These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

181 related articles for article (PubMed ID: 38497138)

  • 1. Flap blood glucose measurement for flap monitoring and early detection of circulatory problems.
    Anwar MH; Dwivedi R; Singh B; Agarwal V; Agarwal P; Sharma D
    Trop Doct; 2024 Jul; 54(3):248-250. PubMed ID: 38497138
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Blood glucose measurement for flap monitoring to salvage flaps from venous thrombosis.
    Hara H; Mihara M; Iida T; Narushima M; Todokoro T; Yamamoto T; Koshima I
    J Plast Reconstr Aesthet Surg; 2012 May; 65(5):616-9. PubMed ID: 22153849
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Blood glucose measurement in flap monitoring for salvage of flaps from venous thrombosis.
    Hara H; Mihara M; Iida T; Narushima M; Koshima I
    Plast Reconstr Surg; 2012 Mar; 129(3):587e-589e. PubMed ID: 22374034
    [No Abstract]   [Full Text] [Related]  

  • 4. Diagnostic Accuracy of Blood Glucose Measurements in Detecting Venous Compromise in Flaps.
    Bashir MM; Tayyab Z; Afzal S; Khan FA
    J Craniofac Surg; 2015 Jul; 26(5):1492-4. PubMed ID: 26114526
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Timing of presentation of the first signs of vascular compromise dictates the salvage outcome of free flap transfers.
    Chen KT; Mardini S; Chuang DC; Lin CH; Cheng MH; Lin YT; Huang WC; Tsao CK; Wei FC
    Plast Reconstr Surg; 2007 Jul; 120(1):187-195. PubMed ID: 17572562
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Implantable venous Doppler monitoring in head and neck free flap reconstruction increases the salvage rate.
    Paydar KZ; Hansen SL; Chang DS; Hoffman WY; Leon P
    Plast Reconstr Surg; 2010 Apr; 125(4):1129-1134. PubMed ID: 20335864
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Flap Blood Glucose as a Sensitive and Specific Indicator for Flap Venous Congestion: A Rodent Model Study.
    Mochizuki K; Mochizuki M; Gonda K
    Plast Reconstr Surg; 2019 Sep; 144(3):409e-418e. PubMed ID: 31461018
    [TBL] [Abstract][Full Text] [Related]  

  • 8. [Monitoring free flaps with cutaneous microdialysis: preliminary study in oral cavity reconstruction].
    Brix M; Muret P; Ricbourg B; Humbert P
    Rev Stomatol Chir Maxillofac; 2006 Dec; 107(6):460-4. PubMed ID: 17195000
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Transcutaneous oxygen measurement using ratiometric fluorescence imaging as a valid method for monitoring free flap transplants.
    Schiltz D; Taeger CD; Biermann N; Ranieri M; Klein S; Prantl L; Geis S
    Clin Hemorheol Microcirc; 2019; 73(1):113-123. PubMed ID: 31561353
    [TBL] [Abstract][Full Text] [Related]  

  • 10. A simplest method of flap monitoring.
    Sakakibara S; Hashikawa K; Omori M; Terashi H; Tahara S
    J Reconstr Microsurg; 2010 Sep; 26(7):433-4. PubMed ID: 20336602
    [No Abstract]   [Full Text] [Related]  

  • 11. Suprastomal cutaneous monitoring paddle for free flap reconstruction of laryngopharyngectomy defects.
    Revenaugh PC; Waters HH; Scharpf J; Knott PD; Fritz MA
    JAMA Facial Plast Surg; 2013; 15(4):287-91. PubMed ID: 23598743
    [TBL] [Abstract][Full Text] [Related]  

  • 12. [Microdialysis: experience in postoperative monitoring of 30 free flaps].
    Laure B; Sury F; Bayol JC; Goga D
    Ann Chir Plast Esthet; 2009 Feb; 54(1):29-36. PubMed ID: 19042067
    [TBL] [Abstract][Full Text] [Related]  

  • 13. An evolution of communication in postoperative free flap monitoring: using a smartphone and mobile messenger application.
    Hee Hwang J; Mun GH
    Plast Reconstr Surg; 2012 Jul; 130(1):125-129. PubMed ID: 22743879
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Are there risk factors for complications of perforator-based propeller flaps for lower-extremity reconstruction?
    Innocenti M; Menichini G; Baldrighi C; Delcroix L; Vignini L; Tos P
    Clin Orthop Relat Res; 2014 Jul; 472(7):2276-86. PubMed ID: 24706021
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Continuous postoperative monitoring of cutaneous free flaps using near infrared spectroscopy.
    Repez A; Oroszy D; Arnez ZM
    J Plast Reconstr Aesthet Surg; 2008; 61(1):71-7. PubMed ID: 17532278
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Coverage of exposed hardware after lower leg fractures with free flaps or pedicled flaps.
    Fallico N; Somma F; Cigna E; Dessy LA; Tarallo M; Ribuffo D
    Eur Rev Med Pharmacol Sci; 2015 Dec; 19(24):4715-21. PubMed ID: 26744862
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Effectiveness of small monitoring skin paddle in free muscle flap for scalp reconstruction.
    Park SO; Son Y; Kim IK; Jin US; Chang H
    Head Neck; 2018 Nov; 40(11):2399-2408. PubMed ID: 30175898
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Free flap monitoring using simultaneous non-invasive laser Doppler flowmetry and tissue spectrophotometry.
    Hölzle F; Loeffelbein DJ; Nolte D; Wolff KD
    J Craniomaxillofac Surg; 2006 Jan; 34(1):25-33. PubMed ID: 16343915
    [TBL] [Abstract][Full Text] [Related]  

  • 19. [Clinical applications of the neurocutaneous axial flap pedicled with perforating vessels].
    Chai YM; Lin CZ; Qiu XY; Chen HD; Wang KS; Chen YK
    Zhonghua Zheng Xing Wai Ke Za Zhi; 2006 Jan; 22(1):34-7. PubMed ID: 16573162
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Using blood glucose and lactate levels for early detection of venous congestion following a free flap procedure for lower extremity open fractures.
    Kobayashi Y; Uchiyama Y; Ishii T; Nakajima D; Yanagisawa S; Saito I; Watanabe M
    Eur J Trauma Emerg Surg; 2022 Jun; 48(3):2493-2501. PubMed ID: 34807271
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 10.