131 related articles for article (PubMed ID: 38493231)
1. Study on the characteristics of increased mechanical stiffness according to changes in LCP shape to reinforce clavicle fractures.
Kim SM; Kim ST; Han DW; Kim DG
Sci Rep; 2024 Mar; 14(1):6382. PubMed ID: 38493231
[TBL] [Abstract][Full Text] [Related]
2. Numerical simulation and biomechanical analysis of locking screw caps on clavicle locking plates.
Kim DG; Min Kim S; Kim Y
Medicine (Baltimore); 2022 Jul; 101(30):e29319. PubMed ID: 35905263
[TBL] [Abstract][Full Text] [Related]
3. Biomechanical comparison of the Locking Compression superior anterior clavicle plate with seven and ten hole reconstruction plates in midshaft clavicle fracture stabilisation.
Eden L; Doht S; Frey SP; Ziegler D; Stoyhe J; Fehske K; Blunk T; Meffert RH
Int Orthop; 2012 Dec; 36(12):2537-43. PubMed ID: 23073924
[TBL] [Abstract][Full Text] [Related]
4. Biomechanical and clinical evaluation of minimal invasive plate osteosynthesis for two-part clavicle shaft fractures.
Schlüßler A; Fehrenbacher M; Richter RF; Tille E; Biewener A; Nowotny J
BMC Musculoskelet Disord; 2023 Jul; 24(1):612. PubMed ID: 37491249
[TBL] [Abstract][Full Text] [Related]
5. The application of inverted lateral clavicle locking compression plate for medial clavicle fractures: biomechanical study and clinical implementation.
Kritsaneephaiboon A; Jitprapaikulsarn S; Chantarapanich N; Klabklay P; Gromprasit A; Patamamongkonchai C; Dissaneewate P
Eur J Orthop Surg Traumatol; 2024 Apr; 34(3):1465-1478. PubMed ID: 38245617
[TBL] [Abstract][Full Text] [Related]
6. Comparative analysis of a locking plate with an all-suture anchor versus hook plate fixation of Neer IIb distal clavicle fractures.
Seo JB; Kwak KY; Yoo JS
J Orthop Surg (Hong Kong); 2020; 28(3):2309499020962260. PubMed ID: 33118439
[TBL] [Abstract][Full Text] [Related]
7. Finite element analysis comparison between superior clavicle locking plate with and without screw holes above fracture zone in midshaft clavicular fracture.
Pengrung N; Lakdee N; Puncreobutr C; Lohwongwatana B; Sa-Ngasoongsong P
BMC Musculoskelet Disord; 2019 Oct; 20(1):465. PubMed ID: 31640668
[TBL] [Abstract][Full Text] [Related]
8. Comparison of a novel hybrid hook locking plate fixation method with the conventional AO hook plate fixation method for Neer type V distal clavicle fractures.
Seo J; Heo K; Kim SJ; Kim JK; Ham HJ; Yoo J
Orthop Traumatol Surg Res; 2020 Feb; 106(1):67-75. PubMed ID: 31826826
[TBL] [Abstract][Full Text] [Related]
9. Unicortical versus bicortical locked plate fixation in midshaft clavicle fractures.
Bravman JT; Taylor ML; Baldini T; Vidal AF
Orthopedics; 2015 May; 38(5):e411-6. PubMed ID: 25970369
[TBL] [Abstract][Full Text] [Related]
10. Biomechanical Analysis of Superior and Anterior Precontoured Plate Fixation Techniques for Neer Type II-A Clavicle Fractures.
Worhacz K; Nayak AN; Boudreaux RL; Pavan B; Wipf Dipl-Ing F; Jacofsky MC; Araghi A
J Orthop Trauma; 2018 Dec; 32(12):e462-e468. PubMed ID: 30252778
[TBL] [Abstract][Full Text] [Related]
11. Finite element analysis of dual small plate fixation and single plate fixation for treatment of midshaft clavicle fractures.
Zhang F; Chen F; Qi Y; Qian Z; Ni S; Zhong Z; Zhang X; Li D; Yu B
J Orthop Surg Res; 2020 Apr; 15(1):148. PubMed ID: 32295608
[TBL] [Abstract][Full Text] [Related]
12. Operative treatment of clavicle midshaft fractures: comparison between reconstruction plate and reconstruction locking compression plate.
Cho CH; Song KS; Min BW; Bae KC; Lee KJ
Clin Orthop Surg; 2010 Sep; 2(3):154-9. PubMed ID: 20808586
[TBL] [Abstract][Full Text] [Related]
13. Two reconstruction plates provide superior stability of displaced midshaft clavicle fractures in comparison to single plating - A biomechanical study.
Yanev P; Zderic I; Pukalski Y; Enchev D; Rashkov M; Varga P; Gehweiler D; Richards G; Gueorguiev B; Baltov A
Clin Biomech (Bristol, Avon); 2020 Dec; 80():105199. PubMed ID: 33129563
[TBL] [Abstract][Full Text] [Related]
14. Canceling Notch Improves the Mechanical Safety of Clavicle Locking Plate: A 3D Finite Element Study.
Han Z; Luo Q; Deng G; Bi C; Yin G; Lin H; Wu J; Wu X
Orthop Surg; 2023 Aug; 15(8):2152-2156. PubMed ID: 36349872
[TBL] [Abstract][Full Text] [Related]
15. Biomechanical Comparison of Locking Plate and Cancellous Screw Techniques in Medial Malleolar Fractures: A Finite Element Analysis.
Jiang D; Zhan S; Wang Q; Ling M; Hu H; Jia W
J Foot Ankle Surg; 2019 Nov; 58(6):1138-1144. PubMed ID: 31562067
[TBL] [Abstract][Full Text] [Related]
16. Conceptual finite element study for comparison among superior, anterior, and spiral clavicle plate fixations for midshaft clavicle fracture.
Huang TL; Chen WC; Lin KJ; Tsai CL; Lin KP; Wei HW
Med Eng Phys; 2016 Oct; 38(10):1070-5. PubMed ID: 27423702
[TBL] [Abstract][Full Text] [Related]
17. Comparing the locking screw direction of three locking plates for lateral clavicle fractures: a simulation study.
Abe S; Koizumi K; Murase T; Kuriyama K
BMC Musculoskelet Disord; 2021 Sep; 22(1):812. PubMed ID: 34548051
[TBL] [Abstract][Full Text] [Related]
18. Unicortical and bicortical plating in the fixation of comminuted fractures of the clavicle: a biomechanical study.
Looft JM; Corrêa L; Patel M; Rawlings M; Ackland DC
ANZ J Surg; 2017 Nov; 87(11):915-920. PubMed ID: 28922701
[TBL] [Abstract][Full Text] [Related]
19. A comparison of conventional compression plates and locking compression plates using cantilever bending in an ilial fracture model.
Bruce CW; Gibson TW; Runciman RJ
Vet Comp Orthop Traumatol; 2014; 27(6):430-5. PubMed ID: 25345445
[TBL] [Abstract][Full Text] [Related]
20. Bioabsorbable plating in the treatment of pediatric clavicle fractures: A biomechanical and clinical analysis.
Osborn EJ; Farnsworth CL; Doan JD; Edmonds EW
Clin Biomech (Bristol, Avon); 2018 Jun; 55():94-99. PubMed ID: 29727767
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]