These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

171 related articles for article (PubMed ID: 38514200)

  • 1. Twenty-four hour continuous transvenous temporary right ventricular pacing in healthy horses.
    Avison A; Gelzer AR; Reef VB; Wulster Bills KB; de Solis CN; Kraus MS; Slack J; Stefanovski D; Deacon LJ; Underwood C
    J Vet Intern Med; 2024; 38(3):1751-1764. PubMed ID: 38514200
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Transvenous cardiac pacing.
    Côté E; Laste NJ
    Clin Tech Small Anim Pract; 2000 Aug; 15(3):165-76. PubMed ID: 11109718
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Permanent transvenous pacemaker implantation in an Ibizan hound cross with persistent atrial standstill.
    MacAulay K
    Can Vet J; 2002 Oct; 43(10):789-91. PubMed ID: 12395764
    [TBL] [Abstract][Full Text] [Related]  

  • 4. The Use of Subcostal Echocardiographic Views to Guide the Insertion of a Right Ventricular Temporary Transvenous Pacemaker-Description of the Technique.
    Sjaus A; Fayad A
    J Cardiothorac Vasc Anesth; 2019 Oct; 33(10):2797-2803. PubMed ID: 30770181
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Transvenous pacing implantation: techniques, tips, and lessons learned along the way.
    Estrada AH; Maisenbacher HW; Jones AE; Prošek R; Kleman ME; Bryant RM
    J Vet Cardiol; 2019 Apr; 22():51-64. PubMed ID: 30661842
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Inadvertent Left Ventricle Endocardial or Uncomplicated Right Ventricular Pacing: How to Differentiate in the Emergency Department.
    Velibey Y; Yaylak B; Guvenc TS; Cinier G; Kalenderoglu K; Guzelburc O; Yildirimturk O
    J Emerg Med; 2018 May; 54(5):e91-e95. PubMed ID: 29523425
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Transthoracic echo-guided pacemaker implantation reduces fluoroscopic use in dogs.
    Porciello F; Marchesi MC; Birettoni F; Spina F; Knafelz P; Bufalari A; Rishniw M; Moise NS; Caivano D
    Vet J; 2021 Nov; 277():105762. PubMed ID: 34655788
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Noninvasive transthoracic temporary cardiac pacing in dogs.
    DeFrancesco TC; Hansen BD; Atkins CE; Sidley JA; Keene BW
    J Vet Intern Med; 2003; 17(5):663-7. PubMed ID: 14529132
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Dual-chamber pacing using a hybrid transvenous and leadless pacing approach.
    Nona P; Altawil M; Khan E; Maskoun W
    Pacing Clin Electrophysiol; 2021 Apr; 44(4):751-754. PubMed ID: 33559285
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Electroanatomic mapping-guided localization of alternative right ventricular septal pacing sites in children.
    Silvetti MS; Battipaglia I; Pazzano V; Saputo FA; Ravà L; Ammirati A; Calvieri C; Ciani M; Drago F
    Pacing Clin Electrophysiol; 2018 Sep; 41(9):1204-1211. PubMed ID: 29989185
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Impact of temporary right ventricular pacing from different sites on echocardiographic indices of cardiac function.
    Alhous MH; Small GR; Hannah A; Hillis GS; Broadhurst P
    Europace; 2011 Dec; 13(12):1738-46. PubMed ID: 21764814
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Implantation of a permanent transvenous pacing catheter in a horse with complete heart block and syncope.
    Reef VB; Clark ES; Oliver JA; Donawick WJ
    J Am Vet Med Assoc; 1986 Aug; 189(4):449-52. PubMed ID: 3759616
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Prospective evaluation of feasibility and electrophysiologic and echocardiographic characteristics of left bundle branch area pacing.
    Vijayaraman P; Subzposh FA; Naperkowski A; Panikkath R; John K; Mascarenhas V; Bauch TD; Huang W
    Heart Rhythm; 2019 Dec; 16(12):1774-1782. PubMed ID: 31136869
    [TBL] [Abstract][Full Text] [Related]  

  • 14. [Temporary emergency cardiac pacing under continuous echocardiographic control. Feasibility and safety of the procedure without using fluoroscopy].
    Pinneri F; Mazza A; Garzaro L; Galeazzi M; De Felice F; Russo M; Dottori M; Madama G; Recanzone P; Kamal N; Rizzotti M; Panella S; Valentini G; Tos GG
    Ital Heart J Suppl; 2003 Jul; 4(7):581-6. PubMed ID: 14558286
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Pacing of the interventricular septum versus the right ventricular apex: a prospective, randomized study.
    Domenichini G; Sunthorn H; Fleury E; Foulkes H; Stettler C; Burri H
    Eur J Intern Med; 2012 Oct; 23(7):621-7. PubMed ID: 22939807
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Right ventricular apex versus right ventricular outflow tract pacing: prospective, randomised, long-term clinical and echocardiographic evaluation.
    Lewicka-Nowak E; Dabrowska-Kugacka A; Tybura S; Krzymińska-Stasiuk E; Wilczek R; Staniewicz J; Swiatecka G; Raczek G
    Kardiol Pol; 2006 Oct; 64(10):1082-91; discussion 1092-3. PubMed ID: 17089240
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Electrocardiographic follow-up of biventricular pacemakers.
    Barold SS; Herweg B; Giudici M
    Ann Noninvasive Electrocardiol; 2005 Apr; 10(2):231-55. PubMed ID: 15842437
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Accelerated graft dysfunction in heart transplant patients with persistent atrioventricular conduction block.
    Lee W; Tay A; Walker BD; Kuchar DL; Hayward CS; Spratt P; Subbiah RN
    Europace; 2016 Dec; 18(12):1837-1841. PubMed ID: 26847073
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Atrioventricular sequential pacing using transesophageal atrial pacing in combination with a temporary DDD pacemaker for atrial tracking and ventricular pacing.
    Roth JV; Huertas R
    J Cardiothorac Vasc Anesth; 1995 Jun; 9(3):255-8. PubMed ID: 7669956
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Use of transcutaneous external pacing during transvenous pacemaker implantation in dogs.
    Noomanová N; Perego M; Perini A; Santilli RA
    Vet Rec; 2010 Aug; 167(7):241-4. PubMed ID: 20710031
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.