BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

163 related articles for article (PubMed ID: 38509154)

  • 21. Iterative metal artefact reduction (MAR) in postsurgical chest CT: comparison of three iMAR-algorithms.
    Aissa J; Boos J; Sawicki LM; Heinzler N; Krzymyk K; Sedlmair M; Kröpil P; Antoch G; Thomas C
    Br J Radiol; 2017 Nov; 90(1079):20160778. PubMed ID: 28830194
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Clinical evaluation of a commercial orthopedic metal artifact reduction tool for CT simulations in radiation therapy.
    Li H; Noel C; Chen H; Harold Li H; Low D; Moore K; Klahr P; Michalski J; Gay HA; Thorstad W; Mutic S
    Med Phys; 2012 Dec; 39(12):7507-17. PubMed ID: 23231300
    [TBL] [Abstract][Full Text] [Related]  

  • 23. The dosimetric impact of stabilizing spinal implants in radiotherapy treatment planning with protons and photons: standard titanium alloy vs. radiolucent carbon-fiber-reinforced PEEK systems.
    Müller BS; Ryang YM; Oechsner M; Düsberg M; Meyer B; Combs SE; Wilkens JJ
    J Appl Clin Med Phys; 2020 Aug; 21(8):6-14. PubMed ID: 32476247
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Accurate proton treatment planning for pencil beam crossing titanium fixation implants.
    Righetto R; Clemens LP; Lorentini S; Fracchiolla F; Algranati C; Tommasino F; Dionisi F; Cianchetti M; Schwarz M; Farace P
    Phys Med; 2020 Feb; 70():28-38. PubMed ID: 31954210
    [TBL] [Abstract][Full Text] [Related]  

  • 25. The influence of metal artefacts on the range of ion beams.
    Jäkel O; Reiss P
    Phys Med Biol; 2007 Feb; 52(3):635-44. PubMed ID: 17228110
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Reduction of CT Artifacts Using Polyetheretherketone (PEEK), Polyetherketoneketone (PEKK), Polyphenylsulfone (PPSU), and Polyethylene (PE) Reconstruction Plates in Oral Oncology.
    Lommen J; Schorn L; Sproll C; Haussmann J; Kübler NR; Budach W; Rana M; Tamaskovics B
    J Oral Maxillofac Surg; 2022 Jul; 80(7):1272-1283. PubMed ID: 35378095
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Low cervical vertebral CT value increased early subsidence of titanium mesh cage after anterior cervical corpectomy and fusion.
    Wang Z; Mei J; Feng X; Deng C; Tian X; Lv J; Sun L
    J Orthop Surg Res; 2022 Jul; 17(1):355. PubMed ID: 35842647
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Dosimetric impact of CT metal artifact reduction for spinal implants in stereotactic body radiotherapy planning.
    Li B; Huang J; Ruan J; Peng Q; Huang S; Li Y; Li F
    Quant Imaging Med Surg; 2023 Dec; 13(12):8290-8302. PubMed ID: 38106297
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Integrated Custom Composite Polyetheretherketone/Carbon fiber (PEEK/CF) Vertebral Body Replacement (VBR) in the Treatment of Bone Tumors of the Spine: A Preliminary Report From a Multicenter Study.
    Shen FH; Gasbarrini A; Lui DF; Reynolds J; Capua J; Boriani S
    Spine (Phila Pa 1976); 2022 Feb; 47(3):252-260. PubMed ID: 34310537
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Three-Dimensional Hounsfield Units Measurement of Pedicle Screw Trajectory for Predicating Screw Loosening in Lumbar Fusion Surgery.
    Zhao H; Wang YJ; Wang RG; Liu D; Duan YQ; Liu YJ; Zeng YH; Zhao QP; Zhang ZP
    Clin Interv Aging; 2023; 18():485-493. PubMed ID: 37008803
    [TBL] [Abstract][Full Text] [Related]  

  • 31. The association between lower Hounsfield units of the upper instrumented vertebra and proximal junctional kyphosis in adult spinal deformity surgery with a minimum 2-year follow-up.
    Duan PG; Mummaneni PV; Rivera J; Guinn JMV; Wang M; Xi Z; Li B; Wu HH; Ames CP; Burch S; Berven SH; Chou D
    Neurosurg Focus; 2020 Aug; 49(2):E7. PubMed ID: 32738804
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Reduction of metallic coil artefacts in computed tomography body imaging: effects of a new single-energy metal artefact reduction algorithm.
    Kidoh M; Utsunomiya D; Ikeda O; Tamura Y; Oda S; Funama Y; Yuki H; Nakaura T; Kawano T; Hirai T; Yamashita Y
    Eur Radiol; 2016 May; 26(5):1378-86. PubMed ID: 26271621
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Metallic implants and CT artefacts in the CTV area: Where are we in 2020?
    Rousselle A; Amelot A; Thariat J; Jacob J; Mercy G; De Marzi L; Feuvret L
    Cancer Radiother; 2020 Oct; 24(6-7):658-666. PubMed ID: 32859465
    [TBL] [Abstract][Full Text] [Related]  

  • 34. What is the role of CT-based Hounsfield unit assessment in the evaluation of bone mineral density in patients undergoing 1- or 2-level lumbar spinal fusion for degenerative spinal pathologies? A prospective study.
    Viswanathan VK; Shetty AP; Rai N; Sindhiya N; Subramanian S; Rajasekaran S
    Spine J; 2023 Oct; 23(10):1427-1434. PubMed ID: 37271374
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Contouring practices and artefact management within a synthetic CT-based radiotherapy workflow for the central nervous system.
    Rossi E; Emin S; Gubanski M; Gagliardi G; Hedman M; Villegas F
    Radiat Oncol; 2024 Feb; 19(1):27. PubMed ID: 38424642
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Comparison of different CT metal artifact reduction strategies for standard titanium and carbon-fiber reinforced polymer implants in sheep cadavers.
    Huber FA; Sprengel K; Müller L; Graf LC; Osterhoff G; Guggenberger R
    BMC Med Imaging; 2021 Feb; 21(1):29. PubMed ID: 33588781
    [TBL] [Abstract][Full Text] [Related]  

  • 37. The appearance and effects of metallic implants in CT images.
    Kairn T; Crowe SB; Fogg P; Trapp JV
    Australas Phys Eng Sci Med; 2013 Jun; 36(2):209-17. PubMed ID: 23760920
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Monte Carlo dose in a prosthesis phantom based on exact geometry vs streak artefact contaminated CT data as benchmarked against Gafchromic film measurements.
    Ade N; Oderinde OM; du Plessis FCP
    Phys Med; 2018 Oct; 54():94-102. PubMed ID: 30337015
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Comparison of treatment plan quality among MRI-based IMRT with a linac, MRI-based IMRT with tri-Co-60 sources, and VMAT for spine SABR.
    Choi CH; Kim JH; Kim JI; Park JM
    PLoS One; 2019; 14(7):e0220039. PubMed ID: 31329641
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Carbon Fiber/Polyether Ether Ketone (CF/PEEK) Implants Allow for More Effective Radiation in Long Bones.
    Laux CJ; Villefort C; Ehrbar S; Wilke L; Guckenberger M; Müller DA
    Materials (Basel); 2020 Apr; 13(7):. PubMed ID: 32283675
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 9.