BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

131 related articles for article (PubMed ID: 38493231)

  • 1. Study on the characteristics of increased mechanical stiffness according to changes in LCP shape to reinforce clavicle fractures.
    Kim SM; Kim ST; Han DW; Kim DG
    Sci Rep; 2024 Mar; 14(1):6382. PubMed ID: 38493231
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Numerical simulation and biomechanical analysis of locking screw caps on clavicle locking plates.
    Kim DG; Min Kim S; Kim Y
    Medicine (Baltimore); 2022 Jul; 101(30):e29319. PubMed ID: 35905263
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Biomechanical comparison of the Locking Compression superior anterior clavicle plate with seven and ten hole reconstruction plates in midshaft clavicle fracture stabilisation.
    Eden L; Doht S; Frey SP; Ziegler D; Stoyhe J; Fehske K; Blunk T; Meffert RH
    Int Orthop; 2012 Dec; 36(12):2537-43. PubMed ID: 23073924
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Biomechanical and clinical evaluation of minimal invasive plate osteosynthesis for two-part clavicle shaft fractures.
    Schlüßler A; Fehrenbacher M; Richter RF; Tille E; Biewener A; Nowotny J
    BMC Musculoskelet Disord; 2023 Jul; 24(1):612. PubMed ID: 37491249
    [TBL] [Abstract][Full Text] [Related]  

  • 5. The application of inverted lateral clavicle locking compression plate for medial clavicle fractures: biomechanical study and clinical implementation.
    Kritsaneephaiboon A; Jitprapaikulsarn S; Chantarapanich N; Klabklay P; Gromprasit A; Patamamongkonchai C; Dissaneewate P
    Eur J Orthop Surg Traumatol; 2024 Apr; 34(3):1465-1478. PubMed ID: 38245617
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Comparative analysis of a locking plate with an all-suture anchor versus hook plate fixation of Neer IIb distal clavicle fractures.
    Seo JB; Kwak KY; Yoo JS
    J Orthop Surg (Hong Kong); 2020; 28(3):2309499020962260. PubMed ID: 33118439
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Finite element analysis comparison between superior clavicle locking plate with and without screw holes above fracture zone in midshaft clavicular fracture.
    Pengrung N; Lakdee N; Puncreobutr C; Lohwongwatana B; Sa-Ngasoongsong P
    BMC Musculoskelet Disord; 2019 Oct; 20(1):465. PubMed ID: 31640668
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Comparison of a novel hybrid hook locking plate fixation method with the conventional AO hook plate fixation method for Neer type V distal clavicle fractures.
    Seo J; Heo K; Kim SJ; Kim JK; Ham HJ; Yoo J
    Orthop Traumatol Surg Res; 2020 Feb; 106(1):67-75. PubMed ID: 31826826
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Unicortical versus bicortical locked plate fixation in midshaft clavicle fractures.
    Bravman JT; Taylor ML; Baldini T; Vidal AF
    Orthopedics; 2015 May; 38(5):e411-6. PubMed ID: 25970369
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Biomechanical Analysis of Superior and Anterior Precontoured Plate Fixation Techniques for Neer Type II-A Clavicle Fractures.
    Worhacz K; Nayak AN; Boudreaux RL; Pavan B; Wipf Dipl-Ing F; Jacofsky MC; Araghi A
    J Orthop Trauma; 2018 Dec; 32(12):e462-e468. PubMed ID: 30252778
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Finite element analysis of dual small plate fixation and single plate fixation for treatment of midshaft clavicle fractures.
    Zhang F; Chen F; Qi Y; Qian Z; Ni S; Zhong Z; Zhang X; Li D; Yu B
    J Orthop Surg Res; 2020 Apr; 15(1):148. PubMed ID: 32295608
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Operative treatment of clavicle midshaft fractures: comparison between reconstruction plate and reconstruction locking compression plate.
    Cho CH; Song KS; Min BW; Bae KC; Lee KJ
    Clin Orthop Surg; 2010 Sep; 2(3):154-9. PubMed ID: 20808586
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Two reconstruction plates provide superior stability of displaced midshaft clavicle fractures in comparison to single plating - A biomechanical study.
    Yanev P; Zderic I; Pukalski Y; Enchev D; Rashkov M; Varga P; Gehweiler D; Richards G; Gueorguiev B; Baltov A
    Clin Biomech (Bristol, Avon); 2020 Dec; 80():105199. PubMed ID: 33129563
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Canceling Notch Improves the Mechanical Safety of Clavicle Locking Plate: A 3D Finite Element Study.
    Han Z; Luo Q; Deng G; Bi C; Yin G; Lin H; Wu J; Wu X
    Orthop Surg; 2023 Aug; 15(8):2152-2156. PubMed ID: 36349872
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Biomechanical Comparison of Locking Plate and Cancellous Screw Techniques in Medial Malleolar Fractures: A Finite Element Analysis.
    Jiang D; Zhan S; Wang Q; Ling M; Hu H; Jia W
    J Foot Ankle Surg; 2019 Nov; 58(6):1138-1144. PubMed ID: 31562067
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Conceptual finite element study for comparison among superior, anterior, and spiral clavicle plate fixations for midshaft clavicle fracture.
    Huang TL; Chen WC; Lin KJ; Tsai CL; Lin KP; Wei HW
    Med Eng Phys; 2016 Oct; 38(10):1070-5. PubMed ID: 27423702
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Comparing the locking screw direction of three locking plates for lateral clavicle fractures: a simulation study.
    Abe S; Koizumi K; Murase T; Kuriyama K
    BMC Musculoskelet Disord; 2021 Sep; 22(1):812. PubMed ID: 34548051
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Unicortical and bicortical plating in the fixation of comminuted fractures of the clavicle: a biomechanical study.
    Looft JM; Corrêa L; Patel M; Rawlings M; Ackland DC
    ANZ J Surg; 2017 Nov; 87(11):915-920. PubMed ID: 28922701
    [TBL] [Abstract][Full Text] [Related]  

  • 19. A comparison of conventional compression plates and locking compression plates using cantilever bending in an ilial fracture model.
    Bruce CW; Gibson TW; Runciman RJ
    Vet Comp Orthop Traumatol; 2014; 27(6):430-5. PubMed ID: 25345445
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Bioabsorbable plating in the treatment of pediatric clavicle fractures: A biomechanical and clinical analysis.
    Osborn EJ; Farnsworth CL; Doan JD; Edmonds EW
    Clin Biomech (Bristol, Avon); 2018 Jun; 55():94-99. PubMed ID: 29727767
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.