These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

113 related articles for article (PubMed ID: 38508345)

  • 21. Deviation of femoral intramedullary alignment rod influences coronal and sagittal alignment during total knee arthroplasty.
    Haruta Y; Kawahara S; Tsuchimochi K; Hamasaki A; Hara T
    Knee; 2018 Aug; 25(4):644-649. PubMed ID: 29778655
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Referencing the center of the femoral head during robotic or computer-navigated primary total knee arthroplasty results in less femoral component flexion than the traditional intramedullary axis.
    Chalmers BP; Borsinger TM; Quevedo Gonzalez FJ; Vigdorchik JM; Haas SB; Ast MP
    Knee; 2023 Oct; 44():172-179. PubMed ID: 37672908
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Deviations in femoral joint lines using calipered kinematically aligned TKA from virtually planned joint lines are small and do not affect clinical outcomes.
    Nedopil AJ; Howell SM; Hull ML
    Knee Surg Sports Traumatol Arthrosc; 2020 Oct; 28(10):3118-3127. PubMed ID: 31768572
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Robotic-assisted total knee arthroplasty improves accuracy and precision compared to conventional techniques.
    Deckey DG; Rosenow CS; Verhey JT; Brinkman JC; Mayfield CK; Clarke HD; Bingham JS
    Bone Joint J; 2021 Jun; 103-B(6 Supple A):74-80. PubMed ID: 34053292
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Optimization of sagittal and coronal planes with robotic-assisted unicompartmental knee arthroplasty.
    Gaudiani MA; Nwachukwu BU; Baviskar JV; Sharma M; Ranawat AS
    Knee; 2017 Aug; 24(4):837-843. PubMed ID: 28579132
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Does Component Alignment Affect Patient Reported Outcomes following Bicruciate Retaining Total Knee Arthroplasty? An In Vivo Three-Dimensional Analysis.
    Peng Y; Arauz P; An S; Limmahakhun S; Klemt C; Kwon YM
    J Knee Surg; 2020 Aug; 33(8):798-803. PubMed ID: 31064018
    [TBL] [Abstract][Full Text] [Related]  

  • 27. The accuracy of intramedullary tibial guide of sagittal alignment of PCL-substituting total knee arthroplasty.
    Han HS; Kang SB; Jo CH; Kim SH; Lee JH
    Knee Surg Sports Traumatol Arthrosc; 2010 Oct; 18(10):1334-8. PubMed ID: 20454779
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Does computer-assisted surgery improve postoperative leg alignment and implant positioning following total knee arthroplasty? A meta-analysis of randomized controlled trials?
    Cheng T; Zhao S; Peng X; Zhang X
    Knee Surg Sports Traumatol Arthrosc; 2012 Jul; 20(7):1307-22. PubMed ID: 21732057
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Robotic arm-assisted bi-unicompartmental knee arthroplasty maintains natural knee joint anatomy compared with total knee arthroplasty: a prospective randomized controlled trial.
    Banger MS; Johnston WD; Razii N; Doonan J; Rowe PJ; Jones BG; MacLean AD; Blyth MJG
    Bone Joint J; 2020 Nov; 102-B(11):1511-1518. PubMed ID: 33135443
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Robotic-arm assisted total knee arthroplasty has a learning curve of seven cases for integration into the surgical workflow but no learning curve effect for accuracy of implant positioning.
    Kayani B; Konan S; Huq SS; Tahmassebi J; Haddad FS
    Knee Surg Sports Traumatol Arthrosc; 2019 Apr; 27(4):1132-1141. PubMed ID: 30225554
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Tibial component alignment after total knee arthroplasty with intramedullary instrumentation: a prospective analysis.
    Talmo CT; Cooper AJ; Wuerz T; Lang JE; Bono JV
    J Arthroplasty; 2010 Dec; 25(8):1209-15. PubMed ID: 19879723
    [TBL] [Abstract][Full Text] [Related]  

  • 32. CT Validation of Intraoperative Implant Position and Knee Alignment as Determined by the MAKO Total Knee Arthroplasty System.
    Sires JD; Wilson CJ
    J Knee Surg; 2021 Aug; 34(10):1133-1137. PubMed ID: 32131103
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Revision of partial knee to total knee arthroplasty with use of patient-specific instruments results in acceptable femoral rotation.
    Schotanus MGM; Thijs E; Boonen B; Kerens B; Jong B; Kort NP
    Knee Surg Sports Traumatol Arthrosc; 2018 Jun; 26(6):1656-1661. PubMed ID: 28785788
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Intra- and inter-observer reliability of implant positioning evaluation on a CT-based three-dimensional postoperative matching system for total knee arthroplasty.
    Watanabe S; Akagi R; Shiko Y; Ono Y; Kawasaki Y; Ohdera T; Ohtori S; Sasho T
    BMC Musculoskelet Disord; 2021 Apr; 22(1):363. PubMed ID: 33865360
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Restoring Tibial Slope and Sagittal Alignment of the Femoral Component in Unrestricted Kinematically Aligned Total Knee Arthroplasty Using Conventional versus Patient-Specific Instrumentation.
    Sadoghi P; Draschl A; Leitner L; Fischerauer S; Koutp A; Clar C; Leithner A; Klasan A
    J Knee Surg; 2024 Jan; 37(1):2-7. PubMed ID: 37734408
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Coronal femoral TKA position significantly influences in vivo patellar loading in unresurfaced patellae after primary total knee arthroplasty.
    Slevin O; Schmid FA; Schiapparelli FF; Rasch H; Amsler F; Hirschmann MT
    Knee Surg Sports Traumatol Arthrosc; 2017 Nov; 25(11):3605-3610. PubMed ID: 28653182
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Robot-assisted implantation improves the precision of component position in minimally invasive TKA.
    Kim SM; Park YS; Ha CW; Lim SJ; Moon YW
    Orthopedics; 2012 Sep; 35(9):e1334-9. PubMed ID: 22955398
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Intra- and interobserver reliability and agreement in three-dimensional computed tomography measurements of component positions after total knee arthroplasty.
    Yoshino K; Hagiwara S; Nakamura J; Tsukeoka T; Tsuneizumi Y; Ohtori S
    Knee; 2019 Oct; 26(5):1102-1110. PubMed ID: 31340892
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Navigated total knee arthroplasty: is it error-free?
    Chua KH; Chen Y; Lingaraj K
    Knee Surg Sports Traumatol Arthrosc; 2014 Mar; 22(3):643-9. PubMed ID: 24061715
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Robotic-assisted total knee arthroplasty improves implant position and early functional recovery for the knee with severe varus/valgus deformity.
    Yang Y; Jiang L; Zhou X; Zhou X; Chen H; Chen Z
    BMC Musculoskelet Disord; 2024 Jan; 25(1):92. PubMed ID: 38267884
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 6.