These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

107 related articles for article (PubMed ID: 38515414)

  • 1. [Construction and stability analysis of finite element model for spinal canal reconstruction with miniplates fixation].
    Chen JM; Liu GY; Huang WQ; Lian ZH; Zhang EL; Zhao JN
    Zhongguo Gu Shang; 2024 Mar; 37(3):271-7. PubMed ID: 38515414
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Effect of Percutaneous Endoscopic Lumbar Foraminoplasty of Different Facet Joint Portions on Lumbar Biomechanics: A Finite Element Analysis.
    Yu Y; Zhou Q; Xie YZ; Wang XL; Fan XH; Gu DW; Huang X; Wu WD
    Orthop Surg; 2020 Aug; 12(4):1277-1284. PubMed ID: 32643308
    [TBL] [Abstract][Full Text] [Related]  

  • 3. [Biomechanical analysis of miniplate fixation systems in restorative laminoplasty for spinal canal reconstruction].
    Chen J; Liu G; Bao T; Bai T; Zhang E; Zhao J
    Nan Fang Yi Ke Da Xue Xue Bao; 2023 Mar; 43(3):331-339. PubMed ID: 37087576
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Biomechanical evaluation of modified and traditional cortical bone trajectory technique on adjacent segment degeneration in transforaminal lumbar interbody fusion-finite element analysis.
    Tuoheti A; Xiao Y; Wang Y; Maimaiti A; Zhang R; Kahaer A; Tuoheti A; Wu X; Rexiti P
    BMC Musculoskelet Disord; 2024 Jan; 25(1):7. PubMed ID: 38166794
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Biomechanics of extreme lateral interbody fusion with different internal fixation methods: a finite element analysis.
    Li XH; She LJ; Zhang W; Cheng XD; Fan JP
    BMC Musculoskelet Disord; 2022 Feb; 23(1):134. PubMed ID: 35139843
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Biomechanical investigation of the hybrid lumbar fixation technique with traditional and cortical bone trajectories in transforaminal lumbar interbody fusion: finite element analysis.
    Huang Y; Maimaiti A; Tian Y; Li Z; Kahaer A; Rexiti P
    J Orthop Surg Res; 2023 Jul; 18(1):549. PubMed ID: 37525283
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Biomechanical Effect of L
    Cai XY; Sun MS; Huang YP; Liu ZX; Liu CJ; Du CF; Yang Q
    Orthop Surg; 2020 Jun; 12(3):917-930. PubMed ID: 32476282
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Biomechanical changes of degenerated adjacent segment and intact lumbar spine after lumbosacral topping-off surgery: a three-dimensional finite element analysis.
    Cao L; Liu Y; Mei W; Xu J; Zhan S
    BMC Musculoskelet Disord; 2020 Feb; 21(1):104. PubMed ID: 32061252
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Biomechanical characteristics of a novel interspinous distraction fusion device in the treatment of lumbar degenerative diseases: a finite element analysis.
    Chen M; Deng J; Bao L; Jia P; Feng F; Shi G; Tang H; Chen H
    BMC Musculoskelet Disord; 2023 Dec; 24(1):944. PubMed ID: 38057738
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Biomechanical evaluation of different oblique lumbar interbody fusion constructs: a finite element analysis.
    Xu Z; Zheng Q; Zhang L; Chen R; Li Z; Xu W
    BMC Musculoskelet Disord; 2024 Jan; 25(1):97. PubMed ID: 38279094
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Biomechanical evaluation of a new total posterior-element replacement system.
    Wilke HJ; Schmidt H; Werner K; Schmölz W; Drumm J
    Spine (Phila Pa 1976); 2006 Nov; 31(24):2790-6; discussion 2797. PubMed ID: 17108830
    [TBL] [Abstract][Full Text] [Related]  

  • 12. [Effects of posterior lumbar spinal fusion on the stability of unstable lumbar segment and biomechanical properties of adjacent segments: a finite element study].
    Fei Q; Zhao F; Yang Y; Li D; Li J; Wang Q; Lin J; Yan H; Wang B
    Zhonghua Yi Xue Za Zhi; 2015 Dec; 95(45):3681-6. PubMed ID: 26849932
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Does the anterior column realignment technique influences the stresses on posterior instrumentation in sagittal imbalance correction? A biomechanical, finite-element analysis of L5-S1 ALIF and L3-4 lateral ACR.
    Panico M; Bertoli M; Villa TMT; Galbusera F; Messori M; La Maida GA; Misaggi B; Gallazzi E
    Spine Deform; 2023 Jan; 11(1):41-47. PubMed ID: 35999490
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Biomechanical Evaluation of Oblique Lumbar Interbody Fusion with Various Fixation Options: A Finite Element Analysis.
    Song C; Chang H; Zhang D; Zhang Y; Shi M; Meng X
    Orthop Surg; 2021 Apr; 13(2):517-529. PubMed ID: 33619850
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Transforaminal lumbar interbody fusion: the effect of various instrumentation techniques on the flexibility of the lumbar spine.
    Harris BM; Hilibrand AS; Savas PE; Pellegrino A; Vaccaro AR; Siegler S; Albert TJ
    Spine (Phila Pa 1976); 2004 Feb; 29(4):E65-70. PubMed ID: 15094547
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Biomechanical comparison of single-level posterior versus transforaminal lumbar interbody fusions with bilateral pedicle screw fixation: segmental stability and the effects on adjacent motion segments.
    Sim HB; Murovic JA; Cho BY; Lim TJ; Park J
    J Neurosurg Spine; 2010 Jun; 12(6):700-8. PubMed ID: 20515358
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Biomechanical Changes of Adjacent and Fixed Segments Through Cortical Bone Trajectory Screw Fixation versus Traditional Trajectory Screw Fixation in the Lumbar Spine: A Finite Element Analysis.
    Zhang L; Li HM; Zhang R; Zhang H; Shen CL
    World Neurosurg; 2021 Jul; 151():e447-e456. PubMed ID: 33895371
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Oblique lateral interbody fusion with internal fixations in the treatment for cross-segment degenerative lumbar spine disease (L2-3 and L4-5) finite element analysis.
    Zhang S; Zhang Y; Huang L; Zhang S; Lu C; Liu Z; Kang C; Wang Z
    Sci Rep; 2023 Oct; 13(1):17116. PubMed ID: 37816744
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Effect of the Total Facet Arthroplasty System after complete laminectomy-facetectomy on the biomechanics of implanted and adjacent segments.
    Phillips FM; Tzermiadianos MN; Voronov LI; Havey RM; Carandang G; Renner SM; Rosler DM; Ochoa JA; Patwardhan AG
    Spine J; 2009; 9(1):96-102. PubMed ID: 18440280
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Biomechanical evaluation of a new pedicle screw-based posterior dynamic stabilization device (Awesome Rod System)--a finite element analysis.
    Chen CS; Huang CH; Shih SL
    BMC Musculoskelet Disord; 2015 Apr; 16():81. PubMed ID: 25880231
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.