125 related articles for article (PubMed ID: 38502722)
1. Transcatheter Patent Ductus Arteriosus Closure in Premature Infants: A Multicenter Retrospective Study Comparing Available Devices.
Dalby ST; Shibbani K; Mercadante A; Veeram Reddy SR; Aldoss O; Gordon BM; El-Said H; Mohammad Nijres B
Circ Cardiovasc Interv; 2024 Mar; 17(3):e013723. PubMed ID: 38502722
[No Abstract] [Full Text] [Related]
2. Transcatheter closure of hemodynamic significant patent ductus arteriosus in 32 premature infants by amplatzer ductal occluder additional size-ADOIIAS.
Morville P; Akhavi A
Catheter Cardiovasc Interv; 2017 Oct; 90(4):612-617. PubMed ID: 28471089
[TBL] [Abstract][Full Text] [Related]
3. Transcatheter closure of tubular patent ductus arteriosus using muscular ventricular septal defect devices in infants and small children with congestive heart failure.
Salam A; Bautista-Rodriguez C; Karsenty C; Bouvaist H; Piccinelli E; Fraisse A
Arch Cardiovasc Dis; 2022 Mar; 115(3):134-141. PubMed ID: 35249850
[TBL] [Abstract][Full Text] [Related]
4. Transcatheter patent ductus arteriosus closure in preterm infants: Appropriate device selection is primordial.
Baruteau AE; Fraisse A
Int J Cardiol; 2020 Oct; 316():108-109. PubMed ID: 32891262
[No Abstract] [Full Text] [Related]
5. Reply to the letter: Transcatheter patent ductus arteriosus closure in preterm infants: Appropriate device selection is primordial.
Chien YH; Chen CA
Int J Cardiol; 2020 Oct; 316():107. PubMed ID: 32891261
[No Abstract] [Full Text] [Related]
6. Percutaneous closure of a large patent ductus arteriosus in a preterm newborn weighing 1400 g without using arterial sheath: an innovative technique.
Garg G; Garg V; Prakash A
Cardiol Young; 2018 Mar; 28(3):494-497. PubMed ID: 29233212
[TBL] [Abstract][Full Text] [Related]
7. Patent Ductus Arteriosus closure in preterms less than 2kg: Surgery versus transcatheter.
Pamukcu O; Tuncay A; Narin N; Baykan A; Korkmaz L; Argun M; Ozyurt A; Sunkak S; Uzum K
Int J Cardiol; 2018 Jan; 250():110-115. PubMed ID: 29017778
[TBL] [Abstract][Full Text] [Related]
8. Small and preterm infants: The shrinking frontier of transcatheter patent ductus arteriosus closure.
McElhinney DB
Catheter Cardiovasc Interv; 2017 May; 89(6):1066-1068. PubMed ID: 28432825
[No Abstract] [Full Text] [Related]
9. Incidence and fate of device-related left pulmonary artery stenosis and aortic coarctation in small infants undergoing transcatheter patent ductus arteriosus closure.
Tomasulo CE; Gillespie MJ; Munson D; Demkin T; O'Byrne ML; Dori Y; Smith CL; Rome JJ; Glatz AC
Catheter Cardiovasc Interv; 2020 Oct; 96(4):889-897. PubMed ID: 32339400
[TBL] [Abstract][Full Text] [Related]
10. Transcatheter occlusion of the patent ductus arteriosus in premature infants weighing less than 1200 g.
Morville P; Douchin S; Bouvaist H; Dauphin C
Arch Dis Child Fetal Neonatal Ed; 2018 May; 103(3):F198-F201. PubMed ID: 29066474
[TBL] [Abstract][Full Text] [Related]
11. Device deformation and left pulmonary artery obstruction after transcatheter patent ductus arteriosus closure in preterm infants.
Chien YH; Wang HH; Lin MT; Lin HC; Lu CW; Chiu SN; Wu MH; Wang JK; Chen CA
Int J Cardiol; 2020 Aug; 312():50-55. PubMed ID: 32143922
[TBL] [Abstract][Full Text] [Related]
12. Closure of patent ductus arteriosus in children, small infants, and premature babies with Amplatzer duct occluder II additional sizes: multicenter study.
Sungur M; Karakurt C; Ozbarlas N; Baspinar O
Catheter Cardiovasc Interv; 2013 Aug; 82(2):245-52. PubMed ID: 23460349
[TBL] [Abstract][Full Text] [Related]
13. Late manifestation coarctation of the aorta in a premature infant 4-month post-percutaneous device closure of a patent ductus arteriosus.
Serrano RM; Rodefeld MD; Alexy R
Cardiol Young; 2019 Dec; 29(12):1556-1558. PubMed ID: 31760959
[TBL] [Abstract][Full Text] [Related]
14. Amplatzer Piccolo Occluder clinical trial for percutaneous closure of the patent ductus arteriosus in patients ≥700 grams.
Sathanandam SK; Gutfinger D; O'Brien L; Forbes TJ; Gillespie MJ; Berman DP; Armstrong AK; Shahanavaz S; Jones TK; Morray BH; Rockefeller TA; Justino H; Nykanen DG; Zahn EM
Catheter Cardiovasc Interv; 2020 Nov; 96(6):1266-1276. PubMed ID: 32433821
[TBL] [Abstract][Full Text] [Related]
15. Transjugular venous approach for Piccolo patent ductus arteriosus closure in a 1.4 kg infant.
Herron C; Forbes TJ; Kobayashi D
Cardiol Young; 2022 Jan; 32(1):111-112. PubMed ID: 34865669
[TBL] [Abstract][Full Text] [Related]
16. Transcatheter patent arterial duct closure in premature infants: A new technique to ease access to the patent arterial duct, with particular benefit for the tricuspid valve.
Meot M; Gaudin R; Szezepanski I; Bajolle F; Bonnet D; Malekzadeh-Milani S
Arch Cardiovasc Dis; 2021; 114(6-7):482-489. PubMed ID: 34312100
[TBL] [Abstract][Full Text] [Related]
17. Transcatheter closure of a patent ductus arteriosus in a preterm infant with an Amplatzer Vascular Plug IV device.
Prsa M; Ewert P
Catheter Cardiovasc Interv; 2011 Jan; 77(1):108-11. PubMed ID: 20517997
[TBL] [Abstract][Full Text] [Related]
18. Outcomes of transcatheter occlusion of patent ductus arteriosus in infants weighing ≤ 6 kg.
Dimas VV; Takao C; Ing FF; Mattamal R; Nugent AW; Grifka RG; Mullins CE; Justino H
JACC Cardiovasc Interv; 2010 Dec; 3(12):1295-9. PubMed ID: 21232725
[TBL] [Abstract][Full Text] [Related]
19. Echocardiographic imaging of the Medtronic Micro Vascular Plug
Berry JM; Hiremath G; Heal E; Bass JL
Echocardiography; 2019 May; 36(5):944-947. PubMed ID: 31006919
[TBL] [Abstract][Full Text] [Related]
20. Use of the Medtronic Microvascular Plug 7Q for transcatheter closure of large patent ductus arteriosus in infants weighing less than 2.5 kg.
Nasef MA; Sullivan DO; Ng LY; Walsh KP; Oslizlok P; McCrossan B; Kenny D; Sathanandam S
Catheter Cardiovasc Interv; 2022 Apr; 99(5):1545-1550. PubMed ID: 35094486
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]