed ID: 37898810 [TBL] [Abstract][Full Text] [Related]
53. Patient-Specific Simulated Dynamics After Total Knee Arthroplasty Correlate With Patient-Reported Outcomes. Twiggs JG; Wakelin EA; Roe JP; Dickison DM; Fritsch BA; Miles BP; Ruys AJ J Arthroplasty; 2018 Sep; 33(9):2843-2850. PubMed ID: 29807792 [TBL] [Abstract][Full Text] [Related]
54. Targeting the neutral hip-to-calcaneus axis in kinematically aligned total knee arthroplasty is feasible with fewer alignment outliers for varus osteoarthritic patients. Matsumoto T; Nakano N; Ishida K; Maeda T; Tachibana S; Kuroda Y; Hayashi S; Matsushita T; Kuroda R Knee Surg Sports Traumatol Arthrosc; 2023 Sep; 31(9):3880-3888. PubMed ID: 36918435 [TBL] [Abstract][Full Text] [Related]
55. Three-year clinical and radiological results of a cruciate-retaining type of the knee prosthesis with anatomical geometry developed in Japan. Nakajima A; Yamada M; Sonobe M; Akatsu Y; Saito M; Yamamoto K; Saito J; Norimoto M; Koyama K; Takahashi H; Aoki Y; Suguro T; Nakagawa K BMC Musculoskelet Disord; 2021 Mar; 22(1):241. PubMed ID: 33658001 [TBL] [Abstract][Full Text] [Related]
56. Arithmetic hip-knee-ankle angle (aHKA): An algorithm for estimating constitutional lower limb alignment in the arthritic patient population. Griffiths-Jones W; Chen DB; Harris IA; Bellemans J; MacDessi SJ Bone Jt Open; 2021 May; 2(5):351-358. PubMed ID: 34042492 [TBL] [Abstract][Full Text] [Related]
57. What is the "safe zone" for transition of coronal alignment from systematic to a more personalised one in total knee arthroplasty? A systematic review. Schelker BL; Nowakowski AM; Hirschmann MT Knee Surg Sports Traumatol Arthrosc; 2022 Feb; 30(2):419-427. PubMed ID: 34973095 [TBL] [Abstract][Full Text] [Related]
58. Effect of polyethylene conformity on total knee arthroplasty early clinical outcomes. Indelli PF; Risitano S; Hall KE; Leonardi E; Migliore E Knee Surg Sports Traumatol Arthrosc; 2019 Apr; 27(4):1028-1034. PubMed ID: 30328496 [TBL] [Abstract][Full Text] [Related]
59. Coronal Plane Alignment of the Knee (CPAK) classification. MacDessi SJ; Griffiths-Jones W; Harris IA; Bellemans J; Chen DB Bone Joint J; 2021 Feb; 103-B(2):329-337. PubMed ID: 33517740 [TBL] [Abstract][Full Text] [Related]
60. Association Between Femoral Component Sagittal Positioning and Anterior Knee Pain in Total Knee Arthroplasty: A 10-Year Case-Control Follow-up Study of a Cruciate-Retaining Single-Radius Design. Scott CEH; Clement ND; Yapp LZ; MacDonald DJ; Patton JT; Burnett R J Bone Joint Surg Am; 2019 Sep; 101(17):1575-1585. PubMed ID: 31483401 [TBL] [Abstract][Full Text] [Related] [Previous] [Next] [New Search]