158 related articles for article (PubMed ID: 38505053)
1. Can a stapling device with bioabsorbable polyglycolic acid felt reduce intraoperative air leak?
Makino T; Matsumura T; Kono M; Anami Y
J Thorac Dis; 2024 Feb; 16(2):893-900. PubMed ID: 38505053
[TBL] [Abstract][Full Text] [Related]
2. Reduction of air leakage using linear staple device with bioabsorbable polyglycolic acid felt for pulmonary lobectomy.
Deguchi H; Tomoyasu M; Shigeeda W; Kaneko Y; Kanno H; Saito H
Gen Thorac Cardiovasc Surg; 2020 Mar; 68(3):266-272. PubMed ID: 31541348
[TBL] [Abstract][Full Text] [Related]
3. Anastomotic Leakage Using Linear Stapling Device with Pre-attached Bioabsorbable Polyglycolic Acid Felt After Laparoscopic Anterior Resection.
Yamamoto S; Kanai T; Osumi K; Yo K; Takano K; Tsutsui M; Nakanishi R; Yoshikawa Y; Kaneko Y; Nakagawa M
Anticancer Res; 2017 Dec; 37(12):7083-7086. PubMed ID: 29187499
[TBL] [Abstract][Full Text] [Related]
4. The utility of the Stapler with PGA sheet for pulmonary wedge resection: a propensity score-matched analysis.
Shigeeda W; Deguchi H; Tomoyasu M; Kaneko Y; Kanno H; Tanita T; Saito H
J Thorac Dis; 2019 Apr; 11(4):1546-1553. PubMed ID: 31179098
[TBL] [Abstract][Full Text] [Related]
5. Safety and efficacy of a novel linear staple device with bioabsorbable polyglicolic acid felt in laparoscopic colorectal surgery.
Naito M; Yamanashi T; Nakamura T; Miura H; Tsutsui A; Sato T; Watanabe M
Asian J Endosc Surg; 2017 Feb; 10(1):35-39. PubMed ID: 27491782
[TBL] [Abstract][Full Text] [Related]
6. [A device to prevent an air-leakage after a thoracoscopic surgery for spontaneous pneumothorax].
Minami K; Saito Y; Shomura Y; Imamura H
Kyobu Geka; 2003 Oct; 56(11):904-7. PubMed ID: 14579690
[TBL] [Abstract][Full Text] [Related]
7. Prospective randomized trial comparing buttressed versus nonbuttressed stapling in patients undergoing pulmonary lobectomy.
Takamochi K; Oh S; Miyasaka Y; Matsunaga T; Kitamura Y; Fukui M; Suzuki K
Thorac Cardiovasc Surg; 2014 Dec; 62(8):696-704. PubMed ID: 24875810
[TBL] [Abstract][Full Text] [Related]
8. Utility of the powered stapler for radical pulmonary resection: a propensity score-matched analysis.
Shigeeda W; Deguchi H; Tomoyasu M; Kudo S; Kaneko Y; Kanno H; Saito H
Surg Today; 2021 Apr; 51(4):582-588. PubMed ID: 33037476
[TBL] [Abstract][Full Text] [Related]
9. Maximum resistance pressure at the time of lung tissue rupture after porcine lung transection using automatic linear staplers with different reinforcement methods.
Takamori S; Takenaka T; Shimokawa M; Hashinokuchi A; Matsudo K; Nagano T; Kohno M; Miura N; Yoshizumi T
Surg Today; 2024 May; ():. PubMed ID: 38691222
[TBL] [Abstract][Full Text] [Related]
10. [Thoracoscopic partial lung resection using staplers and polyglycolic acid (PGA) felts in an 85-year-old patient].
Yoshiya K; Togashi K; Sato Y
Kyobu Geka; 1995 Sep; 48(10):833-5. PubMed ID: 7474581
[TBL] [Abstract][Full Text] [Related]
11. Usefulness of free pericardial fat pads as pledgets for air leaks in pulmonary resection.
Kameyama K; Ueshima Y; Ikebe S; Nakazono C; Urata Y; Okada S; Inoue M
Surg Today; 2023 Jan; 53(1):31-41. PubMed ID: 36376403
[TBL] [Abstract][Full Text] [Related]
12. Efficacy of the polyglycolic acid sheet for preventing anastomotic leakage in double-stapling technique anastomosis for left-sided colon or rectal cancer surgery: a propensity score-matched study.
Shibutani M; Fukuoka T; Iseki Y; Kasashima H; Maeda K
BMC Surg; 2023 May; 23(1):135. PubMed ID: 37198625
[TBL] [Abstract][Full Text] [Related]
13. Staple-line reinforcement with a new type of polyglycolic acid felt.
Kawamura M; Kase K; Sawafuji M; Watanabe M; Horinouchi H; Kobayashi K
Surg Laparosc Endosc Percutan Tech; 2001 Feb; 11(1):43-6. PubMed ID: 11269555
[TBL] [Abstract][Full Text] [Related]
14. The role of new staplers in reducing the incidence of air leak.
Marra A; Yankulov A
J Thorac Dis; 2023 Feb; 15(2):893-900. PubMed ID: 36910065
[TBL] [Abstract][Full Text] [Related]
15. Staplers versus hand-sewing for pulmonary lobectomy: randomized controlled trial.
Tantraworasin A; Seateang S; Bunchungmongkol N
Asian Cardiovasc Thorac Ann; 2014 Mar; 22(3):309-14. PubMed ID: 24585907
[TBL] [Abstract][Full Text] [Related]
16. Sutureless pneumostasis using polyglycolic acid mesh as artificial pleura during video-assisted major pulmonary resection.
Ueda K; Tanaka T; Jinbo M; Yagi T; Li TS; Hamano K
Ann Thorac Surg; 2007 Dec; 84(6):1858-61. PubMed ID: 18036899
[TBL] [Abstract][Full Text] [Related]
17. Fibrin glue and bioabsorbable felt patch for intraoperative intractable air leaks.
Miyamoto H; Futagawa T; Wang Z; Yamazaki A; Morio A; Sonobe S; Izumi H; Hosoda Y; Hata E
Jpn J Thorac Cardiovasc Surg; 2003 Jun; 51(6):232-6. PubMed ID: 12831236
[TBL] [Abstract][Full Text] [Related]
18. Patient and surgical factors influencing air leak after lung volume reduction surgery: lessons learned from the National Emphysema Treatment Trial.
DeCamp MM; Blackstone EH; Naunheim KS; Krasna MJ; Wood DE; Meli YM; McKenna RJ;
Ann Thorac Surg; 2006 Jul; 82(1):197-206; discussion 206-7. PubMed ID: 16798215
[TBL] [Abstract][Full Text] [Related]
19. Dissection of lung parenchyma using electrocautery is a safe and acceptable method for anatomical sublobar resection.
Ohtsuka T; Goto T; Anraku M; Kohno M; Izumi Y; Horinouchi H; Nomori H
J Cardiothorac Surg; 2012 May; 7():42. PubMed ID: 22554035
[TBL] [Abstract][Full Text] [Related]
20. Impact of powered circular stapler on anastomotic leak after anastomosis to the rectum: a propensity score matched study.
Vignali A; Gozzini L; Gasparini G; Calef R; Rosati R; Elmore U
Int J Colorectal Dis; 2023 Aug; 38(1):211. PubMed ID: 37561203
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]