These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

124 related articles for article (PubMed ID: 38502722)

  • 21. The new Occlutech(®) patent ductus arteriosus occluder: Single centre experience.
    Boudjemline Y
    Arch Cardiovasc Dis; 2016; 109(6-7):384-9. PubMed ID: 26988839
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Distensibility of the ductus arteriosus in neonates and young infants undergoing transcatheter closure.
    Nagasawa K; Muneuchi J; Sugitani Y; Ezaki H; Doi H; Furuta T; Kobayashi M; Watanabe M
    Heart Vessels; 2022 Mar; 37(3):513-516. PubMed ID: 34406441
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Transcatheter closure of patent ductus arteriosus in under 6 kg and premature infants.
    Baspinar O; Sahin DA; Sulu A; Irdem A; Gokaslan G; Sivasli E; Kilinc M
    J Interv Cardiol; 2015 Apr; 28(2):180-9. PubMed ID: 25832591
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Percutaneous closure of patent ductus arteriosus in preterm infants.
    Rueda Núñez F; Avila Alvarez A; Fernández Trisac JL; Abelleira Pardeiro C
    Rev Esp Cardiol; 2010 Jun; 63(6):740-1. PubMed ID: 20515633
    [No Abstract]   [Full Text] [Related]  

  • 25. Catheter-based closure of the patent ductus arteriosus in preterm infants: considerations in the design of a randomized trial.
    Backes CH; Donovan JL; Slaughter JL
    J Perinatol; 2019 Nov; 39(11):1437-1438. PubMed ID: 31515502
    [No Abstract]   [Full Text] [Related]  

  • 26. Percutaneous closure of patent ductus arteriosus in premature infants: A French national survey.
    Malekzadeh-Milani S; Akhavi A; Douchin S; Dauphin C; Chalard A; Mauran P; Bouvaist H; Bonnet D; Boudjemline Y
    Catheter Cardiovasc Interv; 2020 Jan; 95(1):71-77. PubMed ID: 31609068
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Outcomes of transcatheter closure of patent ductus arteriosus with the off-label use of large occluders (≥16 mm).
    Kanabar K; Bootla D; Kaur N; Pruthvi CR; Krishnappa D; Santosh K; Guleria V; Rohit MK
    Indian Heart J; 2020; 72(2):107-112. PubMed ID: 32534682
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Overview of transcatheter patent ductus arteriosus closure in preterm infants.
    Almeida-Jones M; Tang NY; Reddy A; Zahn E
    Congenit Heart Dis; 2019 Jan; 14(1):60-64. PubMed ID: 30811790
    [TBL] [Abstract][Full Text] [Related]  

  • 29. [Transcatheter occlusion of patent ductus arteriosus in a preterm infant and review of literatures].
    Zhou K; Tang J; Hua Y; Shi X; Wang Y; Qiao L; Wang X; Mu D
    Zhonghua Er Ke Za Zhi; 2016 Jan; 54(1):43-6. PubMed ID: 26791923
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Morphologic characterization of the patent ductus arteriosus in the premature infant and the choice of transcatheter occlusion device.
    Philip R; Waller BR; Agrawal V; Wright D; Arevalo A; Zurakowski D; Sathanandam S
    Catheter Cardiovasc Interv; 2016 Feb; 87(2):310-7. PubMed ID: 26525611
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Institutional Trend in Device Selection for Transcatheter PDA Closure in Premature Infants.
    Guyon P; Duster N; Katheria A; Heyden C; Griffin D; Steinbergs R; Moreno Rojas A; Ratnayaka K; El-Said HG
    Pediatr Cardiol; 2022 Dec; 43(8):1716-1722. PubMed ID: 35430709
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Closure of the patent ductus arteriosus with the Amplatzer Duct Occluder II: a clinical experience.
    Karagöz T; Akin A; Ertuğrul I; Aykan HH; Alehan D; Ozer S; Ozkutlu S
    Acta Cardiol; 2012 Dec; 67(6):675-80. PubMed ID: 23393938
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Successful Percutaneous Treatment of an Embolized Patent Ductus Arteriosus Occluder Device.
    Barutçu S; Alizade E; Pala S
    Vasc Endovascular Surg; 2019 Apr; 53(3):264-266. PubMed ID: 30691353
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Further experience with catheter closure of patent ductus arteriosus using the new Amplatzer duct occluder in children.
    Thanopoulos BV; Eleftherakis N; Tzannos K; Stefanadis C; Giannopoulos A
    Am J Cardiol; 2010 Apr; 105(7):1005-9. PubMed ID: 20346321
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Different indications for transcatheter and surgical patent ductus arteriosus closure in preterm infants less than 2kg.
    Sallmon H; Berger F; Koehne P; Koestenberger M; Hansmann G; Opgen-Rhein B
    Int J Cardiol; 2018 Sep; 266():83. PubMed ID: 29887478
    [No Abstract]   [Full Text] [Related]  

  • 36. Transcatheter closure of moderate-to-large patent ductus arteriosus in infants using Amplatzer duct occluder.
    Wang JK; Wu MH; Lin MT; Chiu SN; Chen CA; Chiu HH
    Circ J; 2010 Feb; 74(2):361-4. PubMed ID: 20032563
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Transcatheter occlusion of the patent ductus arteriosus in infants: experimental testing of a new Amplatzer device.
    Bass JL; Wilson N
    Catheter Cardiovasc Interv; 2014 Feb; 83(2):250-5. PubMed ID: 24446324
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Transcatheter closure of patent ductus arteriosus using the AMPLATZER™ duct occluder II (ADO II).
    Gruenstein DH; Ebeid M; Radtke W; Moore P; Holzer R; Justino H
    Catheter Cardiovasc Interv; 2017 May; 89(6):1118-1128. PubMed ID: 28258658
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Patent ductus arteriosus in preterm infants: is early transcatheter closure a paradigm shift?
    Vali P; Lakshminrusimha S; Pelech A; Underwood M; Ing F
    J Perinatol; 2019 Nov; 39(11):1449-1461. PubMed ID: 31562396
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Initial clinical experience with the Medtronic Micro Vascular Plug™ in transcatheter occlusion of PDAs in extremely premature infants.
    Sathanandam S; Justino H; Waller BR; Radtke W; Qureshi AM
    Catheter Cardiovasc Interv; 2017 May; 89(6):1051-1058. PubMed ID: 27888552
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 7.